39.
refid# gbBxVmX7vMrpQmZNXOdREO6BL1 page
SCF-ALLF-02224 OFFICERS OF THE INDUSTRIAL CONFERENCE NATIONAL SAFETY COUNCIL 1962-63 I for InJuttry and CImairntan--ClyiiE F.
refid# kmZOzOgrrgex770eGeVKjGxvy3 pages
SAFETY ORGANIZATION AND SAFETY INSPECTION TABLE 2-A SUMMARY OF SAFETY ACTIVITIES REPORTED BY 54 AWARD WINNERS Management responsibility: Actively supports program 54 Has published safety policy.. 36 Publishes general safety rules 39 Publishes specific safety rules .. 38 Status of safetv organization Staff--all locations lane--all locations Staff at main office- line at branches 38 5 5 Employs full time safety director. . 54 Safety director reports to Chief personnel officer Chief labor or industrial relations officer Plant manager .
refid# e7maeGapRz0Q6pjdB9RgLE75e1 page
SAFETY ORGANIZATION AND SAFETY INSPECTION "Safety sampling" technique This technique is based on the random sampling application of probability theory which is used in production control As a result of applying the ``safety sampling" technique to accident prevention, manage ment is provided with a succinct statement of how safe a plant is operating, where trouble spots are (by areas and foremen), and the types and frequency of infractions As indicated by the title, "safety sam pling" requires that a statistical sample be determined The number of observations required to implement the "safety sampling" technique is based on a preliminary survey and the degree of accuracy desired In the preliminary survey, a member of the safety department should walk rapidly through the entire plant being studied and observe ell employees who are working It is impor tant in random sampling that only instan taneous impressions be recorded and that no attempt be made to correct an unsafe act during compiling time During this pre liminary tour, two types of impressions are recorded (1) count each worker who is performing his task safely and (2) count each worker who is performing his task unsafely It is important that each unsafe operation be recorded, therefore, one work er's operations may be recorded several tunes Each unsafe task is categorized by type of infraction, thus the analysis also indicates the types and locations of unsafe operations From these preliminary data, the percent age of unsafe operabons is determined by dividing the number of unsafe operabons by the total number of observabons (both safe and unsafe) The percentage of un safe operabons (P) is then used in the formula to calculate the number of observations (N) required to obtain a desired accuracy (Y) For example, assume a total of 200 ob servations of which 50 are unsafe observa tions, then P-- (50/200) (100) =25% The quanbty Y is assigned a value of accuracy considered satisfactory by the safety department For most cases Y = 10 per cent is sufficient Then by subsbtubon into the formula 4/1--0 25) N = (010)`(025) = 1200 observations.
refid# RjYNe70K3m0JR4n6eoJ5ejovX1 page
INDUSTRIAL BUILDINGS AND PLANT LAYOUT Fig. 14-3.
refid# YrmdDqMqKa5eNvXXQjNOgeM0k1 page
17CHAPTER MANUAL HANDLING AND STORAGE OF MATERIALS Manual handling- lifting team lifting and carrying handling specific shapes . . machines and other heavy objects____ -- ...-------------------------------------------------------------------------17-1 Accessories for manuol handling: hand tools . . . jacks .
refid# oDjgOO7LBbjkxOor5MEQ5oO531 page
ii'H
refid# 2R70a9joJLK390knrV3e8Vqbg1 page
MANUAL HANDLING AND STORAGE OF MATERIALS Aisles leading to spnnkler valves and fire extinguishing equipment should be kept clear.
