Refine
Estimated Years 1940-1949Clear
11,527 results foundRefine Search
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 in this method of design is to select the main duct velocity to be con sistent with good practice from a standpoint of noise for a particular type of building.
Document image
refid# Np4dbEmqYo9KJ2px3EaRoGYy1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 FIEDLER, Harry W.
Document image
refid# 3n6kGG9X7myDnekOvaxLkdV01 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 1902 President -...____ __A.
Document image
refid# QjkbZ6ZBD8DKNexkrgL845Ko1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1943 ditions in Fig. 6 and determined prior to 1932, has more recently been, checked; first, by occasional observations, and second, by consistent, laboratory study81, indicating that a higher optimum of 67 deg ET was preferred by a majority of the eight male college students whose opinions were ascertained.
Document image
refid# 6wpEyJ7zwjYDxkK0wq1YK6L1g1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1943 a small percentage of time.
Document image
refid# 2z6m805394No7a6gzOYM210N1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 times, also, brine from an industrial system already installed is the only convenient source of refrigeration.
Document image
refid# b56BEa38nnqnEej6gzgMrOpN11 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 The average jet angle (included angle in both planes, see Fig. 1) for an air stream as it emerges from a rectangular outlet of any shape without spreading vanes is about 19 deg, plus or minus 5 deg, .depending on the type of approach, type of outlet and velocity.
Document image
refid# O1eK5ZxwNX6L0Ka7G60342D6K1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1943 it is not practical to install a hood 2 ft high it is recommended that the face velocity be increased from 100 to 150 fpm, depending on peak load con ditions in the kitchen.
Document image
refid# a1xwQ7DpYvoRkQao36n3DxzZN1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 ROLL OF MEMBERSHIP KIMBALL, Dwight D.
Document image
refid# KRzOZ70Qv4gB5rERyeJDRpGmN1 page
HEATING VENTILATINC AIR CONDITIONING CUIDE 1943 U UHL, Edwin J.
Document image
refid# a1qZqGRnwZMqMYV1VpDk1d3BB1 page
; HEATING VENTILATING AIR CONDITIONING CUIDE 1944 For example, corresponding to 40 per cent saturation at 100 F, the relative humidity is 0.40 + 0.0667 X 0.40 X 0.60 = 0.416 or 41.6 per cent (15b).
Document image
refid# dYY8XK41GkKq4d4BaoLQwzM5R1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1944 be used beyond the coil to catch any water which may be blown into the air stream.
Document image
refid# JrMb7x15dZ9Bom1YXwdqGGKkB1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1944 which have to be met in the field, it is natural that many kinds of air cleaning devices are used which cannot be shown satisfactorily in a simple outline.
Document image
refid# 1ywrz3Lg0V4X8avw1QKNj6qzK1 page
HEATINC VENTILATINC AIR CONDITIONING CUIDE 1944 Compound Wound motors are required for application to reciprocating compressors, stokers, reciprocating pumps when started under loaded conditions, and also when applied to similar equipment where high starting torque is required.
Document image
refid# MkBDk51NX1R6RJapwp44yeny1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1944 the machine; and where a heavy vapor, or dust-laden air at ordinary temperature is to be removed, horizontal or floor connections are some times preferable.
Document image