58 Chapter 2 1945 Guide change of about 3 deg ET is required to change a person's sensation from ideally comfortable to cool or warm.
Document image
refid# 3NoO5yD7G6j5YqRD8V5vkyoLJ1 page
136 Chapter 6 1945 Guide ---Walls-Adjoining Garage:. _ Plaster onl in. insulation board, studding, metal lath and plaster (0.18).
Document image
refid# a4y2kjVnGmgknXD0kmoyxgrNb1 page
218______________________________ Chapter 11__________ 1945 Guide \' If the degree-days occurring each day are totaled for a reasonably long - period, the fuel consumption during that period.as compared with another period will be in direct proportion to the number of degree-days in the ` two periods.
Document image
refid# yp4Q8Lo3X0RRBGRNZKXGXNn031 page
488 Chapter 25 1945 Guide off the-accumulation"with-steam, compressed-air-and waterTor hot water -The most satisfactory solution, however, is to keep the filters serviced, and thus make the cleaning of the coils unnecessary.
Document image
refid# wDeQGVvj5xEnvx6ezjKrDbNz41 page
616 Chapter 33 1945 Guide APPLICATION OF CONTROLLING DEVICES TO A TYPICAL SYSTEM 7 Fig. 1 shows the location of controlling devices for a year 'round air conditioning system such as shown in Chapter 20, Fig. 3.
Document image
refid# 3ewXGxVGp4Mqanyow42VaJ4x1 page
308 CHAPTER 16 1946 Cuide FIRING METHODS FOB ANTHRACITE An anthracite fire should never be poked or disturbed, as this serves to bring ash to the surface of the fuel bed where it may melt into clinker.
Document image
refid# zoDgjQmZvEmgzazVRn192dR8n1 page
320 CHAPTER 17 1946 Guide Automatic Fuel Burning Equipment 321 Fig. 6.
Document image
refid# kDMYMk4JjR0anXeYQwxme6aB1 page
398 CHAPTER 21 1946 Guide - /--"> --i fIt/Mfefacl./.sj/hield ex tending id beyond casing. ......... ' oJrc,ix:fcs ,s --1 sr space- open'- Insulated with airspace or cov ered with magne sia. asbestos. or sand.
Document image
refid# DrKNpdrpOwjeo5jk62RevMLQ1 page
146 CHAPTER 7_______ i <- Then substituting values for Aa, A, and G, N may be found as follows: 10.7 X 151V _ 0.243 X 1740 = 2 5 fr0m Which> N = 6 58 1948 Guide (2) This establishes the maximum whole number of coil rows that can be used as 6 and it is now possible toi determine the actual location of the exit air conditions from Equation 7 by solving for the actual value of ti -- 1dpi for a 6 row coil. 10.7 X 15 X 6 , 102 - 80 0.243 X 1740 081 *i " fdps = 2.275 This establishes values of 9.78 for 7-----7^ = R and 2.25 for h -- fdm. h -- *dpi (3) Next, the exit air condition at 57.3 F dry-bulb and 56 F wet-bulb as shown at B, is found by locating a point on the load ratio line at q horizontal distance of 2.25 dry-bulb degrees from the saturation curve
Document image
refid# 2RZ1ZgrXK6grLmwpOO8G2bx4N1 page
656 CHAPTER 37 1948 Guide.
Document image
refid# O33Bx4r9gJogomxgVvnaRmRwM1 page
822CHAPTER 45 -' 1948 Guide .
Document image
refid# m3E32goaKOGnJJ8a1emnGL4B1 page
868 CHAPTER 50 1948.
Document image
refid# 37MMOZ61orQy4MzK585v6jv31 page
932 1948 Guide HEATERS, Feed-Water - \ Crane Co;, 1148*1149' ' Ilg Electric.
Document image
refid# Znxq2r85VyE9XeZX4nNLQ5yz71 page
334 CHAPTER 16 1949' Guide is determined in a caloiimeter the water vapor is condensed and the latent heat of vaporization is included in the heating value of the fuel.
Document image
refid# mVX4NgwR21BkkLQk0kBpJJ4g1 page
450 CHAPTER 22 Fia. 3.
Document image
refid# 6BKvRnYyEVrYLw30RexN4mZLd1 page