refid# EqGqD5OQLvz9XLdV5pNRXBNE01 page
HOISTING APPARATUS AND CONVEYORS spondingly increase the strength of the blocks Calculation will show that in most instances using a safety factor of 10 for the rope will automatically keep the load on blocks corresponding to the rope size within safe working load limits Blocks should be plainly marked with their safe working loads as specified by their manufacturers, and the total weight on the tackle never should exceed this Breaking strengths of fiber ropes are shown m Chapter 21, "Ropes, Chains, and Slugs " Safe working loads for rope used m block and tackle assemblies are, conversely, 1/10 of the block's breaking strength, based on a safety factor of 10, as before For new rope, to find the required break ing strength, proceed as follows For each sheave 3 in in diameter or larger, add 10 per cent to the weight of the load to com pensate for friction loss Divide this figure by the number of ropes or parts running from the movable block, and multiply the resultant figure by a safety factor of 10 For example, a load to be lifted weighs 2,000 pounds and the tackle consists of two double blocks--four sheaves, four rope parts at the movable block Friction loss (10 per cent for each sheave) = 40 per cent, or 800 pounds, 2,000 + 800 = 2,800 pounds, which divided by 4 (the number of parts at the movable block) = 700 Applying the safety factor of 10 (10 x 700) gives 7,000 pounds, the required breaking strength of the rope New manila rope of %-inch diameter has a breaking strength of 7,700 pounds and there fore is the proper size for the load.
refid# 10ZVbzqLveXdYx4paGL1pEb3a1 page
ELEVATORS AND PLANT RAILWAYS steam (5 pa or less) or hot water pipes only for heating the hoistway and the machine room (or penthouse) are permitted The entire conduit system should he ef fectively grounded All electrical installa tions, including grounding, should conform to the Notional Electrical Code * Fits To protect persons working m ele vator pits, a minimum clearance of 2 ft is necessary between the lowest projection on the underade of the car platform (not in cluding guide shoes and aprons attached to the sill) and any obstruction in the pit (ex clusive of compensating devices, buffers, buffer supports, and similar devices) Meas urements should be made when the car is resting on fully compressed buffers Counterweight runways should be en closed from a point 1 ft above the pit floor to a point at least 7 ft above the pit floor and adjacent pit floors, except where compensating chains or cables are used The 1-ft space at the bottom is necessary to permit checking the clearance between the counterweight and the floor when the car is at the upper limit of travel Screen partitions at least 7 ft high be tween adjacent pits will protect men in one pit against cars and counterweights in ad jacent pits, and will protect employees from hazards when adjacent pits are at different levels An elevator pit should never be used as a thoroughfare or storage space It should be fully enclosed and entrances kept locked A dram should be provided for removal of water Pits should be kept dean and free of debris Rubbish never should be swept into pits Machine rooms should have safe and con venient access, as specified in the Elevator Code So that persons repairing or inspect ing elevator hoisting machinery have suffi cient room and are safe, there should be at least 7 ft of headroom between the ma chinery platform and the machine room roof Like pits, elevator machine rooms should never be used as thoroughfares The one exception would be if the elevator equip ment were in a separate locked enclosure Rooms should he well ventilated and lighted with not less than 10 foot-candles at floor level Doors should be kept locked to pre vent entry of unauthorized persons Machine rooms should be kept clean and should not be used for storage Small quanti ties of ordinary maintenance supplies should he placed in a wall cabinet A portable car bon dioxide or diy-powder fire extinguish er should be kept within reach of someone standing at the door Overhead protection If the elevator ma chine is located in the penthouse, a sub stantial grating or floor of fire-resistant construction should be provided under the machine For detailed information concern ing construction, the Elevator Code should be consulted On all overhead machine installations there should be a cradle below the secondary sheaves if they extend below the floor or grating No elevator machinery except the idler or deflecting sheaves should be hung under neath the supporting beams at the top of the hoistway When the governor or other devices (other than terminal stopping switches) must be installed below the ma chine floor, they should he set on a sub stantial secondary floor For winding-drum machines, a substan tial beam or bar should be placed at the top of the counterweight guiderails and beneath the counterweight sheaves to prevent the counterweights from being drawn into the sheaves landings and doors The Elevator Code specifies that hoist way landing openings of all power-dnven elevators must be provided with hoistway doors that guard the full height and width of the openings Hoistway doors for passenger elevators Records show that most elevator accidents occur at the hoistway door and are divided almost equally between "caught and crushed" and "falls down hoistway " Interlocks of approved types properly installed and main tained will eliminate practically all such ac cidents Many senous accidents and fatalities `National Fire Protection Association, 60 Batterymarch St., Boston.
