Sampling & Evaluating Airborne Asbestos Dust m: - :V . . . . .." 3," ' * . - - . - '>.>)?'' i'v'-p ' if--. ;< .V. f:r< .-.v'-.: ,. ^vr -T. DIVISION OF TRAINING - * ' National Institute for Occupational Safety and Health U. S. DEPARTMENT OF HEALTH. EDUCATION. AND WELFARE Public Health Service V' Health Services and Mantat Health Administration GAF 11434 SAMPLING AND EVALUATING AIRBORNE ASBESTOS DUST Stephen G. Bayer, Physical Science Technician Ralph D. Zumwalde, Engineering Technician January.XS7J g^F lf435 FOREWORD The United States Public Health Service has established a sampling and evaluation procedure for determining airborne asbestos dust exposures. The sample is col lected by drawing air through a membrane filter by means of a battery powered vacuum pump. The filter is changed into a transparent homogeneous plastic mount, and the fibers are sized and counted by phasecontrast microscopy. This method was first used by the Asbestosis Research Council in Great Britain1 and later slightly modified by the U. S. Public Health Service for asbestos dust studies in the United States. It is specified in the emergency asbestos standard as published in the Federal Register on December 7, 1971. UNIFORM procedures must be used for sampling and evaluating asbestos dust if reproducible results are to be achieved. Detailed equipment and procedures used by the United States Public Health Service are described herein. Mention of commercial concents or products does not constitute endorsement by the Public Health Service or the U.S. Department of Health, Education, and Welfare. li GAF 11436 SAMPLING AIRBORNE ASBESTOS INTRODUCTION TO SAMPLING To determine an airborne asbestos concen tration. a sample is collected upon a molecu lar pore filter. This is accomplished with the use of a miniature-battery-poweredvacuum pump which draws air through a celiulose-ester-membrane filter. This sampling unit is attached to a worker and collects an airborne dust sample which is representative of his exposure at his breath ing zone. A description and assembly of the required equipment and a recommended procedure for collecting the sample are in cluded within this report. This procedure is intended to represent a standardized method so that results may be accurate and reproducible. I SAMPLING EQUIPMENT A Pump Description In purchasing a personal sampler we recommend the following guidelines set forth by the Bureau of Mines (Title 30. Part 18, 68 of the Federal Rules and Regulations) and the National Institute for Occupational Safety and Health (Title 30, Part 74). In addition to these guidelines, the following specifications are listed with the intent of minimizing some of the pos sible sampling problems. These specifi cations are a result of several years of extensive field use and laboratory testing: accidental operation during use and protected to keep dust from entering. 4 Flow rate Adjustment - The pump should have an external means of adjusting the flow rate which is indicated by a built-in rotameter. To prevent accidental adjustment, the adjustment should be either rc- ' cessed or covered. 5 Flow Rate Range The pump should be capable of operating in a range of 1.0 to 2.5 1pm. The flow rate should be calibrated within a plus-or-m.inus 5% accuracy. 6 Flow Rate Stability The flow rate should remain within plus-or-minus 0.2 1pm over an 8-hour period when the pump is operated at 1.7 )pm. Not more than two adjustments of the flow rate (due to battery discharge) should be required to maintain accuracy over an 8-hour period. 7 Duration Of Operation - The pump should be capable of operating for 8-hours at a flow rate of at least 1.7 lpm against a resistance of 6" of H2O measured at the pump inlet. 8 Belt Clip The pump unit should be provided with a belt clip which will hold the pump securely to the worker's belt. 1 Weight - The pump should not weigh more than four pounds. 2 Construction - The case and compo nents should be of durable construction and the case should be tight fitting so as to minimize the amount of dust entering the case. 3 Switch - The pump should have an on/off switch mounted on the outside of the case. The switch should be protected against 9 Battery - For continuous operation the pump unit should be equipped with a rechargeable battery. A suitable connection should be provided, so that the battery may be recharged with out removing it from the pump. (See addresses for pump manufacturers). B Sampling Head A 37mm MUtipore field monitor is used as the sampling head. This unit consists of, in order from top to bottom. (1) inlet 1 GAF 11437 >-iirr`iric \irhm-nc -\*ljc.:Og- (2) cap, (3) middle retaining section, (4) ci ilulote ester filter, (5) support pad, (6) base section, (?) outlet plug. These field monitors may be purchased assem bled or in parts (cases, filters, and pads). The complete field monitor assembly is considered to be ready for use upon re ceipt from Millipore Corporation, Addi tional filters and pads can be ordered through Millipore. To aid in eliminating contamination, we recommend banding the two bottom monitor sections with a cellulose band. (See Figure 3 for photo graph of sampling train) C Additional Sampling Equipment The following additional equipment or equal is required to collect a personal sample. Addresses of the commercial concerns which supply all of the mentioned equip ment are given in the address section. 