also increase the efficiency of grooved drums For smooth-faced drums, proper direction of lay of rope for specified winding conditions further helps ensure uniform winding The head sheave groove should be checked for poor alignment, worn bearings, broken flanges, and size and shape of the groove at intervals of two or three months, depending on the amount of usage Proper groove size and shape are especially necessary when a new rope is installed Excessive sheave wear and its bad effects on the life of a rope often result from use of sheave or liner material unsuitable for the pressure of the rope If the radial pressure of a 6 x 19 rope exceeds 900 psi, a harder matenal than cast steel, such as manganese steel, is more suitable Lubncation Regular application of a suitable lubricant to wire hoisting rope prevents corrosion, wear from friction, and drying out of the core Thm lubricants, which are fluid at normal temperatures and are fortified with polar addi tives and rust inhibitors, can penetrate the rope and also afford good protecbon even un der wet operating conditions Ropes should be dry, when lubricant is applied, so that moisture will not be entrapped by the lubri cant Thm lubricants can be applied by hand, but the best arrangement is to provide some means of dripping them on the rope, or using a spray device to apply the proper quantity automatically Periodic monthly cleaning, done m mine shafts, eliminates dirt, abrasive particles, and corrosion-producing moisture Cleaning fluids should not be used because of their detri mental effect on the core lubricant Light oils are sometimes used to loosen the coating of lubricant and harmful materials A com pressed air or steam jet (or other mechanical method) cleans a rope effectively and thor oughly Overloading Overloading may occur in the operation of most types of hoisting equipment For ex ample, it is difficult to estimate the load within 25 percent when making a lift with a crane, and m many instances a load is under- TABLE 26-H NUMBER AND SPACING OF CLIPS FOR ROPES OF VARIOUS SIZES Diameter of tope (m ) V, V.
Document image
refid# emgEVQRpknODYqZ13Q03zdEx41 page
26--Ropes, Chains, and Slings The general strength and working load limits of alloy steel chain are not altered appreciably by low atmospheric temperatures Chain slings should preferably be pur chased complete from the manufacturer and, whenever repairs are required, should be sent back to him Hooks and attachments As a general rule, hooks, nngs, oblong links, pear-shaped links, coupling links, and other attachments should be made of the same, or equivalent, heat-treatable allov steel as the chain itself In most cases, attachments will be installed on the chain by the chain manufacturer, who will then heat-treat and proof-test the assembly If emergency conditions make it necessary for the user to replace an attachment, he should select the grade and size with extreme care High-strength, heat-treatable alloy con necting links of the same analysis type as that used by the chain manufacturer should be employed Unalloyed carbon-steel hooks, repair links, nngs, pear-shaped links, and other attach ments should not be used Homemade or makeshift bolts, rods, shackles, hooks without safety catches, or other attachments should never be used Standard items produced from alloy steel include sling hooks, grab hooks, foundry hooks, grab links, nngs, oblong links, pearshaped links, and repair links All such attachments used with the recommended cham size provide a safety factor equal to or greater than that of alloy cham itself Dimen sional specifications for these attachments will vary somewhat with the individual manufac turer Many injunes have resulted when em ployees have caught their fingers between the hook attachment and the load To prevent such injuries, handles can be attached to the assembly hook or end attachment To in crease operating efficiency, handles are also frequently used on large hooks, master links, and other attachments Handles should be welded to the attach ment pnor to heat treatment Welding heattreated attachments is not recommended un less the entire attachment is heat-treated again after welding The weldments should 732 TABLE 26-K MAXIMUM ALLOWABLE WEAR AT ANY POINT OF LINK Cham size (in ) V Vs V2 Vb Vb Vb 1 1 Vs 1 Vb IVb IVi IVb Maximum allowable wear (m) Vab Vbb Vab Vt* Vm "/ab Via Vm Vb Vm Via "/m be inspected critically for possible zones of high-stress concentration, caused by welding, that would lower the strength of the entire attachment Inspection Most of the causes of chain failures can be detected before failure occurs if the proper inspection procedure is followed A good inspection plan provides for two inspections, one daily by the personnel using the chain, and the other biannually or oftener by a trained man from the mechanical depart ment The former should be able to detect those links and hooks which have become vis ibly unsafe because of overloading, faulty rig ging, or other unsafe practices The latter should be an experienced person who has the authority to remove damaged assemblies from service for reconditioning or replacement A link-by-link inspection should be made to detect the following 1 Bent links 2 Cracks m weld areas, in shoulders, or in any other section of link 3 Tranverse nicks and gouges 4 Corrosion pits 5 Elongation caused by stretching can only
Document image
refid# YrkXbxmJaBEKqNbVr9ZaqnVdN1 page
My , im iSA'.V .A ^ Mr.
