HEATINC VENTILATING AIR CONDITIONING GUIDE 1941 7.
Document image
refid# YrNaOK8yGzGXQ17KvGQbp4evD1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1941 become important at dew-points below 50 F and have an extreme effect upon load and equipment selection at dew-points below 35 F.
Document image
refid# 06G4bagp22EVNk4JokL0JYmQJ1 page
HEATINC VENTILATING AIR,CONDITIONING GUIDE 1941 SMOKE STACKS Gases discharged from smoke stacks may contain relatively large particles of cinders and carbon as well as the fine smoke which remains in relatively permanent suspension.
Document image
refid# 2B9bkR297KmE7Op60LBG7V271 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1941 soldered to the core or by both pressure and soldering.
Document image
refid# Z8odovMNeLYxkZ9xqrMnXBqKZ1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1942 The left hand member of Equation 13 represents the total amount of available draft created by the pressure transformer, that is, the natural draft chimney, Venturi chimney, or fan, and is equal to the theoretical intensity less the internal losses incidental to operation.
Document image
refid# zbkr25GgNwMRXM4dkpkogLqw71 page
HEATINC VENTILATING AIR CONDITIONING CUIDE 1942 water in the direct return system among the several risers, it is necessary to introduce resistances to balance the circuit.
Document image
refid# VxmOYy4j8pKb9VLZZ2mp9vqw1 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1942 high operating costs, etc.
Document image
refid# rdrenm3GVy6kBeZQ4gEKK46E1 page
|j i. ii 5; HEATING VENTILATINC AIR CONDITIONING CUIDE 1942 be remembered that encroachment on spaces that are otherwise usable can be charged against the system as an operating cost.
Document image
refid# yb48dDwLGJRqGaYLZ5YevGGgE1 page
HEATINC VENTILATINC AIR CONDITIONING GUIDE 1942 order to prevent flooding of the lower dehumidifiers.
Document image
refid# Ne1eJGM9DV445kBnQxJ8XKneV1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1942 Capacity Tons 0 to 5 5 to 25 25 to 50 50 to 400 400 and Over Table 10.
Document image
refid# ddBmZ6Okk7RbERLR5Mj8Ykz61 page
HEATINC VENTILATING AIR CONDITIONING CUIDE 1942 the windward side near the bottom, white outlet openings are located on the leeward side near the top.
Document image
refid# 2JVBxbYa8NQk2v3Bx9KBGJerN1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 Table 1.
Document image
refid# Yjjkq2My5brR9qv95G4xgrxB01 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 Table 5.
Document image
refid# jyao47EYoGw429g1Y9R4wZZwZ1 page
HEATING VENTILATINC AIR CONDITIONING GUIDE 1943 Absorbents Any absorbent substance may be used as an air drying agent if it has a vapor pressure lower than the vapor pressure in the air-vapor mixture from which the moisture is to be removed.
Document image
refid# rBo9OQjV1jQRqvroY7j1GVp5V1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 cooling medium required is also less than for any other system with- the exception of the centrifugal compressor, which uses the same amount.
Document image
refid# wn7OaLo6EBkJZOykRV27Zo661 page