Document zzaaKpp3wJ8eB9aNDkReXe1og
306
Controls and Instruments
Leslie Regulators and Controllers
316 GRANT AVE., LVNDHURST, NEW JERSEY
Leslie offers a complete line of regulators, reducing valves and controllers. All units are built to provide the utmost in long-life, reliability and interchangeability. Designs
Leslie Pressure Reducing Valves Automatically maintain a constant reduced pres* sure of steam, air, gas or liquids. Single seated, tight closing. Respond instantly to load changes, Renewable, interchangeable pacts. Stellited seat ing surfaces. Complete overhaul permitted with out removing body from pipe tine. Made in bronze, cast iron, cast steel or cast alloy steels. Sizes V4" to 6*. Other units available for constant differential pressure, unloading and for remote adjustment. Inlet pressures to 1500 p&i steam at 9S0*F. Reduced pressures range from 2 to 600 psi. SEND FOR BULLETIN 5302-B
incorporate the most advanced techniques and are based on Leslie's 60 years of experience in supplying regulation and control equipment
To locate your nearest Leslie factory-trained engineer, look in theYellow Pages under "Valves" or "Regulators." Leslie engineers are part of a world-wide organization with headquarters in or close by these principal cities:
Leslie Low Reduced pressure
Steam Reducing Valves
New simplicity in pressure reducing valve design for steam heating and processes. High accuracy of regulation and years of maintenance-free per formance. Only 2 moving parts. Full capacity bodies . no dirt catching parts . . . ideal for poor steam conditions. Choice of air loaded valve or the spring loaded Leslie-Topper with mechani cal pilot entirely out of the path of steam. Inlet pressures up to 500 psi, 550*F. Reduced pressures from 0 to 299 V4 psi for the air loaded valves or ranges from 2'to 35 psi for Leslie-Toppers. Cast iron: screwed, 125 or 250 lb. ASA Flanged, Bronze: screwed, 150 or 300 lb. Flanged. to 4" for air loaded and Vh" to 2" id Leslie-Toppers.
SEND FOR BULLETINS 561-B AND 582.
Leslie Temperature Regulators
Designed for a wide range of applications. Vary
the flow of steam, hot water or cooling water to
heater or process to automatically maintain con
stant temperature.. Rugged 50*F. or 100*F. ad
justable range thermostatic element. For small
end large flows, direct operated,direct and reverse
acting or with "Duomatic," two-element (pressure
and temperature) control. For driers, fuel oil
heaters, instantaneous and storage heaters, kettles,
' open tanks, ovens, process heaters, degreasing
machines, steam tables, sterilizers, storage beaters,
urns, etc.
SEND FOR BULLETIN 5307
- Leslie Pump Pressure Regulators Maintain predetermined constant or differentia! pump discharge pressures. Accurate control to compensate for frequent or sudden load changes. Assure freedom from hunting, cycling and overregulating.
Available for either reciprocating or turbine driven pumps in a wide choice of body materials; inlet pressures 40*1500 psi and pump discharge - pressure ranges 5*25 psi to 100*2000 psi.
See why most industrial, marine and naval engi neers place thtir confidence in Leslie--the world's most complete line of pump pressure regulators.
SEND FOR BULLETIN 5306
Laslle Diaphragm Control Valves Control flow of steam, liquid, air or gas. Tight shut-off. Operated automatically by air, water or oil pressure supplied from a Control Pilot or from other pneumatic controllers or instrumenta tion. Available in unbalanced or fully balanced types, single and double seared, 14-16' in cast bronze, cast iron, cast steel, aluminum, stainless steel and alloy steels. Primary service ratings to 2500 psi, 1000*F. SEND FOR BULLETIN 5304
Leslie Floatless Level Control
Provides accurate control of liquid level (plus or
mjn>>5 l* water column). Eliminates problems
caused by troublesome linkages, torque tubes,
floats and miffing boxes. Simple design provides
steady, positive, precise control even under diffi
cult conditions. Consists of Level Control Pilot
and suitable diaphragm control valve. Available
with either fixed or adjustable proportioned
bands.
SEND FOR BULLETIN 583
Leslie Control Pilots
Simple mechanical controllers employing constant
supply of clean air, gas, water.or light oil at.
20-22 psi to produce a variable output or loading
pressure of 0*20 psi in response to a level, pres
sure or temperature change, applied to operate a
diaphragm control valve or power cylinder actu
ated valve.
