Refine
Estimated Years 1980-1989Clear
14,918 results foundRefine Search
UNITED STATES DISTRICT COURT EASTERN DISTRICT OF MISSOURI CAST .OJ VISION R T OAV IS, ET Al . , r> RECEi VEDSEP 3 01985 PLAINTiffs, CAUSE NO. 80-722CC4) i_ V. .r u.
Document imageDocument imageDocument imageDocument image
refid# yK7d4ZjmyoVB0x8MrOzdEaO2184 pages
TECHNICAL CHANGE ORDER f) CertairiTeedEI CerlainTeed Corporation Pipe and Plastics Group applicable to: A/C Standard Product Specificat ion Spec. #13 BVff 6f issue: May 1 , 1982 T.C.O.
Document imageDocument imageDocument imageDocument image
refid# kmOr780kJB7KKb8JJwxXRJw4q17 pages
PLAINTIFF'S EXHIBIT CHV-491 CHEVRON U.S.A.
Document imageDocument imageDocument imageDocument image
refid# 8XON5Jb6vk584zbgRLQ4B3o513 pages
CertainTeedH To Mail Code Mr.
Document image
refid# NGgmKdkqB88RB3MVLKOkzgvKy1 page
Specification IRM-MS-1381-J Chevron THERMAL INSULATION FOR HOT LINES, VESSELS, AND EQUIPMENT FOR HOT LINES, VESSELS, AND EQUIPMENT thermal insulation March 1989 (MS1381J.WP, 4/18/89) Page 1 of 10 CHEV BB OlfUCH Chevron Specification IRM-MS-1381-J THERMAL INSULATION FOR HOT LINES, VESSELS, AND EQUIPMENT CONTENTS 1.0 SCOPE 2.0 MATERIALS 2.1 Acceptable Materials 2.2 Insulation 2.3 Stainless Steel 2.4 Weatherjacketing 2.5 Weather Jacket Attachment Fixtures 2.6 Storage of Materials 1 3 3 3 3 4 4 4 3.0 GENERAL INSTALLATION REQUIREMENTS 3.1 Condition of Surfaces to Be Insulated 3.2 Insulating Cement and Bore Coatings 3.3 Valve Bodies, Flanges, and Manways 3.4 Double-Layer Insulation 3.5 Weatherjacketing 4.0 SPECIFIC REQUIREMENTS FOR PIPING 4.1 Applicable Drawings and Forms 4.2 Insulation Requirements 4.3 Weather Jacket Requirements 4.4 Insulation for Traced Lines 5.0 SPECIFIC REQUIREMENTS FOR VESSELS,COLUMNS,AND HEAT EXCHANGERS 5.1 Applicable Drawings and Forms 5.2 Insulation Requirements 5.3 Weather Jacket Requirements 6.0 SPECIFIC REQUIREMENTS FOR MISCELLANEOUSEQUIPMENT 6.1 Applicable Forms 6.2 Protection of Mechanical Equipment 6.3 Plastic Insulation 7.0 INSPECTION 8.0 FORMS AND DRAWINGS 4 4 5 5 5 5 6 7 7 8 9 9 9 9 10 12 12 12 12 12 12 March 1989 (MS1381J.WP, 4/18/89) Page 2 of 10 CHEV BB 010492 Chevron Specification IRM-MS-1381-3 THERMAL INSULATION FOR HOT LINES, VESSELS, AND EQUIPMENT 1.0 SCOPE This specification covers the requirements for insulating hot surfaces on vessels, heat exchangers, piping, and equipment using conventional types of insulation such as calcium silicate, mineral wool, fiberglass, or cellular glass.
Document imageDocument imageDocument imageDocument image
refid# EqeVx2wBzL39ZZXGbKVJ1DJgb10 pages
Special Article Medicolegal Aspects of Asbestos for Pathologists c * i r nnn i c The t-o orincieal Itgtl femeOie* avails a to victim* ot atStcoi-ra'alaO Citeaia art m; etaimt fcr eanatitt undar w:-.at*' :ansantat.on !
Document imageDocument imageDocument imageDocument image
refid# 10YX4r38o62RzwRjvLjwoJz5Z5 pages
OAF CORPORATION Interoffice _ Correspondenc To: Mr.
Document image
refid# g2GbLxg1Gxg8X6DEa5Ry5VRQ31 page
STERLING CHINA CO.
Document image
refid# x0ayZOb8dvkORo1GmONBzkJ01 page
(b) Tests, studies, surveys and/or research of any type concerning the hazards and/or potential exposure associated with any specific type and/or brand of asbestos-containing material/product, including but not limited to, materials/products that were manufactured, sold, distributed, installed, applied and/or otherwise used by defendant and/or any predecessor/related entity, other than those already identified in response to Standing Order No. 1 Interrogatories; (c) Tests, studies, surveys and/or research of any type concerning the relationship between exposure to asbestos and any disease, including pleural disease, asbestosis, lung cancer, mesothelioma and/or cancer of any kind; (d) Dust counts, industrial hygiene surveys, tests relating to TLVs, and/or like studies, tests and or surveys concerning the propensity of any material/product to release asbestos fibers (including but not limited to, materials/products that were manufactured, sold, distributed, installed, applied and/or otherwise used by defendant and/or any predecessor/related entity) and/or the quantity of fibers released; (e) Dust counts, industrial hygiene surveys, tests relating to TLVs, and/or like studies, tests and or surveys concerning the presence of asbestos fibers at any facility, location and/or area (including but not limited to, those owned, operated and/or controlled by defendant and/or any predecessor/related entity) and/or the quantity of fibers present; (f) Tests, studies, surveys and/or research of any type designed to reduce or eliminate inhalation of asbestos and/or asbestos fibers by persons working with and/or around asbestos and/or asbestoscontaining materials/products; and/or (g) Research of any type concerning asbestos.
Document image
refid# Rj5DkYnRrxpY5eVzrY8KvzZ8n1 page
Colt Industries Garlock Inc Mechanical Packing Division 1666 Division Street Palmyra.
Document image
refid# ypMb8ZBKLONQde70z30JyG6dD1 page
FILE COPY Hit TECHNICAL REPORT for Garlock, Inc.
Document imageDocument imageDocument imageDocument image
refid# 37kYMDLXOrngr3mgNy4mZa48D8 pages
J-M Manufacturing Co., Inc.
Document imageDocument image
refid# rB6vwv7K54rJyBr7x3wyOQQdq2 pages
J-M Manufacturing Co., Inc Internal Correspondence To ALL PLANT MANAGERS Date: From : g. e.
Document imageDocument imageDocument imageDocument image
refid# 2JL4wjzEqVpk915gvoBE0ev4L5 pages
m OPERATIONS MANAGEMENT AGREEMENT Da--: December 30. 1983. ?
Document imageDocument imageDocument image
refid# a87aJM0mGD5MM7OQxw6qNRJy3 pages
1 J-M Manufacturing Company, Inc.
Document imageDocument imageDocument imageDocument image
refid# Y9kjxwaG8d8Q5XjaRa4Z0X5OO6 pages