American Society of Heating and Ventilating Engineers Guide, 1935 Hoyt.
refid# b52gJ4ELnx080djM3Zgz6oM9D1 page
/ American Society of Heating and Ventilating Engineers Guide, 1935 1900 President............... .......................................
refid# jyg6weaQQ4DDgGLevbKvL8VVZ1 page
American Society of Heating and Ventilating Engineers Guide, 1936 Since the difference in vapor pressures is substantially proportional to the difference between the wet- and dry-bulb temperatures the wet- bulb depression) the rate of evaporation is also, for case two, substantially proportionate to the wet-bulb depression.
refid# b5Q2zwEYVv5jnDL6gGXLXE0JO1 page
American Society of Heating and Ventilating Engineers Guide, 1936 Room loudness = 10 logic 10 = 10 db If the sound absorption in the auditorium had been as small as 200 sabines, the sound intensity in the auditorium would have been 10 times as great and the noise level in the auditorium would have been 20 db.
refid# eNRddGQvro91MxVnZj0mye3m1 page
American Society of Heating and Ventilating Engineers Guide, 1936 transmitted noise to any required degree.
refid# wKKQ5pwqD60gX5j2VrpdEMRKB1 page
American Society of Heating and Ventilating Engineers Guide, 1936' For all such buildings the downward system (Fig. 7) offers the best distribution without draft if a sufficient number of exhaust openings are placed under the seats.
refid# G1xYE0RpRm22M52N8LDyqLLn1 page
American Society of Heating and Ventilating Engineers Guide, 1936 The expansion of low pressure steam piping is normally taken as 114 to 1% in. per 100 ft of pipe.
refid# wqObd2Kp3mkYkMoJjpGnoD7kD1 page
of 1936American Society Heating and Ventilating Engineers Guide, found to be 0.622 sq ft.
refid# 82nqGYG3YBLZOq04Q18OYoD9e1 page
American Society of Heating end Ventilating Engineers Guide, 1936 FEBREY, Ernest J.
refid# a4wy1Zrw3X9ZDqvRpYZq1D12e1 page
FILE NAME: Texaco (TEX) DATE: 1934 & 1935 DOC#: TEX004 DOCUMENT DESCRIPTION: Excerpts from PA Dept of Labor Bulletins Asbestosis, Cover Pages Special b u lle tin : -raw COMMONWEALTH OF I'KNN'XVI.VAMA P i t a k t m l n t o r L a b o r a n d i m h 's t u y , I I I M t l O l'T I I C -MUt
refid# qaoB1MVNjo5mz2K1DYBJ0JZqj3 pages
FILE NAME: Engineering (ENG) DATE: 1935 Apr DOC#: ENG004 DOCUMENT DESCRIPTION: Trade Journal Article - Prevention of Occupational Diseases: Other Than Those That Are Caused by Toxic Dust Cl8 256529 C/Yr MECHANICAL ENGINEERING Published by The American Society of Mechanical Engineers V o l u m e 57t N umbbr 4 ' Contents for A pril, 1 9 3 i THE E N G IN E E R AS A C IT IZ E N ..........................................
refid# peewa0DqjjVd5JkNegLwgOOKj7 pages
FILE NAME: Raybestos-Manhattan (RBM) DATE: 1938 Apr 29 DOC#: RBM008 DOCUMENT DESCRIPTION: Letter from Met Life to Vandiver Brown, Johns-Manville 0 \ COPY $ UiDiQPULITjJi LI7 L IBSOhAXCa CO& & Z 1 V 4 Frederick E.
refid# VGddZjxzzoz2yO2RE0Oz2Oomq2 pages
FILE NAME: US Gypsum (USG) DATE: 1938 DOC#: USG070 DOCUMENT DESCRIPTION: 1938 Internal report on dust with cover note to CM Price jJ ^ b i %r.e.M&U. by `fatjUj J Luts^ lLi* j^Ur^A^ y&UAS ^ ' ^ 12 DEFEJNNDpAANNTr'S j^ 4 '1 QSc# .. . 2*.
refid# zzG1RQmMBX1NZd6gmBv1OnEa5 pages
FILE NAME: Raybestos-Manhattan (RBM) DATE: 1935 Oct 19 DOC#: RBM115 DOCUMENT DESCRIPTION: Letter to Met Life RE Asbestos Dust at North Charleston Plant Bridgeport, Conn.
refid# OzGZyr4pV4XLJEBwbOQBgx9Zp3 pages
FILE NAME Insurance Industry INS DATE 1936 Aug 28 DOC INS011 DOCUMENT DESCRIPTION Article from The Eastern Underwriter - Occupational Disease Problems Aired Page 30 August 1936 UNDERWRITER Insurance Section of American Bar Associatio Occupational Disease Problems Aired Call Social Securit Act Unconstit Preventive Measures Considered As Important As Compensa- OPINION OF INSURANCE tion Benefits H.
refid# 44EVKNvzb8zR3w7mrq0e9JB0N3 pages