Document a4y2kjVnGmgknXD0kmoyxgrNb
136
Chapter 6
1945 Guide
---Walls-Adjoining Garage:. _ Plaster onl in. insulation board, studding, metal lath and
plaster (0.18). Basement Walls (Recreation Room): 10 in. concrete (0.10).
.
Roof: Asphalt shingles on wood sheathing on rafters (0.53).
Ceiling (Second floor): 1 in. insulation board and plaster; K in- insulation board on
top of ceiling joists (0.15).
Windows: Same as Example 5.
' ;1
Floor (Bedroom D): Maple finish flooring on yellow pine sub-flooring; Yi in. insulation board and plaster ceiling below (0.18).
Solution: The procedure for calculating the heat losses is similar to that for Example
5. A summary of the results is given in Table 6.
.
Table 6. Summary of Heat Losses of Insulated Residence Heat losses given in Btu per hour
Room ob Spacx
Walls
Celling and Root
Floor
Glass and Door Infiltration
Totals
Bedroom B
Bedroom D Bathroom 1 Bathroom 2 Living Room Dining Room Kitchen
Recreation
Totals
Percentages
2670 1750 . 1280 1320
340 820 .3580 1860 1400 1460 440 ' --400s 840
17,360 .
31.9
2370 1570 1170 1170
540 340
850
8,010 14.7
___ _
690 '__ 220
-1190b 570 290 0.5
1440 1440
970 720 500 320 1800 3880 950 1100 640 3410 720
17,890
32.8
1010 1010
500 500 500 420 1120 870 760 530 560 2700 490
10,970
20.1
"Wall heat loss of 1050 Btu minus wall heat gains of 590. 320 and 540 Btu bHeat gains; 690. 220 and 280 Btu.
7,490 5,770 3,920 4,400 1,880 2,120 6,500 6,610 3,110 3,090 2,490 4,520 / 2,620
54,520
100.0
CHAPTER 7
(Jooiinc^ <jC.oa.xi
Design Outside Temperatures, Components of Heat Gain, Normal Heat Transmission, Solar Heat Transmission, Solar Radiation Through Glass, Heat Introduced by Outside Air,
Heat Emission of Appliances, Moisture Through Walls
LOAD calculations for summer air conditioning are more complicated, than heating load calculations because there are more factors to be considered. Due to the variable nature of some of the contributing load components and the fact that they do not necessarily impose their maximum effect simultaneously, considerable care must be used in determining their phase relationship so that equipment of proper capacity may be selected to maintain specified indoor conditions. ,.
The conditions to be maintained in an enclosure are variable and depend upon several factors, especially the outside design conditions, duration of occupancy and relationship between air motion, dry-bulb and wet-bulb tetaperatures. Information concerning the proper indoor effective temperature to be maintained is given in Chapter 2, for different geographical locations and for various age groups of individuals.
Summer dry-bulb and wet-bulb temperatures of various cities are given in Table 1. The temperatures are not the maximums but the design temperatures which should be used in air conditioning calcu lations. The maximum outside wet-bulb temperatures as given in Weather Bureau reports usually occur only from 1 to 4 per cent of the time, and they are therefore of such short duration that it is not practical to design a cooling system for them. The temperatures shown in Table 1 are based on available design conditions known to be successfully applied.
COMPONENTS OF HEAT GAIN
A cooling load determination is composed of five components which are classified in the following manner;
1. Normal heat transfer through windows, walls, partitions, doors, floors, ceilings, etc. 2. Transfer of solar radiation through windows, walls, doors, skylights, and roof. 3. Heat emission of-occupants within enclosures. 4. Heat introduced by infiltration of outside air and controlled ventilation. 5. Heat emission of mechanical, chemical, gas, steam, hot water and electrical appliances located within enclosures.
The components of heat gain, classified by source, are further classified as sensible and latent heat gain.
The first two components fall into the classification of sensible heat gain, that is, they tend to raise die temperature of the air within the structure. The last three components not only produce sensible heat gain but they may also tend to increase the moisture content of the air within the structure.
Normal Heat Transmission
.By normal heat transmission, as distinguished from solar heat trans mission, is meant the transmission of heat through windows, walls, partitions, etc. from without to interior of enclosure by virtue of difference
t