Document image
refid# reLKL7x5BJDZOrGLO6X50dJD71 page
32--Cold Forming of Metals Fic 32--30 --Jaws on pneumatic unloader grip finished part and remove it from die area on up stroke of press slide Pneumatically powered cylinders operat ing sweeps or lockout pins and tuned with the upstroke of the press are more effective than air jets for removal of large and heavy pieces For safety, when jams must be cleared or tryout operations performed, the pneumatic equipment should have a valve to shut off the flow of air and bleed any residual air pressure between valve and cylinders Clamp and pan shuttle extractors are used on presses of all sizes Pivoting or straight line clamps grip the part and remove it from the die area to a pallet, bin, or conveyor for 1 9 HOIXJ use MHO* ftOUHO STOCK - 8TUU ALUtttmm MUSS 0a 17/64 INCH OMM HOLS TO ACCMPT J/6-16 Mt TAP Fic 32-31 --A multi-onfice air ejector nozzle de signed for noise reduction 890 further processing A pan shuttle (Fig 32-- 32) catches the piece as it is stripped from the upper die by knockout pms or other means and removes it from the die area While some extractors are actuated mechan ically by connection with the press slide or shafting, independently powered extractors (Fig 32-30) are used more frequently be cause they are more versatile and can be used with several presses Every independently powered extractor should be interlocked with the press control circuit so that the press cannot operate unless the extractor is in "home" or "out" position Die Handling All mechanical, hydraulic, or pneumatic power presses use some type of die in their point of operations The heavy die, in turn, must be changed periodically Die handling produces its share of injuries too Dies are generally precision tools and deserve to be treated as such They may weigh from a few pounds to several tons, and, in addition, many of them have razor-sharp edges both inside and out If it is dropped, not only may the die be damaged, but the hand or foot it contacts will suffer Too many companies have inadequate die handling equipment, and too frequently they allow manual handlmg and carrying of smaller dies All dies should be transported to and from the die storage area on either a die table, truck, or appropriately rated hoist, unless the die is truly small and light enough to be car ried m one hand Dies weighing up to about 100 lb can gen erally be handled without lifting apparatus only if proper die trucks are provided (Fig 32-33) These trucks should have elevating tables which are adjustable to the heights of storage shelves and press bolster plates Dies should be earned at the lowest elevation of the truck Rollers or balls mounted in the top surface of the table will aid in sliding the die on or off the truck Heavy dies require more equipment for safe handlmg Because they are often lifted and moved by hoists, these dies should have tapped holes and eye bolts (or hooks), drilled holes and pins, chain slots, cast lugs in lower shoes, or clamping lugs to facilitate hookup
Document image
refid# RwMOOny9jBZ0LROgMJQQbwXE1 page
CAUSE NO. 94-CI-10078 IN RE: ASBESTOS LITIGATION IN THE DISTRICT COURT OF BEXAR COUNTY, TEXAS DEFENDANT MAREMONT CORPORATION'S FIRST AMENDED OBJECTIONS, ANSWERS, AND RESPONSES TO PLAINTIFFS' MASTER INTERROGATORIES AND REQUESTS FOR PRODUCTION PROPOUNDED TO DEFENDANT COMES NOW, Defendant Maremont Corporation ("Maremont"), and makes and files its First Amended Objections, Answers, and Responses to Plaintiffs' Master Interrogatories and Requests for Production Propounded to Defendant ("discovery requests").
Document imageDocument imageDocument imageDocument image
refid# mB83VNa66OqvxZ1Ye72J74bdJ158 pages
MTC 013908 rP&&/T<P November 23, 1970 F.
Document imageDocument imageDocument imageDocument image
refid# yqnBz71xLBRGLonRmL2yaM4d33 pages
I .