1 Rubber tubing - non-collapsable, 32" to 36" in length and with a l/4" LD. Tubing is connected between the pump and the field monitor. 2 Adapter - leur elip adapter (ILH/L, 1/4" LD. hose connector. Used to connect the tubing to the field monitor outlet. 3 Clip - A plastic band and spring clip arc used to hold the field monitor and hose securely to the worker. This - can be constructed from an 1/2" plastic.band and a #1140 dip. Two are recommended per sampler. 4 Belt - A belt should be available with each sampling unit. This will enable you to attach the pump to the subjects waist in the event he is not wearing a belt. U LABORATORY PREPARATION A Preparing Field Monitors If extensive sampling is to be performed it may be economically advantageous to "Criteria is being developed for certification of other filter types. 2 re-use the field monitor cases. If one would elect to do so, the following steps are recommended: 1 Disassemble the used field monitors and wash them in warm soapy water. Then rinse them in tap water. 2 Lay out the monitor sections in a dust free area and allow to dry. 3 Place a support pad and filter in the bottom section. 4 Aasemble tightly all three sections. Be sura the middle section forms a good seal against the filter. 5 It will only be necessary to replace the inlet plug. t A cellulose band can be placed around the middle and bottom sections. These bands, which shrink upon drying, can also provide a surface for recording data. B Pump Calibration The accuracy of the analyses can be no greeter than the accuracy of the volume of air which is measured. Therefore, it ia necessary to calibrate each sampling pump within + 5% accuracy for any given How rate between 1.0 and 2.5 1pm. The calibration of the sampling pumps would be performed preferably by a primary standard. One accurate and Inexpensive calibrator is the bubble meter. Another good calibrator ia the spirometer. Both are primary standards for calibration and both will produce a high degree of accuracy. If an intermediate standard has to be used, a wet-test meter ia recommended. Rotameters are dis couraged aa calibration instruments be cause of the tendency to give incorrect re sults on the pulsation-type flows encoun tered with these pumpa. The actual calibration set-up will be the same for all calibration instruments. The calibration instrument should be connected in sequence with the filter monitor followed GAF 11438 Wi m JLiiJSftU-.' . <4 u_ / Sa:r.olini; Airhor;.. by the personal pump. Rubber tubing between filter monitor and pump should be of the same kind and length as that used in the field. For reasons of economics, simplicity and accuracy, the bubble-meter method is recommended. The following is a pump calibration procedure using this method. 1 Assemble a ring stand with two adjust* able clamps. 2 Clamp a 1000-2000 ml burette vertically onto the ring stand so that the wide mouth is approximately 4" from the ring stand base. 3 Dispense 100 ml of soap solution into the beaker. 4 Wet entirely the walls of the burette with the soap solution and empty the excess into the beaker. 5 Assemble the sampling train the same as that used in the field. Do net re. move the top cap but only remove the top inlet plug. 6 Adapt the filter to the burette with a short piece of tubing and a leur slip adapter. 7 Touch the mouth of the burette to the soap solution in the beaker. This will form a soap film at the mouth of the burette. 8 Start the pump and time the bubble for one minute. Knowing how many milli liters it traveled in a minute you can convert to 1pm. EXAMPLE: If it takes one minute to travel fifteen hundred milliliters, then the flow rate is one and one half lom. HI SAMPLING PROCEDURE A Theory of Sampling In order to obtain representative samples of the workers' exposure a sufficient v number of samples will be required (<>r each worker. Dust concentrations will vary daily, seasonably, and with tlic weather. To find the low and high dust concentrations it will be necessary t'> collect samples under varying conditions of weather, on different days, and at different times during his working shift. It will be necessaxy when sampling a worker to make note of any changes in his production rate or a change in his work routine. Changes in production rates on near by operations should also be noted. These changes can have a.direct effect upon the workers' exposure.