Document zzqzaxZJgkderbK9Djbg13GVR

Region 6 Compliance Assurance and Enforcement Division INSPECTION REPORT Inspection Date(s): Media: Regulatory Program(s) 11/28/2017 Water Brine - CWA Company Name: Facility Name: Facility Physical Location: (city, state, zip code) Mailing address: (city, state, zip code) County/Parish: Facility Contact: Sheridan Production Company, LLC Fittstown 34.618317 N, -96.607212 W Drumright, Oklahoma 74030 9 Greenway Plaza, Suite 1300 Houston, Texas 77046 Pontotoc County Jack Thompson 713-548-1000 FRS Number: Identification/Permit Number: Media Number: NAICS: SIC: N/A OKU000863 N/A 21111 1311 Personnel participating in inspection: Kent W. Sanborn 6EN-WR Environmental Engineer (918) 557 - 1615 EPA Lead Inspector Signature/Date Supervisor Signature/Date JERRY SAUNDERS Digitally signed by JERRY SAUNDERS DN: c=US, o=U.S. Government, ou=USEPA, ou=Staff, cn=JERRY SAUNDERS, dnQualifier=0000011249 Date: 2018.01.25 11:27:13 -06'00' Sanborn, Kent Digitally signed by Sanborn, Kent DN: cn=Sanborn, Kent, email=Sanborn.Kent@epa.gov Date: 2018.01.23 12:31:38 -06'00' Kent W. Sanborn Digitally signed by JERRY SAUNDERS JERRY SAUNDERS DN: c=US, o=U.S. Government, ou=USEPA, ou=Staff, cn=JERRY SAUNDERS, dnQualifier=0000011249 Date: 2018.01.25 11:28:06 -06'00' Jerry Saunders Date Date 6ENFORM-019-R7 (2/15/2017) 1 Section I - INTRODUCTION PURPOSE OF THE INSPECTION Sheridan Production Company, LLC / Fittstown Inspection Date: 11/28/2017 EPA Region 6 inspector K.W. Sanborn visited the Sheridan Production Company, LLC oil and gas facility located at the latitude 34.618317 N and longitude -96.607212 W near Drumright, Oklahoma on 11/28/2017 for an unannounced inspection. The inspection was conducted by authority of the Clean Water Act to determine compliance with the Environmental Protection Agency (EPA) regulations. FACILITY DESCRIPTION This facility is known as Fittstown and is a waterflood. Section II - OBSERVATIONS This inspection was a follow up inspection from a previous spill. With a calibrated YSI 30 Pro Conductivity Meter I took Total Dissolved Solids (TDS) readings at the site and in the nearby tributary and Mill Creek. I measured TDS that ranged from 5,000 to 10,000 mg/L in several pools of fluids at the gravel dams prior to Mill Creek. At the entry area from the flow path to Mill Creek, TDS readings ranged from 5,000 to 10,000 mg/L. I observed that the soil at the discharge point had been hauled away. The remediation operations included spraying NitraCal on the surface of the areas the produced water had spilled. I observed trucks were keeping the drainage to the tributary and creek dry. Section III - AREAS OF CONCERN At the time of the inspection, the temporary berms and dams as a part of the remediation operations were not effective at preventing further downstream operations, as some temporary structures were wet during flushing operations. The remediation operations of the flow path and areas were some soil restoration remediation had occurred could erode in rainfall. Section IV - FOLLOW UP Conduct a follow up inspection in approximately three months. Section V - LIST OF APPENDICES N/A 2