Document imageDocument imageDocument imageDocument image
refid# 6wN2XpkGz6kLO4EqBBp87ODy112 pages
Document image
refid# Jv8e2KY1v64mD3D304BJDvawB1 page
Document image
refid# peo30ME7LEQKbyXjkZm074a8X1 page
TABLE 36-A A GUIDE TO VENTILATION RATES FOR TYPICAL INDUSTRIAL EQUIPMENT Federal, State, or Local Regulations Should Be Followed Where Higher Ventilation Rates Are Required Operation Abrasive blast rooms (sand, grit, or shot) Abrasive blast cabinets Asbestos Carding Spool winding Type of Hood Ventilation Air Flow Usual Transport Velocity (fpm) Tight enclosure with air inlets (usually in roof) Tight enclosure with access open ings 60-100 fpm downdraft (long rooms of tunnel proportions 100 fpm crossdraft) 20 air changes per minute but not less than 500 fpm through all openings 3.500 3,500 Enclosure Local hoods 800 elm per machine SO cfm per spool 3,000 3,000 Bagging Open bag top Barrels-Drums (filling or removing matenal by scoop) Booth or enclosure (provide spillage hopper) Local hood Paper bags-- TOO cfm per sq ft open area Cloth bags-200 cfm per sq ft open area 100 cfm/sq ft of container cross section 3.500 3.500 3,500 Booth 100 fpm at face 3,500 Belt conveyors Hood at transfer point Belt speeds less than 200 fpm--350 cfm per foot of belt width, but not less than 150 fpm through open area Belt speeds over 200 fpm--500 cfm per foot of belt width but not less than 200 fpm through open area 3,500 Remarks Many codes specify mini mum down draft of 80 fpm See references for details and other operations Hood with 1-in slot ex tending 120 to 180 deg container Does not con fine spillage Confine spillage--also recom mended for container up setting 1017
Document image
refid# rekLxxjMnebzx9r0pvyYLv4yG1 page
orating solvent and is independent of the volume of the oven From the following table Lower explosive limit for n-heptane = 12 percent Vapor volume = 22 cu ft/gal Exhaust rate _ 22 X 100 required to dilute -- 12 vapors to the lower explosive limit = 1833 cu ft/hr = 30 6 cfm This rate is normally multiplied by a safety factor of about 5 to allow for imperfect mix ing Therefore 30 6 X 5 = 153 cfm exhaust rate For more precise calculations, see NFPA Standard No 86A, Ovens and Fur naces Explanation of Table Headings Column headings of the table (pages 12121231) are explamed as follows Listing of substances The "chemical hazards" table lists those physical properties associated with the fire and health hazards of common industrial chemicals (For tables of threshold limit val ues and maximal acceptable concentrations, see Chapter 38, "Industrial Toxicology ") Data in the table have been taken from the following principal references Standard 49, Hazardous Chemicals Data, and Standard 325M, Flammable Liquids, Cases, and Vola tile Solids, both published by the National Fire Protection Association, 470 Atlantic Ave , Boston, Mass 02210, and Handbook of Or ganic Industrial Solvents, published by the Amencan Mutual Insurance Alliance, 20 N Wacker Dr, Chicago, 111 60606 Be sure to check latest editions of these standards and booklets Other information is contained in Chapter 46, "Safety Engineering Tables," Table 46-0, "Explosion Characteristics of Various Dusts " Check the Cross Index for names of chemi cals and compounds that may be listed under another name (See pages 1208-1211 ) Column 1 Flash point is the lowest temperature at which the liquid gives off vapor within a test vessel in sufficient concentration to form an igmtable mixture with air near the surface of the liquid The flash point is used by OSHA and NFPA to define and classify the fire haz ard of liquids (see Chapter 42, "Flammable and Combustible Liquids") A standard closed container is used to de termine the closed-cup flash point of a liquid and a standard open-surface dish is used for the open-cup flash point determination, as specified by the standards of the Amencan Society for Testing and Matenals (ASTM) Unless otherwise specified, the flash point values in the table are dosed-cup determina tions Column 2 Flammable or explosive limits are those concentrations of a vapor or gas m air below or above which propagation of a flame does not occur on contact with a source of igni tion The lower limit is the minimum vapor concentration below which the vapor-air mix ture is too "lean" to bum or explode The upper limit is the maximum vapor concentra tion above which the vapor-air mixture is too "rich" to bum or explode Flammable or explosive limits are given in the Table in terms of percentage by vol ume of gas or vapor m air, and, unless other wise noted, at normal atmospheric pressures and temperatures Increasing the tempera ture or piessure lowers the lower limit and raises the upper limit Decreasing the tem perature or pressure has the opposite effect Column 3 Vapor volume is the number of cubic feet of solvent vapor formed by the evaporation of one gallon of a liquid at 75 F Column 4 Severtty and type of hazard Each haz ardous substance presents a distinct problem and must be treated individually m the light of its own characteristics Conclusions regard ing the hazards of a product cannot safely be drawn either from the properties of the ma tenals from which it is formed or by analo gies based upon chemical structure Mixtures of two or more chemicals may have properties that vary in kind or degree from those of the individual components Impunties may con- 1201
Document image
refid# pOaNzd7Kr8Zx4jMnoVZxgbga1 page
Foimic acid Fuel oil No 2 Fuel oil No 5 Fuel oil No 6 Furfural Furfurx 1 alcohol Gasoline Glycerine n-Heptane n-Hevane sec-Hexyl acetate Hexylene glycol Hydrazine Hydrochloric acid Hydrocyanic acid Hydrofluoric acid Hydrogen 156 - W-7,4 3,2 Cor.
