Refine
Estimated Years 1960-1969Clear
16,810 results foundRefine Search
MOTOR CONTROL FOR SPECIFIC APPLICATIONS Automatic Transfer Panels WHEN ORDERING SPECIFY 267 3 S|| ill Catalog number A-C NORMAL POWER SUPPLY--Magnetically held no. of Poles 2 3 4 Maximum Ampere Rating 0Tungsten Incandescent Lamp Loads Open Enclosed Open or Enclosed 8 20 18 12 30 27 12 030 030 30 50 45 60 100 90 12Q 150 135 240 300 270 480 600 540 8 20 18 12 30 27 30 50 45 60 100 90 120 . 150 135 240 300 270 480 600 540 8 20 18 12 30 27 30 50 45 60 100 90 120 150 135 A-c Emergency Supply 110 to 600 Volts NEMA General Purpose Watertight Size Open Enclosure Enclosure NEMA 1 NEMA 4 Cat.
Document image
refid# JNvEGNNwqBkvdnrnadKmEgQnv1 page
'i C,, Industrial Hygiene Digest INDUSTRIAL HEALTH NEWS LITERATURE ABSTRACTS MEDICAL ENGINEERING CHEMICAL TOXICOLOGICAL LEGAL JUNE, 1967 (Vol. 31, No. 6) INDUSTRIAL HYGIENE FOUNDATION MELLON INSTITUTE 4400 lUTH AVENUE PITTSBUBGH, PA. 13213 I PLAINTIFF'S 1 | EXHIBIT 1I --s y .
Document imageDocument imageDocument imageDocument image
refid# vV2VZonmwZpRQD7Qn4Q5KZDGm34 pages
GEORGIA-PACIFIC CORPORATION BEGTWALL GYPSUM DIVISION R&D REPORT FOR FIRST 6 MONTHS OF 1965 PLAINTIFF'S EXHIBIT GP-1325 TABLE OF CONTENTS PAGE NOp Foreword - -- -- -- -- -- -- -- -- - -- -- -- -- Market Performance of New Products, Patent Data- - ----- Distribution of R&D Expense- ---------------- 1 2 3 PROJECTS COMPLETED New Glass Fiber- --------------------- 4 Joint System Textures- ------------------ 4 Synthetic Gypsum --------------------- 4 Joint System Formula Revisions -------------- 5 Two Hour Fire Rated Incombustible Floor-Ceiling with l/2" Firestop ------------------------- 6 One Hour Fire RatedWood Floor-Ceiling with 1/2" Firestop- 6 Two Hour Fire Rated Metal Stud Partition --------- 7 Fire R.ated Lath & Plaster Partition- - -- -- -- -- -- 7 Metal Stud Partition for 2 Hour Rating ---------- 8 Wood Stud Partition for One Hour Rating- ---- ----- - - - 8 Gypsum Stud Partition for One Hour Rating- -------- 8 Competitive Thincoat Plaster Survey- ----------- 9 Radiant Heating Panel- ------------------ 10 Pilot Fire Testing -------------------- 10 Assistance to Legal Department -------------- 11 PROJECTS NEARING COMPLETION Vinyl Joint Compound ------------------Ready Mix Joint Compound ----------------Evaluation of Dens-Cote Tape --------------Dens-Cote over Masonry -----------------New Grainbcard Products- ----------------- 12 12 13 13 14 PROJECTS UNDERWAY Two-Coat Veneer Plaster- ----------------- 15 Dens-Cote Radiant Heating System ------------ 15,16,17 Prepared Trowel Finish Plaster -------------- 18 Particle Size Studies- ------------------ 18 Gypsum Acoustical Tile ------------------ 18 Sound Testing Program- ------------------ 19 Gypsum Exposed to High Temperatures- ----------- 19 Cooperative Research with Johns-Manvilie --------- 20 Pre-Coated Wallboard ------------------- 21 Lightweight 5/8" Firestop- ---------------- 21 Reduce Glass Fiber in 5/8" Firestop ----------- 22 Firestop Tile Backer ------------------- 22 One Hour Fire Rated Partition with l/2" Firestop ----- 22,23 SUMMARY------------------------------------------------------------------------------------- ------------------------- 24,25 SGP 0015222 FOREWORD This report covers the activities of the Research Department for the six months ending June 30, 1965.
Document imageDocument imageDocument imageDocument image
refid# 7dqgo8xeD62dpmE1KrkpYDOa26 pages
PAOLI, PENNSYLVANIA April 19, 1965 To: All Regional Sales Managers All Area Sales Managers All Salesmen Cc: Mr.
Document imageDocument imageDocument imageDocument image
refid# gaB5Oayzb1ZGVDqea6JOxzDZ96 pages
DECEIVED or'; NO. 94-CI-10078 BARON & BUDD IN RE: ASBESTOS LITIGATION IN THE DISTRICT COURT BEXAR COUNTY, TEXAS 285TH JUDICIAL DISTRICT DEFENDANT.
Document imageDocument imageDocument imageDocument image
refid# QJ111ZNvNVz5yr9xLY3aL3kRv57 pages
ao, 1963 General dales Mr. v. jJat>cy J-4 CONTiOCT May 9 A* A.
Document imageDocument image
refid# oMaa5brr9JOonGq698Oq8ZbMD2 pages
January, 1966 SUMMARY SHEET ACTUAL PRODUCT COS?
Document imageDocument imageDocument imageDocument image
refid# VJVBND31nMzwZebVBpvbr67r420 pages
ASBESTOS TEXTILES H.
Document image
refid# G5OnyBpGwjB0jz86KBQj68Jg41 page
CONFIDENTIAL Division Headquarters December 28, 1961 FDA # 54 PLAINTIFFS - EXHIBITS^ JMMC-244 TO: 322-S, 321-S, 12, 1071 PERSPECTIVE It is salutary we feel, to step back from the heat and action of the day's battle and view your adversary long range.
Document imageDocument imageDocument image
refid# rX4GvDRK99z4OMqww2572zME3 pages
438 CHAPTER 30 put from that panel.
Document image
refid# KKdwJeyovDnBn9OnzGXdBOqr1 page
t * I t i 492 CHAPTER 33 1960 Guide are not always known, another convenient method of ex pressing the relation of Equation 5 is as follows: 100(0, - CQ/2) Percent excess air N, X 0.264 - (Oi -- CO/2) (7) As measurement standards for gaseous fuels are almost universally expressed in cubic feet, Equation 8 may be em ployed for computing excess air on a percentage baas for Percent excess air (V - CO*) x ioop- CO, (8) where V = ultimate carbon dioxide, percent of flue gases result ing from perfect combustion.
Document image
refid# NO2L8Roz2qzkx3b5kbyGLa3g1 page
626 CHAPTER 42 1960 Guide OCW POINT AT ATMOSPHERIC PRESSURE - F Fig. 11....
Document image
refid# JrayxeMk0ZxZev79zz3LQ3Xav1 page
696 CHAPTER 49 1960 Guide Table 7....
Document image
refid# J3BJ4KzyXY7w55vRqLqObevK61 page
768 CHAPTER 56 1960 Guide FRICTION LOSS IN HEAD IN LBS.
Document image
refid# e5wKx6nqdEamRMeaD8mBL31vy1 page
136 Air Conditioning National Heater Company, Inc. 2475 Doswell Avenue St.
Document image
refid# zo1M5a285x1awy8Eap5k1rJxR1 page