Refine
Estimated Years 1930-1939Clear
8,921 results foundRefine Search
WTfestostsSSBKs*- ______________________________ . /' American Society of Heating and Ventilating Engineers Guide, 1935 3.
Document image
refid# 6BRepgbmm53JVbOMDLB85rvwE1 page
American Society of Heating and Ventilating Engineers Guide, 1936 When the ventilating fan is started, the relay causes the damper operator to open the outside air damper.
Document image
refid# nk4oMr66b5o5o2rqGeMk2qdYw1 page
American Society of Heating and Ventilating Engineers Guide, 1936 2.
Document image
refid# qmdNaMbDVEqvy6VygGaKK1ewM1 page
American Society of Heating ondtVentilating Engineers Guide, 1936 rooms.
Document image
refid# o0OkBOYjae09jMZB2XNX1LoD1 page
American Society of Heating and Ventilating Engineers Guide, 1936 WILEY, Edgar C.
Document image
refid# 5b3oQ6Q6kkr9ZxdkjyaeLDE0e1 page
American Society of Heating and Ventilating Engineers Guide, 1937 PROBLEMS IN PRACTICE X Dichlorodifluoromethane (Fn) at a saturated temperature of 30 F but superheated 25 F to 55 F is compressed to a saturation temperature of 90 F with a compressor having an overall efficiency of 70 per cent.
Document image
refid# vVy14LM1mMpJdEpEnEe3ErL1w1 page
American Society of Heating and Ventilating Engineers Guide, 1937 1 Table 6.
Document image
refid# dn3M7nQjLMzMBXJowwmyjvnoQ1 page
\ American Society of Heating and Ventilating Engineers Guide, 1937 one for chilled water or brine circulation.
Document image
refid# o9zddvo1ZEqBq17wwzBM5vJe31 page
r American Society of Heating and Ventilating Engineers Guide, 1937 9 Chapter 34--Pipe, Fittings, Welding random lengths of 16 to 22 ft, although when ordered with, plain ends, 5 per cent may be in lengths of 12 to 16 ft.
Document image
refid# qOove6Qe4Z7qZ2J71qQNmEmE1 page
American Society of HEATiNG 'and Ventilating Engineers Guide, 1937 Table 9.
Document image
refid# KzGvRZMOK5xkGq3NpwmdkrOr61 page
American Society of Heating and Ventilating Engineers Guide, 1937 For electrical heating actual heat losses should be figured accurately because the utility company rates and minimum charge items are com monly based on the size of equipment installed, so that cost of operation might be penalized by rule-of-thumb sizing of,the heating equipment.
Document image
refid# zdG5b2JDx0NkjmVJyQB8RxZym1 page
Heating Ventilating Air Conditioning Guide 1938 As is the case with the complete combustion of almost all fuels, the products of combustion for gas are carbon dioxide (COi) and water vapor with just a trace of sulphur trioxide (SOj).
Document image
refid# MG6Q8V2KJKGQgKE1k884g9VaM1 page
Heating Ventilating Air Conditioning Guide 1938 Table 1.
Document image
refid# bBRpJOgw0YZNoaQaqedeNqjqD1 page
Heating Ventilating Air Conditioning Guide 1938 CONTROL OF AUTOMATIC FUEL APPLIANCES It is essential that automatic controls be used with oil burners, gas burners, and stokers in order to maintain even temperatures and provide safe and economical operation of the heating plant.
Document image
refid# e5V4BbDGDJ2EpzxJpmEeo13XE1 page
7 1938Heating Ventilating Air Conditioning Guide expensive in construction, is effective and quite suitable for cathedrals and.large public buildings (Fig. 3).
Document image
refid# ga9J96oma0epEGZ8kqEeNYDge1 page