CHAPTER 5
1962 Guide And Data Book
elimination. The metal duct connection to
from the
furnace casing and fan housing should be broken by strips
of fire resistant fabric. Motors and mountings must be care
fully selected for quiet operation. Electrical conduit and
water piping must not be fastened to, nor make contact
with the fan housing. Installation of a fen directly under a
return air grille is-usually avoided.
SIMPUFIED METHODS OF DESIGN
Simplified methods of design have been developed for several types of forced warm air heating systems. In general, the specific procedure chosen depends upon the type of system and the type of structure in which it is to be used. In most cases, more than one type of system may be used in a specific structure. It is therefore necessary to first choose the system desired and then determine the applicable design procedure. It is important that any simplified design method used take into account both the pressure loss and the airtemperature drop which occur within the duct system.'
Perimeter-Loop Systems in Concrete Slab Con struction
.The perimeter-loop system,14 s2h3own in Fig. 4, conveys, the warm air through embedded ducts to perimeter diffusers. The air is delivered from the furnace to feeder duct* which extend radially to the loop duct. The air flows through the loop duct to the diffusers. The ducts serve the dual purpose of conveying the warm air and of warming the floor. Al though the design of the concrete slab is not specifically the concern of the mechanical engineer, it is absolutely necessary that he understand the considerations involved- lest im proper construction be used with consequent adverse effect on the performance of the beating system.
It should be understood that when air ducts are enclosed in concrete it is necessary to take certain precautions when putting the system into operation. The slab should be moistcured for not less than seven days and a full 28 day aging
period should elapse before heat is introduced into it. Once the concrete has been properly cured and attains its usual 28 day strength, it is not likely to be damaged by normal duct air temperatures provided the air temperature in the ducts is raised gradually during the first 96 hours of operation. With any type of heating (or with no halting system at all) rapid drying of a green slab may result in the development of cracks in the concrete. For information on slab construction, as well as duct placement, types of duct materials, perimeter edge insulation, eto., see Manual 4 of the National Warm Air Heating and Air Conditioning Association.4 A section of typically installed loop duct is shown in Fig. 5.
Simplified design procedures are contained in Manna] 4. One of these procedures subject to the following limitations: total heat loss-100,000 Btuh, maximum perimeter 210 ft, and maximum length of uninsulated feeder duct 30 ft for area served by one furnace; is the following:
1. Calculate the heat loss for each room using the methods explained in Chapter 25 of the 1961 Gums And Data Book. For suofloor and edge losses, see Manual JI of the National Warm Air Heating ana Air Conditioning Association.
2. Determine the required furnace-bonnet capacity from the heat loss of the building.
3. Locate the diffusers on the plan. For best heating results, if a room has a heat loss of more than 8,000 Btuh or if it has two or more exposed walls, use two or more diffusers. Propor tion the Btuh heat loss of each room among all diffusers in that room.
Table 2.... Diameter of Feeders in Perimeter-Loop System
BfuA per feeder
length of Feeder fa Feet
O-iS Feet
16-30 Feet
Up to 7.999 8,000 to 8,999 9,000 to 10,999 11,000 to 11,999 12,000 to 12,999 13,000 to 17,000
foche* A
6 7 7 7 8
ImAm
6 7 7 8 8 8
4. Locate the feeder ducts. First, divide the heat loss of the
structure by 15,000 to determine the probable number of
feeders. Second, locate the ducts so that they connect with the
perimeter-loop at areas of greatest heat loss or in rooms where
warm floors are particularly desirable. Third, locate the feeder
ducts so that no more than 3 diffusers are in the section of loop
duct between any two feeders. (The final number of feeder
ducts may be larger than that originally estimated.)
5. Determine the size of feeder ducts mwng Table 2. Assume
that the Btuh required by each diffuser wifi be supplied by the
feeder nearest it. Determine the feeder duct diameter from its
length and the total diffuser Btuh delivery carried by it.
6. Determine the total diffuser free area required in each
room using Table 3. Measure the length of feeder duct under
each room. Add to this one-half of the length of the loop duct,
and determine the total diffuser free area required. Apportion
this among all diffusers in the room.
