TABLE 2: Inspection Information Summary Inspection Team Lead Inspector: Jordan Noles, Environmental Protection Agency (EPA) Inspector: Steven Ramirez, EPA Inspector: Justin Stark, EPA Inspector-in-Training: Callie Sotolongo, EPA Inspector: Brook McKowen, Eastern Research Group (ERG) Inspector: Amy Federoff, ERG Inspector: Liam Prendergast, ERG Date of Facility Visit: June 11-13, 2024 Page 2 of 11 Valero Memphis Refinery, Memphis, TN CAA 112 (r), Risk Management Program, Inspection Report Quantity (lb) 25,000 870,000 160,000 35,000 990,000 980,000 46,000 1,200,000 22,000,000 1,700,000 200,000 44,000 120,000 12,000 4,800 38,000 Facility Identification Name: Valero Memphis Refinery Street Address: 2385 Riverport Road City: Memphis County: Shelby EPA Facility ID No: 100000158107 Dun & Bradstreet (D&B) No: 199623414 Latitude: 35.085843 Longitude: -090.083385 State: Tennessee Name, address and phone of corporate parent company: Owner/Operator: Valero Energy Corporation Mailing Address: 2385 Riverport Road City: Memphis State: Tennessee Zip: 38109 Zip: 38109 Name, title, and email of person responsible for 40 C.F.R.
refid# pKMX0XLN20z0JjpE4JLvKXr711 pages
NPDES Inspection Report - Water Treatment Plant National Database Information Inspection Date: June 29, 2021 Inspection Type: CEI - Minor Entry / Exit Time: 8:30 am / 2:00 pm NPDES ID Number: WYDW0001I NAICS Code: 221310 Inspection ID: 202106_WYDW0001I Lead inspector and affiliation: Jessica Duggan / U.S.
refid# OJav92V7yz8w6L85RyN7bjNRQ13 pages
Comment on Proposed Restriction of PFAS May 30, 2023 Japan Fluoropolymers Industry Association (JFIA) We, Japan Fluoropolymers Industry Association (JFIA), think that fluoropolymers should be distinguished from the proposed restriction of PFAS (Per- and polyfluoroalkyl substances), which collectively regulates more than 10,000 of organofluorine compounds (PFAS) on the grouping basis.
refid# daVq30oZ8yxv5BrD16DwJjBz612 pages
The severe sequel of acne scarring can lead to long-term psychological injury.
refid# Ne189eQbBYEYL8k6Ke547DxLR14 pages
At the conclusion of each HAZOP, the Facilitator and RMP/PSM Engineer lead an action close-out meeting where individuals on the HAZOP team are assigned actions and the results of the HAZOP study are reviewed with the Operations Superintendent and the RMP/PSM Manager.
refid# Z8vN8e1vVXeGaKnnzw7VBprEV13 pages
Comment on Proposed Restriction of PFAS May 25, 2023 Japan Fluoropolymers Industry Association (JFIA) We, Japan Fluoropolymers Industry Association (JFIA), think that fluoropolymers should be distinguished from the proposed restriction of PFAS (Per- and polyfluoroalkyl substances), which collectively regulates more than 10,000 of organofluorine compounds (PFAS) on the grouping basis.
refid# pXK3bGaYr6V2GznZOp45M51712 pages
The road leading up to the tank had a fallen tree across it, making it so that vehicles could not pass (refer to Appendix 2, Photograph 18).
refid# LJXkdnNEMwYOvpgnoOk2OyXVq48 pages
., Oregon Potato Company Physical Address: 302 North Venture Road, Pasco, WA 99301 Phone Number: (509) 545-4545 Latitude/Longitude: 46.235270/-119.046150 RMP Facility ID# 1000 0020 4673 FRS ID#: 110036126563 EJ Concerns: Yes (84%) CONTACT INFORMATION (RMP Implementation): Name: Steve Harris, Plant Manager Phone Number: (509) 303-8244 E-mail: steve.harris@pascoprocessing.com EMERGENCY CONTACT INFORMATION: Name: Yuvani Noriz, Refrigeration Manager Phone (24-hr): (509) 303-8244 E-mail: yuvani.noriz@pascoprocessing.com Website: https://oregonpotato.com/ TRIP DETAILS: Inspection Date: Inspection Time: Inspectors: June 29, 2023 09:00 through 12:15 Terry Garcia, US EPA Region 10 SEE Grantee, Lead RMP Inspector Peter Phillips, US EPA Region 10 SEE Grantee, RMP Inspector Edward Johannes, US EPA Region 10 SEE Grantee, EPCRA Inspector Mhara Coffman, US EPA Region 10, RMP Inspector DATE AND PROGRAM LEVELS OF SUBMITTED RMP: Initial Submission Date: November 25, 2008 Date of Latest Update: June 10, 2019 Page 1 of 7 Process (Program 1, 2, 3) as reported in RMP: Process ID Description Process Chemical ID Frozen Fruit, 1000100207 Juice, and Vegetable 1000125514 Manufacturing NAICS Code 311411 Program Level 3 Chemical Name CAS Number Ammonia, Anhydrous (7664-41-7) Quantity (lbs) 19,000 PURPOSE: The purpose of this inspection was to determine whether this facility is in compliance with Section 112(r) of the Clean Air Act and Title 40 Code of Federal Regulations (CFR) Part 68, Chemical Accident Prevention Provisions.
