Heating Ventilating Air Conditioning Guide 1938
Health, 83, 599; (see also Disease Treatment)
Heart trouble, 605 Heat, 824
absorbed by building structure, 141 of adsorption, 43 air infiltration equivalent of, 130 capacity, 155, 825
of leader pipes, 378 of condensation, 45 conduction, 821 consumption, 224 content,
of air and water vapor, 2 of coal, 166 of dry air, 22 of gases, 661 of saturated water vapor, 23
convection, 821
conversion equations, 833 ,
demand, factors governing, 133, 241
effects on human body, 54
electrical equivalents of, 750, 834 emission,
of convectors, 263, 270 by radiation, 756 of radiators, 263, 270
equivalent, equivalents, 834 of air infiltration, 130 of brake horsepower, 140 electrical, 350, 834
exchanger, 507, 508 shell and tube, 481
flow meter, 817 gain,
from fixtures and machinery, 160 for insulated pipe, 735 from outside air, 158 to be removed, 430 infiltration equivalent of, 130 latent, 31, 826, loss, 73, 76 of the liquid, 28, 825 loss, from bare pipe, 719, 721 computation of, 89, 142, .750, 758 cost of. 720 determination of, 133, 140, 229, 753 from ducts, 730 effect of insulation on, 737 from human body, 73, 753, 755 by infiltration, 130, 229 latent, 73, 76 from piping of gas-fired furnaces, 225 by radiation, 61, 753 sensible, 73, 755 to unheated rooms, 118 ventilation, 675 maximum probable demand, 133, 241 of mixing, 47 mechanical equivalent of, 826 produced by cattle, 679 produced by human body, 53 pump, 472, 749 radiant, 753 calculation of, 758 measurement of, 761 types of, 756
radiation, 743, 753
regulation in man, 53, 57
requirements, 229 sensible, 147, 827
of air, 12 loss, 73, 756 of water, 31
solar, 151
sources of, 745, 754 other than heating plant, 140, 149 >
specific, 31
total, 22. 829 of saturated steam, 28
transfer, 89 coefficients, 90 rate, 247
Heat (continued)
transmission, 89, 754
through air spaces, 91
through building materials, 91
calculations, 89
coefficients, 89, 96
of ceilings. 111
combined, 118
of copper pipe, 721
of doors, 117
of floors. 111
of glass walls, 117
of insulation, 97, 821
of partition walls, 110
of roofs, 114
of skylights, 117
V .
of surface conductance, 92
of walls, 104
of windows, 117, 151
convection equation, 754. definition of terms used, 90 effects of solar radiation on, 151 formulae, 91 through glass, 116, 151 measurement of, 817 in surface coolers, 431 by surfaces not exposed to the sun, 149 symbols used in formulae, 90 tables, 89, 97 through ducts, 730 time lag, 155 utilization, 229
Heaters, direct-fired, 443
for domestic hot water, 799
electric, 741 capacity of, 750 conduction, 743 convection, 743
radiant, 223, 743 space, 223 unit, 437, 743 wall, 222
Heating, (see also'Heat) auxiliary, 749
district, 765 effect of radiators, 266 electrical, 741 elements, electric, 742 fundamentals of, 1 load, 133 medium, 825 radiant, 743, 753 railway air conditioning, 611 by reversed refrigeration, 472, 749 surface, 247, 825
square foot of, 828 symbols, 836
systems,
district, 765 electrical, 741 fan, 409 gravity warm air furnace, 377 hot water, 331, 825 mechanical warm air furnace, 393 radiant, 743, 753 steam, 275, 745
units, blow-through, 411 central fan, 744 draw-through, 411
value, fuel oil, 660 water, 783
Henry and Dalton, law of, 375
Hoods, . axial velocity formula, 637 canopy, 639 for chemical laboratories, 640 design of, 634
. for exhaust systems, 637 of furnaces, 395 open, 639 suction pressures at, 635 velocity pressures at, 637
XIV
Alphabetical Index to Technical Data Section
Horsepower, 825 boiler, 251 brake, heat equivalent of, 140
Hospital air conditioning, (see Disease Treat
ment)
Hot box, 817
Hot plate, 817
Hot water, domestic
control of, 700
load. 253 supply, 797
Hot water heaters, 245, 799
Hot water heating systems, 331, 825 electric, 720 forced circulation, 331, 337 gravity circulation, 331
installation of, 351 mechanical circulation, 333
Hot water piping, 331
Hotels, steam consumption, 234
stokers suitable for, 201 temperatures of, in winter, 134
water supply, 783
Humidification, 10, 499, 825
apparatus for, 503 atomization for, 504
effective temperatures for, 65 methods of, 452 relative humidities for, 68 for residences, 403
systems of, 503 with washer, 501
Humidifier, humidifiers; 466
atomizing, 504
".
with fan systems, 419
high-duty, 504 self-contained, 505
spray, 505 types of, 466, 503
Humidistat, 400, 825
Humidity, 8, 825 absolute, 8, 819
control, 685 railway air conditioning, 612
in drying, 652 in hospitals, 597 for industrial processing, 622, 623 measurement of, 814 optimum, 68 relative, 9, 827, (see also Relative Humidity)
in comfort zone, 63 effect on moisture regain, 625
relation to dew-point, 9
specific, 8. 825
Hygroscopic materials, 626
moisture content, 625 processing of, 627
regain, 626
Hygrostat, 825
Hypertension, 607
Hyperthyroidism, 607, 699
1
Ice, in air conditioning, 407, 454, 496 control of, 701
Inch of water, 825 Induction motor, 707, 710, (see also Motors) Industrial,
air conditioning, 621 apparatus for, 449, 503 calculations, 629
air pollution, 79 control,
biochemical reactions, 628 chemical reactions, 628 crystallization, 629 moisture content, 625 of regain, 624
Industrial (continued) cooling systems, 469 design conditions, 621 drying, 540, 627 electrical heating systems, 748
, exhaust systems, 633, (see also Exhaust Systems) general requirements, 624 heat sources, 141 temperatures and humidities for processing, 622, 623 unit heaters, 444
Infants, premature. 63, 65, 600 Infiltration, 121
average, 126 fuel utilization, 229 heat equivalent, 130 through shingles, 123 through walls, 122 through windows, 124 Inflammability of gases, 81 Institutions, water supply to, 804 Instruments, 807 Insulation, 825 asbestos type,
corrugated, 725, 726 laminated, 727, 728 of boilers, 261 bright metal foil, 94, 95 building, 751 characteristics of, 97, 723 of conduits, 738 of ducts, 732 economical thickness, 736 with electrical heating, 715 heat transmission through, 97, 723 for low temperatures, 733 magnesia type, 724 of piping, 719 to prevent condensation, 141, 734 to prevent freezing, 733 reflective type, 94, 95 rock wool type, 729 of sound, 587 tables, 97. 724 thickness needed, 736 underground, 737 of vibration, 587 Ionization of air, 75 Isobaric, 825 Isothermal, 7, 826
J-K
Joints, expansion, 315, 767 Kata thermometer, 811
L
Lag in heat transmission, 155 Latent heat, 31, 826 .
loss, 72 of water vapor, 12 Lateral exhaust system, 637 Leader pipes, 378 heat carrying capacity of, 379 size of, 379, 389 Leakage of air, 121, (see also Infiltration) Lignite, 166 Liquid, heat of the, 28, 825 Lithium chloride system of adsorption, 46, 492, 493 Load, building factors, 240 cooling, 147 design, 251, 823 heating, 133 hot water supply, 825 maximum, 824 radiation, 824 Low temperature insulation, 733
XV