Refine
Estimated Years 1930-1939Clear
8,921 results foundRefine Search
American Society of Heating and Ventilating Engineers Guide, 1932 the building for recirculation of the air when desired, and a duet system attached, to the fan outlet to convey and distribute the air to various parts of the building to be warmed by the apparatus.
Document image
refid# 068nKeQEmME0Ra4yMEwe3JREb1 page
;:T^ -A American Society of Heating and Ventilating Engineers Guide, 1932 LYMAN, Samuel E.
Document image
refid# 0qgJGy563wgM5J0VDX383DgKm1 page
American Society of Heating and Ventilating Engineers Guide, 1934 and which are constructed of porous brick and lime mortar.
Document image
refid# 2q61V2N0aQevravKNLG39poer1 page
V American Society of Heating and Ventilating Engineers Guide, 1934 Centrifugal Fans and Blowers2 as adopted by the American Society of Heating and Ventilating Engineers and the National Association of Fan Manufacturers.
Document image
refid# kDb8LevnZqrN3pV7aBKQR6bpb1 page
American Society 0/ Heating and Ventilating Engineers Guide, 1935 PROPERTIES OF STEAM Steam is water vapor which exists in the vaporous condition because sufficient heat has been added to the water to supply the latent heat of evaporation and change the liquid into vapor.
Document image
refid# NNej46daYjDz9RnnJbapadyDV1 page
American Society of Heating and Ventilating Engineers Guide, 1935 I" Note.
Document image
refid# 8RbKgdbJQXobzGj7gdG50gdem1 page
American Society of Heating and Ventilating Engineers Guide, 1936 Table 5.
Document image
refid# gDmgBp09wBE14nJrEq0LL4vMq1 page
American Society of Heating and Ventilating Engineers Guide, 1936 Chapter 22--Fan Systems of Heating .
Document image
refid# 1gY4Z9O88KoqGajv9w8jNa27d1 page
of 1936andAmerican Society Heating Ventilating Engineers Guide, Domestic Hot Water Supply Provisions for heating domestic hot water in connection with automatic fuel-burning devices through heat exchangers attached to the boiler are fully described in Chapter 35.
Document image
refid# o23mGEpeR2mvDqxe18q74KbE1 page
American Society of Heating and Ventilating Engineers Guide, 1936 tion, before evaporation can begin.
Document image
refid# Xm8xKKjbjX9L7dv5bmob250g1 page
American Society of Heating and Ventilating ,Engineers Guide, 1936 Meyer Furnace Company, The, 846 HEATING SYSTEMS, Hot Gilbert & Barker Mfg.
Document image
refid# omy6bQka9vw9maR7mjej8OkRE1 page
American Society of Heating and Ventilating Engineers Guide, 1937 W = the weight of the gas, pounds.
Document image
refid# 6BzrQjBm1xqKNk9awQezRG9pm1 page
American Society of Heating and Ventilating Engineers Guide, 1937"' In exhaust ventilating systems where the air column moves toward the fan, noise due to the higher tip speeds and outlet velocities will not be so readily transmitted back through the air column to the building 33 when the air column is moving toward the rooms.
Document image
refid# ZnYxYym7yMMpJp7a3qKKvkXR01 page
American Society of Heating and Ventilating Engineers Guide, 19J7 ' Justification for liberal power provision exists also in the possibility of varying demand due to changes in ventilation requirements, intensity of occupation, and weather conditions
Document image
refid# jggo26VrEX2qMn3dBD44Vp3YQ1 page
American Society of Heating and Ventilating Engineers Guide, 1937 The second method is based on steam consumption data which have been taken from a group of buildings in operation, and the results com puted on a degree-day basis.
Document image
refid# ypGKx94OV93dKRMqOXk7y9OLV1 page