-' NOTE: In accordance with the Threshold Limit Values the exposure for asbestos Is five fibers per ml (fibers greater thsn five microns in length!. This level of exposure is for an eight hour workday, for A 40 hour work week: hence, s sufficient number Of samples are newdwd to permit a time weighted average conten tion throughout a complete cycle of opera tions or throughout the work shift. There also_exists a Ceiling Limit, this limit Places.adefinite boundary in which the concentration should not be permitted to exceed. This limit should not exceed ten, fibers per ml (fibers greater thsn five microns In length) for any 15 minute Mingling wriPti. B Selecting a Subject Cktce a subject has been selected briefly outline the intern of the sampling. Inform him that the personal sampler will not interfere with hit normal duties. Empha sise the importance of continuing to work in a routine manner. A good working re lationship between the subject and your self can help prevent and overcome many inherent eampling problems. To belter approximate the actual average dust concentration the worker should be sampled as long as possible through his 8 hour work shift. To achieve this result a few precautionary measures will be necessary: 1 Some preliminary sampling of the worker will be required. Sample 3 GAF 11439 ::?nl tru* \ irborrtt- Aslwstox tir-e* of 15-30 minu:es at flow rates of 1.3-2.0 1pm arc necessary to determine the dustiness of the operation. A por tion of the sample is then analyzed for the feasibility of counting. (Analytical method described under sample evalua tion!. The feasibility of counting is determined by the ease in which the counters are able to see and size the fibers accurately. The following condi tions could hinder the accuracy of counting: a Collection of a large amount Of asbestos fibers could cause a possible overlapping of fibers which can hinder the differentia tion of 'iber lengths. b Contamination of other airborne particulates. Heavy concentration of particulates hinders the sizing of fibers. Fibers may be partially or entirely obscured from view. NOTE: An Ideal field count would be 1 to 5 fibers/field with a particulate count of i 30. This particulate count is based on those particles whose diameters are<2a and comprise at least 90?. of the total. Cnee you have determined the relative dustiness of the operation, sample the worker accordingly. Remember, sampling time should only be as long as your ability to evaluate the sample -accurately. If short sampling times are required, it will be necessary to take an appropriate number of samples for correlation with the Threshold Limit Value. Placement of Sampler When making sample placements, consider times for breaks and lunch periods in scheduling the placement and removal of samples. Once the sampler has been placed on a subject checkits operation periodically to determine whether the units are operating satisfactorily and if the subject is performing said duties as previously recorded. The following is a recommended procedure for sampler attachment and the recording of data: 1 Attach the pump to the subjects belt, generally at his back. Supply him with a belt if he does not have one. Position the pump so that it does not interfere with the working operations of the subject. 2 Place the field monitor unit over either shoulder and attach the two hose clips to some part of his . clothing. A recommended sampling arrangement consists of one clip positioned near the field monitor and attached to the worker's collar; the second clip is attached to some part of his clothing at his back. This arrangement will hold the field monitor securely in place and help pre vent sampling interference. Make aura the sampling head is located at the workers breathing zone. This area is anywhere on the worker's shoulder or upper chest. 3 Remove the top cap of the field moni tor ao the entire filter is visible. The middle section remains in place hold ing the filter in the monitor. Always make sure the face of the monitor ts in either a horizontal or slightly vertical (downward) position. Never allow the face of the monitor to point upward. 4 Turn on the pump and record the time. Adjust the flow to a given rate and observe the pump to make sure it is operating accurately. 5 Record the following information im mediately to help minimize error: a Filter number b Starting time c Subject's name d Type of operation being performed by subject e Ventilation controls and/or if worker is wearing a respirator. GAF 11440 The following additional information van be filled in at your convenience: a Type of sample b Flow rate c Date d Name of person collecting sample e Production activity in the plant-low, high or Just average f Any remarks about the sample that will help in the future review of the data. 6 Once the sample has been collected the following suggestions are recommended for the removal of the sampler. a Before shutting off the pump, check the unit to be sure it is operating properly. b Check pump and filter numbers with the numbers previously re corded for each location and opera tion. c Turn off pump and record the time. The total time covered by the sample should be expressed in minutes and the total volume of air pumped expressed in liters. d Replace caps on field monitors and store in a clean location. Put ' aside and label as blanks a few un sampled filters. These filters will be used as control samples in your fiber counting. Sampling {Mrbnrri-_jW*.