7. The diameter of the loop duct should be uniform and
equal to the diameter of the largest feeder duct. Where feeder
ducts would be more than 30-ft long, they may be shortened by
using a trunk-line distribution system with an
trunk
supplying the feeders. The design procedure is im,lnr to that
used for a conventional trunk and branch system, and is given in Manual 4.*
Perimeter-Radial Systems in Concrete Slab Construcrion
The perimeter-radial system. Fig. 6, is rnnilav to the per imeter-loop system in that the supply ducts are embedded in the concrete slab. The feeder ducts of the radial system ex tend directly from the subfloor plenum to the perimeter dif fusers, and there is no loop duct around the perimeter ol the floor. The feeders do provide floor-warming, but not to the same degree provided by the feeder and loop ducts of a perimeter-loop system. The same considerations of slab con struction and edge insulation apply to both systems.
A amplified design procedure* using fi-in diameter duct
Fig. 6.... Perimeter-Radial System with Feeder Ducts in Concrete Slab or Crawl Space
y/arm Air Heating Systems
65
Table 3.... Minimum Diffuser Free Area Required for Perimeter-loop Systems
Section A. Um TW* Table if length of Feeder which Deliver* Major Portion of Worm Air to Boom b from 2 to 10 Ft
of feeder Poet wdtr Boom Pto* length of Penmefer Oocf Under (om, Ft
s~= ~~
0-9 ft-
IO-I9 Ft.
20-29 Ft.
30-39 Ft. 40-49 Ft.
50-59 a
Total Diffmer Free Areo Bequbod for Boom, Sqoore Inches
60-69 a
0 to 3,999 4,000 to 5,999 6,000 to 7,999 8,000 to 9,999
10,000 to 11,999 12,000 to 13,999 14,000 to 15,999 16,000 to 17,999
18,000 to 19,999 20,000 to 21,999 22,000 to 23,999 24,000 to 25,999
26,000 to 27,999 ' 28,000 to 29,999
30,000 to 31.999 32,000 to 34,000
20
32 27 23 18 43 39 34 29 25 20 55 50 45 41 36 32 27
66 61 57 52 48 43 38
77 72 68 63 59 54 50
88 84 79 75 70 66 61
100 95
91
86 '
82
77 72
111 106 102 97 93 88 84
122 118 113 109 104 100
95
134 129 125 120 116 111 106
145 140. 136 131 127 122 118
156
151
147
142
138- 133
129
168 163 159 154 150 145 141
179 174 170 165 161 156 152
190 185 182 176 173 167 164
Soction B. Um ihb Table if Length of Feeder wfud> Delivers Major Portion of Worm Air to Boom b from 10 to 20 Ft.
0 to 3,999 4,000 to 5,999 6;000 to 7,999 8,000 to 9,999
10,000 to 11,999 12,000 to 13,999 14,000 to 15,999 16,000. to 17,999
18,000 to 19,999 20,000 to 21,999 22,000 to 23,999 24,000 to 25,999.
26,000 to 27,999 28,000 to 29,999 30,000 to 31,999 32,000 to 34,000
23 18 18
36 31 26 21 16 16 49 44 39 34 29 24 19 61 66 51 46 41 36 31
73 68 63 68 53 48 43
86 81 76 71 66 61 56
99 94 89 84 79 74 69
111 106 101
96 91
86 81
123 118 113 108 103
98 93
135 130 125 120 115 110 105
148 143 138 133 128 123 118
161 156 . 151 146 141 . 136 131
174 168 164 158 154 148 144
186 181 176 171 166 161 156
198 .
194
188
184
178
174 168
211 206 201 196 191 188 1S1
Section C. U*e TNj Table if length of Feeder whkh Deliver* Major Portion of Worm Air to Boom b from 20 to 30 Ft.
0 to 3,999 4,000 to 5,999 6.000 to 7,999
8.000 to 9,999
s
. 10,000 to 11,999 12,000 to 13,999 14,000 to 15,999 16,000 to 17,999
18,000 to 19,999 20,000 to 21,999 22,000 to 23,999 24,000 to 25,999
. 26,000 to 27,999 28,000 to 29,999 30,000 to 31,999 32,000 to 34,000
27 42 57 72
86 101 116 131 .
145 160 175 190
205 220 234 249
21 36. 51 66
80 95 110 125
139 154 169 184
199 214 228 243
21 30 45 60
74 89 104 119
133 148 163 178
193 208 222 237
24 18 39 33 54 48
68 62 S3 77 88 . 92 113 107
127 121 142 136 157 151 172 166
187 181 202 196 216 210 231 ' 225
27 42 '
56 71 86 101
115 130 145 160
175 190 204 219
21 36
50 65 80 95
109 124 139 154_
169 184 198 213