refid# qdLREn62Gv2pZ0d7GxGnNqGwM8 pages
PROJECT TEAM MEMBERS Organization EPA Region 7, ECAD, Air Branch MoDNR, Air Pollution Control Project Role Lead inspector Field team member FACILITY CONTACT INFORMATION Table 3 lists the primary facility contact.
refid# Rp3awyxMBXD6ky93mBa4Kd3M715 pages
EQT is "a leading independent natural gas producer" with operations in Pennsylvania, West Virginia, and Ohio.
refid# om02xBeRewkKzg4Gjk3kNb9KR13 pages
Comment on Proposed Restriction of PFAS May 25, 2023 Japan Fluoropolymers Industry Association (JFIA) We, Japan Fluoropolymers Industry Association (JFIA), think that fluoropolymers should be distinguished from the proposed restriction of PFAS (Per- and polyfluoroalkyl substances), which collectively regulates more than 10,000 of organofluorine compounds (PFAS) on the grouping basis.
refid# o904Mq03MXYbZamRepLLEmZM812 pages
(AOC 5.c.ii) b) The Company did not document that all equipment at the Facility complied with recognized and generally accepted good engineering practices (" RAGAGEP "), and for existing equipment designed and constructed in accordance with codes, standards or practices that are no longer in use, the Company did not determine and document that equipment was designed, maintained, inspected, tested and was operating in a safe manner, in the following instances, in violation of 40 C.F.R. 68.65 (d) (2) and (d) (3) (AOCS 6 and 7): i) Results from the Ammonia Refrigeration Room (" AMR ") ventilation system tests from 2018-2021 showed that the ventilation systems at the Facility were not operating in accordance with RAGAGEP (AOC 6.a); 2 Delta Packing Company Show Cause Letter ii) A compressor lacked the feature to shut down when high - discharge - temperature was detected, according to compressor inspections in 2020 (AOC 6.c); iii) In the North Refrigeration System AMR 1, the door leading to the outside and the adjacent roll - up door were not tight - fitting at the bottom, and in the Southwest Refrigeration System AMR, the door leading outside and the roll - up door were not tightly sealed at the bottom (AOC 7.a); iv) The Company's relief analysis for the relief valve discharge piping for the liquid transfer vessel in the North Refrigeration System AMR 1 was insufficient to ensure that excessive back pressure would not develop (AOC 7.b); v) There was a fan in front of the opening of ARM 1 that could have blown ammonia laden exhaust through a square opening in the wall between the North Refrigeration System AMR 1 and the loading dock area potentially exposing personnel (AOC 7.c); vi) In the North Refrigeration System AMR 1, there were unsealed wall penetrations that could have allowed leakage of ammonia vapor to adjoining spaces and / or affect the fire rating of the AMR.5 (AOC 7.d); vii) There were no confined space warning signs on the cold room bunkers of the North Refrigeration.
refid# jmQpb6vRRQ8Km633z95BXpvM97 pages
Comment on Proposed Restriction of PFAS May 30, 2023 Japan Fluoropolymers Industry Association (JFIA) We, Japan Fluoropolymers Industry Association (JFIA), think that fluoropolymers should be distinguished from the proposed restriction of PFAS (Per- and polyfluoroalkyl substances), which collectively regulates more than 10,000 of organofluorine compounds (PFAS) on the grouping basis.
refid# ZJmBJ3DeD84KrjK7rGKDVdygJ12 pages
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY, REGION 2 CARIBBEAN ENVIRONMENTAL PROTECTION DIVISION MULTIMEDIA PERMITS AND COMPLIANCE BRANCH NPDES STORMWATER RECONNAISSANCE INSPECTION Industrial Activities Owner/Operator VIRGIN ISLANDS WASTE MANAGEMENT AUTHORITY 6196 Estate Glynn, Frederiksted, St.
refid# ExJ4vRxY8QQgNaOo9xyJMZXox19 pages
Comment on Proposed Restriction of PFAS May 25, 2023 Japan Fluoropolymers Industry Association (JFIA) We, Japan Fluoropolymers Industry Association (JFIA), think that fluoropolymers should be distinguished from the proposed restriction of PFAS (Per- and polyfluoroalkyl substances), which collectively regulates more than 10,000 of organofluorine compounds (PFAS) on the grouping basis.
refid# Mk57yJkZRoOaNJBod7eD3Owx12 pages