SEND FOR BULLETIN 5303
Leslie Sell-Cleaning Strainers
Recommended to protect all equipment in pipe
line from dirt and foreign matter. Cast iron,
bronze, cast steel, carbon moly, chrome-moly,
stainless and forged steels. Strainers with screwed,
flanged, socket and butt welded connections; sizes
V%* to 10" inclusive. Ratings to 2500 lb. ASA.
Screens furnished in Monel and stainless steel
with various perforations and meshes for steam,
liquid, gas (including liquified gases), air and oil
services.
SEND FOR BULLETIN 5303-A
Controls and Instruments
307
IT1AXITROL company
12200 Beech Hoad, Detroit 39, Michigan
GAS APPLIANCE PRESSURE REGULATORS
High capacity, Straight-Thru-Flow type regulators for low pressure service on residential heating appliances, commercial and industrial gas-fired equipment.
Rubber seat poppet type regulators for precise low-flow control--even the smallest pilot flame. For residential appliances,
MODEL RV 10*
RV-42
NOMINAL
SIZE (INCHES)
OUTLET PRESSURE ADJUST
MENT
INLET OUTLET INCHES ex.
Vi Vi
2-5
Vi H Vi Vi
2-S
2-5 2-5
Vi Vi Vi
3-4 3-4
Vi
Vi Vi Vi
34 3-4
3-4
2-5
K Vi
2-5
3.S-4.5
H y. 3.5--4,5
Vi Vi
2-5
y< * i 1
25
.2-5 2-5
m IVi m IVi
ZVi 33
2-5 2-5 2-5
2-5 25 25
PRESSURE 0R0P CAPACITY H 8.3' wx. Praam Dnp
aD/to
SF 15
81 81 88
81 81 88
81 81 88
126 135
126 135
170
270 270
450 460
676 705
1250 1260
2030 2030
4200 4900
eta/to
Bts/to.
(COBta/caU SBSte/nft
1.7 9 tr Gn MatrGs
11.000
7,450
60.000
60,000 65.000 .
40.500 40.500 44,000
60.000 60.000
65.000
40,500 40,500 44.000
60.000
60.000 65.030
40,500
40.500 44,000
93000 100,000
61,000 67,500
93,000 100.000
61.000 67.500
126.000
85.000
200,000 200000
135.000 135,000
333.000 340.000
225.000 230.000
. 500,200 521.700
338.000 352.500
. 925.000 932,400
625.000 630.000
1.502.200 1.015.000 1.502.200 1,015,000
3.108.000 2.100.000 3.626,000 2.450,000
REGULATION CAPACITIES
Bta/to-80 Bti/eatt, 8-291:G**
(MAXIMUM) (MINIMUM)
17,000
100,000 100.000 100.000
100,000 100,000 100.000
100,000 100:000 100,000
152.000 174,000
152/100 174.000
196,000
310.000 310,000
517,000 527.000
775.000 810/100
1.430.000 1.450.000
2.330.000 _2.330.000
4,850.000 5.650,000
1.700
10/00 10.000 10,000
10.000 10.000 10.000
10/00 . 10.000
10/00
15,200 17.400 15,200
19.600 31.000 31.000
51.700 52.700 77,500 81.000 143,000 145.000 233.000 233.000 485.000
* A.G.A. certified for main burner and pilot load applications.
Pressure Setting: Standard outlet settings are ZS>~ wx. for all models except the following:
RV-IO............................................................................ 3.0in.w.c. RV-41K. RV-41A............... V............................... 4.0 in. w.c. RV-110.......................................................................... 4.0 in. wx.
Upon request, any regulator will be adjusted to any other pres sure within range of standard spring at no extra charge.
Inlet Pressures:
Can be satisfactorily operated at inlet pressures up to one psi. Higher inlet pressures permissible under certain circumstances. Consult factory.
Accessories:
A complete line of accessories including: Maxi-grip rubber sleeve and conventional double-compression vent tube connector fittings; vent limiting orifices; automatic safety vent limiting devices; surge arresters; vent screens. Celon plastic caps.
ELECTRONIC MODULATION FOR FORCED AIR GAS FURNACES
Only practical means of providing in stantaneous modulation of gas flame to heat ItfSs in the home. Re mote .control Seleetrastat (lower left)
sets and senses living area tempera ture. Alt-electronic amplifier located
adjacent to furnace receives signal
from Seleetrastat.
Amplifier (left) powers com bination modulator-regulator valve (right) which replaces conventional regulator on fur nace manifold. Provides infi nite proportioning from foil fire to 1/3 fire; responds in one second to changes as small 1/10 degree. Mo hystere sis--eliminates temperature droop and drift.