EXHAUST SYSTEMS, GENERAL ir COMFORT VENTILATION
fortable drafts
When people occupying space are seden tary and the only heat produced is that from the occupants themselves, the Ameri can Society of Heating, Refrigerating and Au-Condibonmg Engineers publish ventila tion standards that call for an air motion of not more than 50 fpm The amount of fresh air provided per person for good ventilation vanes with the crowding in the space
Total free air space per person and total ventilation required have been subjects of legislation in many places and of local laws, ordinances, and rules of building depart ments, but such codes do not get at the heart of the matter--to assure comfort.
The object of a heating, cooling, and ven
tilating system is to provide comfort to the occupants, and the feeling of comfort is affected by temperature, humidity, air move ment, and bodily activity, among other things. To express these ideas in a single index of comfort, the "effective tempera ture" (ET) has been defined empirically as a measure of comfort conditions m a single number. It is most applicable to warm atmospheres where radiation effects are not significant In addition to requir-
ing skilled measurement of air flow, the index makes too much allowance for hu midity at low temperatures and not enough at high temperatures
It is fallacious to say categorically that the ideal condition is 70 to 72 F with 50 per cent relative humidity. Actually, ideal values vary from an effective temperature of about 71 for sedentary work to an effec tive temperature somewhere in the high forties for men doing hard manual labor
It was demonstrated" many years ago that men not only work more efficiently at close to the optimum comfort temperature, but also that the accident rate nses rapidly when temperatures either nse or fall from this level
The comfort chart (Fig 28-19) shows the proportion of people who feel comfort able at various effective temperatures It is based on much specialized research and has a number of qualifications The latest ASHRAE Guide and Data Book should be consulted.
Humidity The ratio (expressed in per cent) between the amount of moisture pres ent to the air to the maximum amount that can be held m vapor form at the same temperature and pressure is known as the relative humidity.
Air may be at the proper temperature and still be uncomfortable because it is too dry or too moist If outside air in the win ter is heated to ordinary room tempera ture, it may feel uncomfortable, dry, and cold. The reason is that too little moisture in the air causes excessive dryness of the mucous membranes of the nose and throat and rapid evaporation of moisture from the body Thus a cooler feeling is experienced than would be expected from the tempera ture indicated by the thermometer (This is shown by the curving dashed lines in Fig. 28-18.)
On hot, humid days the air is high in relative humidity, the evaporation of mois-
Fig. 28-18. Shielded wet-and-dry bulb thermometer for determining air temper atures unaffected by radiation.
Courtesy Owens Illinois Gless Company
Osborne, E E and H. M Vernon The Influence of Temperature and Other Con ditions on the Frequency of Industrial Ac cidents. Industrial Fatigue Research Board Report No 19 London, H R M.'s Station ery Office, 1922