^5104 GAF 11441 EVALUATING AIRBORNE ASBESTOS DUST INTRODUCTION The following procedure describes a tech nique for counting and sizing ssbestos dust which has been collected upon a membrane filter. The filters used in this technique are thirty-seven millimeter diameter cellulosecsthcr membrane filters manufactured by the Millipore Corporation. The slide mount ing technique refers only to this type of filter. The filters are nearly one hundred percent efficient for any asbestos dust, even for fibers with diameters well below the eight tenths of a micron pore size. Filters may be purchased premounted in convenient field monitor cases. Slide mounts of the filters are temporary. The following proce dures and recommendations will produce accurate, reproduceable results if each step is performed exactly as described. I THE MICROSCOPE LABORATORY Dust counting and sizing requires intense concentration. The efficiency of the microscopist will be enhanced by the ease in which he is able to perform his duties; therefore, it is important to supply him with a suitable microscope laboratory. The area should be dust and smoke free, and out of the way of normal traffic. This not only lessens sample contamination, but also pro tects the microscope. Since the counting and sizing procedure is strenuous, the. microscope table should be vibration free, resulting in a sharper microscope image. A chair with adjustable height is essential for the comfort of the microscopist. II MICROSCOPE EQUIPMENT The evaluation procedure requires the use of a microscope to measure the length and width of asbestos fibers. A fiber is distinguished from a particle by having an aspect ratio of at least 3:1. Airborne samples of asbestos contain fibers whose sizes extend far below the maximum resolving power of the best optical microscopes. However, since the U.S. asbestos dust standard is based on fibers five microns and larger, optical mi croscopy can be used for performing the evaluation. Due to the matching index of refraction of asbestos fibers and the mount ing medium, phase contrast microscopy is required for adequate vision. To achieve maximum performance from a phase con trast microscope, it is necessary to in corporate Koehler illumination as an integral part of the optical system. 3-9": Phase Contrast Microscopy A Explanation There may be some speculation as to why a phase-contrast microscope is such an important part of the evaluation process. This feeling nay stem from the fact that light field microscopes have been in use for many years for evaluating dust levels taken with the impinger. In order to Rally understand why a phase-contrast microscope is necessary, a brief comparison of the two types follows. Common light-field microscopy depends upon the fact that light bends when it passes through two substances which differ in index of refraction. This ef fect of bending causes changes in light intensity which gives contrast to the specimen image. Therefore, the image is best developed by using a mounting media with an index of refraction as different from the particles to be viewed as possible. Particulates which are ex amined (under light-field microscopes) when immersed in a media of the same refractive index are practically invisible. Since.the mounting procedure of milli pore type AA filters produces a situa tion where the indices of refraction of the asbestos and of the media nearly match, conventional light field micros copy cannot be utilized. In order to produce image contrast under this cir cumstance, one can select from a 1 GAF 11442 Kvnluaiing Airborne Asbestos Dust variety of contrast-producing methods. These instruments use the wave-form structure of light to produce interference images. Of the several available methods, phase-contrast microscopy is adequate and probably the least expensive. A phase contrast microscope differs from a light field microscope simply by the addition of an annular-ring dia phragm and a phase-shifting element. The annular-ring diaphragm ia located in the condenser. - This diaphragm en ables the condenser to focus a hollow cone of light onto the specimen. An alternative to this ZiraiVe-phase-contrast condenser, is the Heine type. This con denser has a special mirror element to create the light cone. Because of the simplicity of operation as compared to the Abbe-diaphragm-type condenser, the Zernike condenser may be more desirable. The phase-shifting element is located at the back focal plane of the microscope's objective lens. This ele ment is coated with a film to absorb a large percentage of the light passing through it. On the film, a ring of di electric material is placed. This ring advances or retards the green light pass ing through it by one quarter of a wave length (a ninety-degree shift in phase). The image production of a phase-contrast can be summarised as follows: The condenser's cone of light passes through the sample and is then sep arated into two parts: the undiffractcd beam, which is unchanged, and the diffracted beam which is altered be cause it passes through a particle. Next. these two beams pass through the objective lens and into the phaseshifting element where approximately 757 undiffracted light is absorbed and where the diffracted light is shifted ninety degrees out of phase. When the two portions of the original cone of light are recombined, constructive or destructive interference occurs, producing an image having a signifi cant amount of contrast. B Requirements for the Microscope Since the basic principles showing the role of a phase-contrast microscope have been discussed, one might need a guideline for use in purchasing a phase-contrast system. (Figure 1 shows the recommended items). 