Document image
refid# xdbwRJVyZmZe607b185azo8nQ1 page
43--Fire Protection crease the clearance up to 36 in over large, closely packed piles of combustible cases, bales, cartons, or similar stock 6 Conosion of sprinklers in such locations as bleachenes, dye houses, oi chemical operations Use sprinklers specially pro tected for use in such locations 7 Inadequate supplv of water because of faultv design oi poor maintenance Verify that water conditions have not changed since original plant installation It is im portant that the system be sturdily installed and anchored because explosions can jolt the piping and render the system ineffec tive Water spray systems Watei spray is effective on all types of flies wheie there is no hazardous chemical leacbon between the water and the matenal that is burning These systems are independent of, and supplemental to, other forms of piotection --not a replacement for automatic sprinklers Fixed watei sprav systems are similar to the standard deluge system except that the open spunklers are teplaced with spray-type nozzles The water supply to the system can be conti oiled automatically or manually They are geneially used to protect flammable liquid and gas tankage, piping and equipment, cool ing towers, and electrical equipment, such as transfoimers, oil switches, and motors (Fig 43-32) Because of its low electrical conduc tivity, water spiav applied thiough fixed piping systems on electncal equipment with voltages as high as 345,000 volts has pioved piactical When applied on some tvpes of electrical equipment, water spiav may cause shoit circuits bv foiming a continuous path of watei between energized parts In such cases, means should be piovided foi cutting off the electnc cunent befoie the watei spray is ap plied (See NFPA Standard No 15, Water Spray Fixed Systems ) The tvpe of watei spiay lequned depends upon the natuie of the hazatd and the puipose foi which the piotection is provided The basic pnnciple of water spraying is to give a complete surface wetting with a pre-selected water density, taking into consideiation nozzle tvpes, sizes, spacing, and watei supplv Watei sprav systems can be designed effec- 1368 Fig 43-32 --A water spray system for oil-filled electric power transformers A thick layer of crushed stone and subsurface drainage is provided around the base of the transformer installation to prevent burning oil from flowing beyond the area protected by the spray Courtesy National Fire Protection Association tivelv foi any one oi any combination of the following 1 Extinguishment of fiie 2 Control of fire wheie extinguishment is not desirable, such as gas leaks 3 Exposure piotection, that is, absorb the ladiant heat bv evaporation of the sprav 4 Pievention of fire Since the passages m a watei spiay nozzle aie small in comparison with those in the oidinaiv sprinkler, they can easily be clogged bv foreign mattei m water Therefoie, strameis aie ordinallly lequired m the supply lines of fixed-piping spiay systems The strainer basket should have holes small enough to piotect the smallest orifices of the nozzles used In cases where the nozzles have ex tremely small water passages, they may have their own internal stiainei in addition to the supply-line strainei
Document image
refid# aJwkbVooLz5Kz42gY7QZL2q7B1 page
II.
Document image
refid# ByvaxeyOxe3zGqXqBxq5mw8Mm1 page
45--Motorized Equipment In addition to these, the following aie lecommended for dump trucks A light or indicator to show when the body is in a raised position A Caution sign on the real of "packerloader" trucks Cab protector or canopy A built-in body prop Loading and unloading of trucks.