ELEVATORS AND PLANT RAILWAYS steam (5 pa or less) or hot water pipes only for heating the hoistway and the machine room (or penthouse) are permitted The entire conduit system should he ef fectively grounded All electrical installa tions, including grounding, should conform to the Notional Electrical Code * Fits To protect persons working m ele vator pits, a minimum clearance of 2 ft is necessary between the lowest projection on the underade of the car platform (not in cluding guide shoes and aprons attached to the sill) and any obstruction in the pit (ex clusive of compensating devices, buffers, buffer supports, and similar devices) Meas urements should be made when the car is resting on fully compressed buffers Counterweight runways should be en closed from a point 1 ft above the pit floor to a point at least 7 ft above the pit floor and adjacent pit floors, except where compensating chains or cables are used The 1-ft space at the bottom is necessary to permit checking the clearance between the counterweight and the floor when the car is at the upper limit of travel Screen partitions at least 7 ft high be tween adjacent pits will protect men in one pit against cars and counterweights in ad jacent pits, and will protect employees from hazards when adjacent pits are at different levels An elevator pit should never be used as a thoroughfare or storage space It should be fully enclosed and entrances kept locked A dram should be provided for removal of water Pits should be kept dean and free of debris Rubbish never should be swept into pits Machine rooms should have safe and con venient access, as specified in the Elevator Code So that persons repairing or inspect ing elevator hoisting machinery have suffi cient room and are safe, there should be at least 7 ft of headroom between the ma chinery platform and the machine room roof Like pits, elevator machine rooms should never be used as thoroughfares The one exception would be if the elevator equip ment were in a separate locked enclosure Rooms should he well ventilated and lighted with not less than 10 foot-candles at floor level Doors should be kept locked to pre vent entry of unauthorized persons Machine rooms should be kept clean and should not be used for storage Small quanti ties of ordinary maintenance supplies should he placed in a wall cabinet A portable car bon dioxide or diy-powder fire extinguish er should be kept within reach of someone standing at the door Overhead protection If the elevator ma chine is located in the penthouse, a sub stantial grating or floor of fire-resistant construction should be provided under the machine For detailed information concern ing construction, the Elevator Code should be consulted On all overhead machine installations there should be a cradle below the secondary sheaves if they extend below the floor or grating No elevator machinery except the idler or deflecting sheaves should be hung under neath the supporting beams at the top of the hoistway When the governor or other devices (other than terminal stopping switches) must be installed below the ma chine floor, they should he set on a sub stantial secondary floor For winding-drum machines, a substan tial beam or bar should be placed at the top of the counterweight guiderails and beneath the counterweight sheaves to prevent the counterweights from being drawn into the sheaves landings and doors The Elevator Code specifies that hoist way landing openings of all power-dnven elevators must be provided with hoistway doors that guard the full height and width of the openings Hoistway doors for passenger elevators Records show that most elevator accidents occur at the hoistway door and are divided almost equally between "caught and crushed" and "falls down hoistway " Interlocks of approved types properly installed and main tained will eliminate practically all such ac cidents Many senous accidents and fatalities `National Fire Protection Association, 60 Batterymarch St., Boston. National Elec trical Code Standard No. 70 (ASA Cl). 29-6