1 Basic Microscope Body The body of the microscope should have a binocular head. This enables the microscopist to examine the sample through two eyes, which re duces visual fatigue from long-term counting. The fine-focus mechanism should have very little free move ment, since it will be used to examine minute detail which involves a heavy reliance on fine-focussing. 2 Eye Pieces Huygenian type eyepieces are recom mended. The reticle (to be discussed) can be placed on an aperture shelf inside the eyepiece and will have an ideal field area compared to the view. Wide field eyepieces arc highly un desirable because the field area is too small in comparison to the field of view. Some high quality objective lenses (apochromats, fluorites) re quire compensating eyepieces (Huygenian types are available). 3 Reticle The Porton reticle is placed inside the eyepieces. It is a glass disc which contains a rectangle and measuring scale. 4 Stage A mechanical stage ia necessary for positioning the slide. Two knobs control movements in the X and Y directions for sesnning the sample. 5 Illumination Koehler illumination is required for phase-contrast observation. Ulumina- 2 GAF II443 Evaluating Airborne AhiBtr> IXist lion systems may be built into the microscope or purchased as a supple mental unit. The illuminator should have a ribbon filament (or at least a flat-wound coil). The illuminator should have a focusable lens system which projects an enlarged focussed image of the filament onto the substage (microscope) condenser iris. The illuminator must have s field iris, the image of which is focussed in the plane of the sample (Figure 2). Note: The microscopist can buy a phase-contrast kit from most manu facturers. This usually consists of a 10X, 40X and 90X objective, an Abbe condenser having a wheel con taining appropriate annular-ring diaphragms for all objectives, a phase ring centering telescope, and a green filter. Since certain sample may warrant observation at magnifi cations other than that needed here, it is to the microscopist's advantage to purchase the kit. 6 Condenser itW. The microscope should be equipped, tU SAMPLE MOUNTING at least, a Zemilce, Heine, or Abbe con denser containing an adjustable iris diaphragm and annular diaphragm. A field monitor is used for the collection of the sample. This unit consists of three plastic sections with the Alter snd support 7 Objective Lens psd retained between the middle and bottom sections (Figure 3). After the sample has The objective should be approximately been collected, the next process is the 4 mm in focal length (40-4SX) and have preparation of the Alter for analysis. a numerical aperture of at least 0. 65. It must be positive (bright field) con trast. (When several grades of con A Mounting Equipment trast are available, purchase the highest). Experience has shown that certain equij ment is useful for efficient sample 8 Annular-Ring Diaphragm mounting. The following itema are recommended for extracting and placin The condenser must contain an annularring diaphragm which corresponds to a portion of the filter upon the slide. (Figure 4) the objective. 1 Scalpel: A scalpel or scissors is 9 Telescope Microscopes which do not contain a Bertrand lens require a phase-ring centering telescope. Its use permits observation of the back focal plane of the objective, enabling the microscopist to critically center (make concentric) the phase-contrast elements. needed to remove a portion of the filter. Either a pair of micro scissors or a number-ten-curvedblade scalpel works best. 2 Tweezers: A pair of fine-tipped tweezers are used to remove the membrane filter slice from the fiel monitor and place it upon the slide. 10 Filter A green Alter is preferred for a phasecontrast system since the optical de sign is based on the wavelength of green light. Also, since the human eye is most sensitive to green, less eyestrain Is encountered. Beyond that, the red tint produced in poorer lenses is blackened by the filter, producing heightened contrast. 3 Slides: One inch by three inch glas slides are most commonly used. Sample number, data, initials, etc. can be conveniently written on a frosted end slide. 4 Cover Slips: Cover slips are a necessary part of the slide mount and optical system. The shape should be appropriate for the size of the filter wedge. The thickness GAF 11444 Kvihi-'lnn' \i''boi-nc Asbestos Dus^ i!si'il i* dependent on the correction factor built into the objective. Nearly every 4 mm phase contrast objective is opt u nily corrected for a number one and one half (. 17 millimeter) thickness --cover slip. Therefore, improper cover class thickness will detract from the final image quality. 