Refine
Estimated Years 1930-1939Clear
8,921 results foundRefine Search
American Society of Heating and Ventilating Engineers Guide, 1934 effective temperatures giving maximum comfort for persons working have been determined by the A.S.H.V.E.
Document image
refid# BbnZKp54DEwNN13MLXNXEGp41 page
American Society of Heating and Ventilating Engineers Guide, 1934 As the air enters the washer with a low wet-bulb, and as adiabatic satura tion will take place at a temperature close to the entering wet-bulb, considerable cooling of the air can be accomplished but with a consequent increase of the dew-point.
Document image
refid# kDwZ5g3m4orLmvBkMeG48vaGJ1 page
American Society of Heating and Ventilating Engineers Guide, 1934 gradual-acting damper operator on the double mixing damper in the warm and tempered air chambers.
Document image
refid# QvxgyEkQ6N9y0L5p9wre5jk1 page
American Society of Heating and Ventilating Engineers Guide, 1935 v prepared eleven schedules2 for the kiln-drying of practically all kinds, types, and thicknesses of softwoods and hardwoods.
Document image
refid# 5BmGg7y749qL2EQp18Mw23501 page
American Society of Heating and Ventilating, Engineers Guide, 1935 15 What is the Ringelmann Chart Method of comparing smoke densities?
Document image
refid# JN1rjqNqN6Z1bgXyo4rZ5rjZZ1 page
American Society of Heating and Ventilating Engineers Guide Room loudness = 10 logio 10 = 10 db If the sound absorption in the auditorium had been as small as 200 sabines, the intensity in the auditorium would have been 10 times as great and the noise level auditorium would have been 20 db.
Document image
refid# 4vamqGaMwda8LxvqaqB9L4Nr11 page
American Society of Heating and Ventilating Engineers Guide, 1935 be installed to add water to the boiler to maintain a safe level, instead of stopping the burner.
Document image
refid# 5geeXVDQ4ywp3Ov3XaZ9aOE01 page
CODE of ETHICS for ENGINEERS NGINEERING work has become an increasingly important factor E in the progress of civilization and in the welfare of the community.
Document image
refid# Nepa6OgrKDKOYBo9mOmRO6EBb1 page
American Society of Heating and Ventilating Engineers Guide, 1936 humidifier in order to prevent the dew point of the mixture from rising too high.
Document image
refid# zQd0pbRBeq1b5vb40vzgb19rg1 page
American Society of Heating and Ventilating Engineers Guide, 1936 surfaces made available by different manufacturers will have different transmission values.
Document image
refid# J34e205BjxV6pk77oVxLryxR21 page
American Society of Heating and Ventilating Engineers Guide, 1936 low temperature is pumped out of the evaporator and used at the point where it is required.
Document image
refid# r2oLV4kqbav2rXGykYDE5Oq71 page
American Society of Heating and Ventilating Engineers Guide, 1936 first radiator receives the hottest water; the second radiator, somewhat cooler water; the third one, still cooler; and so on.
Document image
refid# 3ew5evD9V7j9qELv2YX2qoj5D1 page
American Society of Heating arid Ventilating Engineers Guide, 1937 Chapter 9--Central Systems for Heating and Humidifying water sprays will become partially saturated (adiabatically) having a moisture con1 toer pound of air equal to saturated air at 41 F.
Document image
refid# 6b3rNM4G6bgwrJ6LBMoDR5db91 page
D iam eter o f B ranch Pipe American Society of Heating and Ventilating Engineers Guide, 1937 368 Chapter 20--Air Duct Design kept within the available pressure difference.
Document image
refid# 2J2MezogNy2OOQpbV1nKdydng1 page
American Society of Heating and Ventilating Engineers Guide, 1937 threads are used.
Document image
refid# 2Ra02ObOYkb3pb52QwMBJqMEp1 page