HEATING VENTILATING AIR CONDITIONING GUIDE 1942 ment of the vane is resisted by a hair spring and a damping magnet.
Document image
refid# wY82YZ4DGmXKmEDRd5qN0OzB1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 BREECHINGS AND CHIMNEYS Bethlehem Steel Co., 983 Farrar & Trefts. 1048 International Boiler Works Co., 1049 Kaustine Company, Inc., 888 Hendrick Mfg.
Document image
refid# LpD4BR12DRrqMdL6KpzX7LJp31 page
HEATINC VENTILATING .
Document image
refid# 93yRe8Bj1KoYDVaKxOwgXnGj51 page
vV-TA;- HEATING VENTILATING AIR CONDITIONING: GUIDE 1943 REFERENCES A.S.H.V.E.
Document image
refid# X7MB1yKK9a2qXDV0X0QYKNN3G1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 25 per cent for steam systems and 35 per cent for hot water systems is preferable to ignoring entirely the load due to heat loss from the supply and return lines, but better practice, especially when there is much bare pipe, is to compute the emission from both bare and covered pipe surface in accordance with data in Chapter 43.
Document image
refid# QozjjQk13E4OkbbgLqnQxOwk1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1943 one bank spraying with the air stream and one against it.
Document image
refid# Kz4yn3XBRYGJVY4brmLb7exK1 page
HEATING VENTILATINC AIR CONDITIONING GUIDE 1944 effective temperature for sedentary persons, as determined at the A.S.H.V.E.
Document image
refid# OoreqmL295jDGjMXoy4RRwjX1 page
HEATINC VENTILATINC AIR CONDITIONING CUIDE 1944 for several different combinations of temperature and wind velocity which records show to have occurred and to select the worst combination; but designers generally do not feel that such a degree of refinement is justified.
Document image
refid# emgnGjnB6bQVZkZLq4Y1g9B4m1 page
HEATINC VENTILATINC AIR CONDITIONING GUIDE 1944 Long Island-- Pizer, M.` M.
Document image
refid# xR8XLk3dbMY1V1Bzd4QYydEG1 page
so Chapter 1 1945 Guide Example 18.
Document image
refid# gD6p3bp31GOGObKNw30RpB6nN1 page
228 Chapter 12 1945 Guide __ .heat.exchangers of-thecoil-or-tube-types which-transniit-the-heat from the > . steam to the water.
Document image
refid# g2rm0waVNYdqwaaNggBBvbnre1 page
432 Chapter 23 1945 Guide the main'brine reservoir for. re-pumping.
Document image
refid# rxz0dz2ayOVj1zXvGNKvBzk71 page
706 Chapter 40___________ 1945 Guide AIR CLEANING EQUIPMENT Primary dust separators depend for their air cleaning action on centri fuging out the dust particles or on imparting to the transporting air' stream a quick change in direction, accompanied by a sudden reduction in velocity.
Document image
refid# 03VpDJ38jgRMMNa5gXbR08wM1 page
20 . .
Document image
refid# K6J9kqeZNnrBgk1J2DpxxZnK21 page
140 CHAPTER 6 1946 Guide and from kitchens during lengthy periods of cooking, elimination of ; .sources of vapor such as urivented gas stoves, or by local application of heat or insulation to raise surface temperatures. .
Document image
refid# ZJyyNa36D1B2Gez7j5Yjxwb971 page