American Society of Heating and Ventilating Engineers Guide, 1928 area of the leader, the designer must make allowances for all other conditions.
refid# MJQe5dLyz4opwNvwoxaoy425z1 page
American Society of Heating and Ventilating Engineers Guide, 1928 Under this condition the capacity of the furnace at the furnace bonnet' per square foot of grate area is 43,300 B.t.u. per hour, and per square inch of grate it is 300 B.t.u. per hour.
refid# g2rjZVKX28ndd0ReqDDBaZX8a1 page
American Society of Heating-and Ventilating Engineers Guide, 1928 Oil Table 1.
refid# j5gk0M5mOarXLnn0bopEyxKk1 page
C.
refid# 995dQg7kZg97Qjdyv48xMjja51 page
American Society of Heating and Ventilating Engineers Guide, 1929 supply to a progressive or lane shower bath, such as is used in connection with swimming pools.
refid# MMkg26jNbNM8q5Bbemv4OoK6M1 page
American Society of Heating and Ventilating Engineers Guide, 1929 TRAPS Traps ordinarily used in connection with heating and ventilating engineering may be divided into the following three types: (1) steam traps, (2) oil traps, (3) air traps.
refid# r63Kb0aDa7L0abzBzqz3VKGEr1 page
American Society of Heating and Ventilating Engineers Guide, 1929 oxygen from the air actually breathed.
refid# 4JEGGNak3V8pRMVEka03JwV3N1 page
American Society of Heating and Ventilating Engineers Guide, 1929 RATING OF AIR CLEANERS Air washers and filters are rated as follows: 1.
refid# 8V0LDyqvBOMqN1kgEwDxa2kMk1 page
American Society of Heating and Ventilating Engineers Guide, 1929 McLEAN, Ivory D., (1924), Pres., (for mail), McLean & Cousens Co., 65 Chandler St., Boston, and 156 Coolidge St., Brookline, Maas.
refid# 7ZNaMmLXQboDY0EndVGz6zmR1 page
of andAmerican Society Heating Ventilating Engineers Guide, 1929 Dayton-- Gibbons.
refid# OEjorO2KjR2r82R9Q3R9v6XkK1 page
22--Coverings for Pipes'and Hot, Surfaces IP- H.
refid# QkrMb40OR9LZObX5ENVqv7oxR1 page
Air Conditioning Frigidaire Sales Corporation Subsidiary of General Motors Corporation Dayton, Ohio Outlets in All Principal .Cities Air Conditioning Division Frigidaire refrigerating equipment has been applied to air conditioning since 1925.
refid# 0J3zVJMq63rB3byDgq1ykQ6DR1 page
PREFACE TO THE 16th EDITION THE general acceptance of the Heating, Ventilating, Air Conditioning Guide as an authoritative source of scientific infor mation on all engineering phases of the industry, has imposed each year since 1922 more and greater responsibilities on the Guide Publication Committee.
refid# 2JRR3ywy7yMdb5EYOONK3j7OL1 page
Pumps American-Marsh Pumps, Inc.
refid# Rpo45q01pB41rxZwN40b0xy8a1 page
EXHAUST SYSTEMS, GENERAL ir COMFORT VENTILATION fortable drafts When people occupying space are seden tary and the only heat produced is that from the occupants themselves, the Ameri can Society of Heating, Refrigerating and Au-Condibonmg Engineers publish ventila tion standards that call for an air motion of not more than 50 fpm The amount of fresh air provided per person for good ventilation vanes with the crowding in the space Total free air space per person and total ventilation required have been subjects of legislation in many places and of local laws, ordinances, and rules of building depart ments, but such codes do not get at the heart of the matter--to assure comfort.
refid# OEK1LQxQR5rwZ9EBqzNjZkvEe1 page