refid# 5ka1802g2G9q1pg8qm6dbxdYD1 page
comers of buildings or other places where workers may walk directly onto tracks in front of moving cars These locations may be safeguarded with fixed railings that force pedestrians to detour a short distance before stepping onto the track If a barrier railing is impractical, hinged bars or gates swinging horizontally through an angle of not more than 90 degrees are effective Still another means is a convex mirror located at the intersection of the passage way and the track at a 45-degree angle, in which approaching railway equipment can be seen before the intersection is reached Various methods are used to warn pedes trians at railway crossings inside plants Automatic wigwags, blinking lights, and gongs are more effective than signs Heavi ly traveled roadways can be safeguarded ef fectively by gates equipped with red lights and by watchmen, who should be provided with a whistle and a shielded red lantern The visibility of gates is increased by painting them with alternate yellow and black stripes at an angle of about 45 degrees Another means of protection u the warn ing system shown m Fig 19-14 Track All track, fittings, and structure should be installed m accordance with AREA specifications (see footnote on page 19-24) for the service required --------- fir---------------- ..
refid# ppgMa79Or263EGnby3v8dwNEB1 page
COLD FORMING OF METALS Fig. 23*25.
refid# vBxLMkMBb73YRg3LZyDDgGkN91 page
EXHAUST SYSTEMS, GENERAL 6 COMFORT VENTILATION IONIZER COLLECTOR PLATES Fig. 28*10.
refid# EqebGK4Xxq6ezm45wb7ovz0dn1 page
34CHAPTER FIRE EXTINGUISHMENT AND CONTROL Water system*. water supply and storage . automatic sprinklers water spray systems hydrants, hoses, and nozzles-------------------------- 34-1 Special systems and agents: foam systems wet water carbon dioxide extinguishing systems dry-chemical sys tems steam systems inerting systems--------------------------------------------- 34-11 Portable fire extinguishers principles of use water-solution extinguishers dry-chemical, carbon dioxide, and liquified- gas extinguishers dry-powder extinguishers federal rules on fire extinguishers miscellaneous equipment training of employees maintenance and inspection34-16 Equipment used to extinguish and control fires is of two types fixed and portable Fixed systems include water equipment automatic sprinklers, hydrants, standpipe hoses, and special pipe systems for dry chemical, carbon dioxide, and foam Special pipe systems are applicable to areas of high fire potential where water may not be effec tive, such as tanks for storage of flammable liquids and on electrical equipment Fixed systems, however, must be supple mented by portable fire extinguishers These often can eliminate the action of sprinkler systems because they can prevent* a small fire from spreading as well as provide rapid extinguishment in the early stages of a fire (See Fig 34-4 ) Water Systems Water supply and storage Sprinkler systems need a reliable water supply of ample capacity and pressure for efficient fire extinguishment (Fig 34-2) For example, to supply all sprinklers likely to open in addition to hose streams, a vol ume as high as 500 to 1,500 gpm may be needed The precise need depends on the occupancy classification Pressure should be high enough to maintain a residual pres sure of 15 psi in top-story sprinklers Water may be supplied from the follow ing sources 1 Public water works underground supply mams 2 Automatically or manually controlled pumps drawing water from lakes, ponds, nvers, surface storage tanks, under ground reservoirs, or similar adequate sources 3 Pressure tanks contaming two-thirds water and one-third compressed air for This chapter was revised by Marshall Petersen based on reviews by selected mem bers of the National Safety Council 34-1
refid# dD5OQoNw0pp6MY2gJVX4qNXv51 page
K 007578 mis WMWiWiitaga iBHaBBfnamaitaiaaiiiBitiaMa :fcaaa Biiiiigti MBMiMMigB liiii aaiaiBlaailai ' iHfr-a-ar fc mw-m / *; / f K 007588 aa: Ji,.at:i;3Lm,.Ja;i.it;.ayai.u,.