Refine
Estimated Years 1930-1939Clear
8,921 results foundRefine Search
$8; A m e r ic a n So ciety o f H e a t in g and V e n t il a t in g E ngineers G u id e , 1937 .
Document image
refid# N2DE2aaqn3q31dzKvqL7jMzN81 page
American Society of Heating and Ventilating Engineers Guide, 1937 ht -- hi = the increase in the heat content of the air-water vapor mixture in passing through the apparatus, Btu per pound of dry air = 0.24 (<, - ti) + W, (1059.2 + 0.45 /,) - Wi (1059.2 + 0.45/,) The net quantity of heat added to or removed from air-water vapor mixtures in air conditioning work is frequently approximated by taking the differences in total heat at exit and entrance.
Document image
refid# GKLbee41V8ymbnpqLVyZBXL9v1 page
American Society of Heating and Ventilating Engineers Guide, 1937 .
Document image
refid# zdBRp9nmo3EyjEgrZN972g9L31 page
American Society of Heating and Ventilating Engineers Guide, 1937 A complete study of all of the factors involved in air movement through building constructions would be very complex.
Document image
refid# MJ3L0D2JL74wmwKxgqZ40nv6L1 page
American Society of Heating and Ventilating Engineers Guide, 1937 *" of the air entering the unit with a stipulated refrigerant temperate !
Document image
refid# JrpkmgMqvZq7OJoRd8yvZgqye1 page
American Society of Heating and Ventilating Engineers Guide, 1937 Class 3 Stokers, General Commercial, Small High Pressure Plants The general commercial heating and high pressure plant with boilers burning from 500 lb of coal per hour to 1200 lb of, coal per hour, is a field distinct from the large commercial and industrial field.
Document image
refid# wr3wYKVEmxB8r7Dr6naMYLoGB1 page
American Society of Heating and Ventilating Engineers Guide, 1937 Table 13.
Document image
refid# MJn32QJBpJoMQvaM78o2gr2Vj1 page
American Society of Heating and Ventilating Engineers Guide, 193^ ------------------------------------------- :--------------------\------------------ straighten out, and a pointer motivated by this straightening indicate, the pressure difference on a suitably graduated scale
Document image
refid# DQ3ZL2a847dRxN44X4M59kNQ1 page
American Society of Heating and Ventilating Engineers Guide, 1937 Head..
Document image
refid# evxdxDmX68gXDJo5mKOdqbBRq1 page
International Heating & Ventilating Exposition THE AIR CONDITIONING EXPOSITION Permanent Address--Grand Central Palace, New York, N.
Document image
refid# xj0Qkn1or8mLBxRnLGnn295my1 page
American Society of Heating and Ventilating Engineers Guide, 1937 President tst Vice-Presidents tnd T Treasurer____ Secretary 1910 __Jas.
Document image
refid# peoJ520VvEJO7V5wygyGYYxLk1 page
Heating Ventilating Air Conditioning Guide 1938 Health, 83, 599; (see also Disease Treatment) Heart trouble, 605 Heat, 824 absorbed by building structure, 141 of adsorption, 43 air infiltration equivalent of, 130 capacity, 155, 825 of leader pipes, 378 of condensation, 45 conduction, 821 consumption, 224 content, of air and water vapor, 2 of coal, 166 of dry air, 22 of gases, 661 of saturated water vapor, 23 convection, 821 conversion equations, 833 , demand, factors governing, 133, 241 effects on human body, 54 electrical equivalents of, 750, 834 emission, of convectors, 263, 270 by radiation, 756 of radiators, 263, 270 equivalent, equivalents, 834 of air infiltration, 130 of brake horsepower, 140 electrical, 350, 834 exchanger, 507, 508 shell and tube, 481 flow meter, 817 gain, from fixtures and machinery, 160 for insulated pipe, 735 from outside air, 158 to be removed, 430 infiltration equivalent of, 130 latent, 31, 826, loss, 73, 76 of the liquid, 28, 825 loss, from bare pipe, 719, 721 computation of, 89, 142, .750, 758 cost of. 720 determination of, 133, 140, 229, 753 from ducts, 730 effect of insulation on, 737 from human body, 73, 753, 755 by infiltration, 130, 229 latent, 73, 76 from piping of gas-fired furnaces, 225 by radiation, 61, 753 sensible, 73, 755 to unheated rooms, 118 ventilation, 675 maximum probable demand, 133, 241 of mixing, 47 mechanical equivalent of, 826 produced by cattle, 679 produced by human body, 53 pump, 472, 749 radiant, 753 calculation of, 758 measurement of, 761 types of, 756 radiation, 743, 753 regulation in man, 53, 57 requirements, 229 sensible, 147, 827 of air, 12 loss, 73, 756 of water, 31 solar, 151 sources of, 745, 754 other than heating plant, 140, 149 > specific, 31 total, 22. 829 of saturated steam, 28 transfer, 89 coefficients, 90 rate, 247 Heat (continued) transmission, 89, 754 through air spaces, 91 through building materials, 91 calculations, 89 coefficients, 89, 96 of ceilings. 111 combined, 118 of copper pipe, 721 of doors, 117 of floors. 111 of glass walls, 117 of insulation, 97, 821 of partition walls, 110 of roofs, 114 of skylights, 117 V .
Document image
refid# 8Rne4dQrzMoj9GGBOzYeYzNXa1 page
Heating Ventiuiting Air Conditioning Guide 1938 High Ceilings: Research data concerning stratification of air in build ings are lacking, but in general it may be said that where the increase in temperature is due to the natural tendency of the warmer or less dense air to rise, as where a direct radiation system is installed, the temperature of the air at the ceiling increases with the ceiling height.
Document image
refid# NNpV118QrbXg2QDo87wg81rOR1 page
r Heating Ventilating Air Conditioning Guide 1938 Table 9.
Document image
refid# KGKJ3em4eyVR6vv2bDYEKjw361 page
Heating Ventiuvting Air Conditioning Guide 1938 T Page Taco Heaters, Inc., 342 Madison Ave., New York City, N.
Document image
refid# B8B9z06MkjxGobb2Ldd8n6MMk1 page