5 j^ens Tissue: To insure cleanliness, use a lint-free lens tissue. This tissue should be used for wiping mounting tools and for cleaning slides and cover slips. 6 Class Rod: A spatula or fire-polished glass rod is needed to spread the mounting solution on the slide. ` 7 Wheaton Balsam Bottle: Tills special* glass container has a glass top which hinders contamination of the solution. A glass rod is included for dispensing the solution. U Mounting Procedure A very important part of the sample evaluation is the mounting process. This process involves a special mount ing media of prescribed viscosity. The viscosity is designed so as to expedite filter clearing and Itamper particle migration. Once the sample has been mounted, nn elapsed time of approxi,, moldy fifteen minutes is needed before the sample is ready for evaluation. 1 Preparation of the Mounting Solution The mounting solution consists bf two chemicals, dimethyl pthalnie and diethyl ox'alate. which are combined in a one to one ratio by volume. These chemicals are poured into a Wheaton balsam bottle. Five hundredths of a gram of clean filter material per milliliter is added to reach the pre scrib'd viscosity. It will be neces sary to stir the solution until the filters have dissolved and a homo geneous mixture is formed. Twenty milliliters of mounting solution will prepare approximately three hundred samples. The normal shelf life of the mounting solution is about six months, after which time fiber shaped crystals may begin to form. The crystallizing process can be retarded by keeping the solu tion in the Whetton balsam bottle and in a cool place. 2 Sample Mounting Keep in mind that cleanliness is important! A clean working area will help achieve better results. ' The following steps should be fol lowed when mounting a sample: Step 1 Clean the slides and cover slips with lens tissue. Remember to lay the slide dawn with the frosted end up. It is a good practice to rest one edge of the cover slip on the slide and the other edge on the working surface. By doing this, you keep the bottom surface (the one which contacts the filter) from becoming contaminated. Step 2 Wipe all of the mounting tools clean with lens tissue and place them on a clean surface (i. e. , lens tissue). When mounting a aeries of filters the scalpel or scissors should be wiped clean before cutting each sample. Step 3 Using the glass rod which is supplird with the Wheaton balsam bottle, drop a small amount of mounting so lution onto the center of the slide. Do not touch the slide with the rod, this car. contribute to the contamina tion of the mounting solution. It may be necessary to make adjustments on the quantity of solution which is used. The correct amount will result in the solution extending only slightly beyond the filter boundary. If the quantity is greater than this, particle migration will occur. Step 4 Using the spatula or a supplemental glass rod, spread the mounting media GAF 11445 Evaluating Airborne A oc IfciM into a triangular shape. The size of this triangle should coincide with the dimension of the filter wedge. Step 5 Separate the middle and bottom sec tions of the field monitor case, ex posing the fragile filter. Cut a triangular wedge from the filter using the scalpel or microscissors. The size of the wedge should approximate one-eighth of the filter surface. Step 6 Using the tweezers, grasp the filter wedge in the area which was sand wiched by the monitor case sections. Place the wedge, sample side up. upon the mounting media. Step 7 Using tweezers, pick up the cover slip and place it on the filter/media combination. Press lightly on the cover until it makes contact with the now-dissolving filter. Once this contact has been made, do not re position the cover slip. Step 8 Label the slide with the sample num ber and current date before proceed ing to the next filter. Step 9 IV CALIBRATION The asbestos dust count procedure consists of judging fiber length by comparison with calibrated circles, and counting all fibers of a certain size within a certain field area. This is dons with the use of a Portor. reticle (Figure 5). The Porton reticle is a rec tangle consisting of two squares. The square on the left, divided into six rec tangles, is ths counting area. The square on the right contains a logrithmic scale which extends the measuring range beyond that of the circles. A . Ths Porton reticle is easily placed inside, a Huygenian-type eyepiece where it rests" on the built-in aperture. A split ring is included with the reticle to aid mounting when there is no aperture present. In cer tain eyepieces, the aperture may be moved up and down making it possible to slightly vary the magnification. The reticle should be kept clean, since dirt on the reticle is in focus may complicate the counting and siz ing process. The Porton reticle is useless for counting unless it Is properly calibrated with a stage micrometer. A stege micrometer is a glass slide with a scale unit which can be teen only under a microscope. Most stage micrometer ecalea are about two millimeters long and are divided into units of one-hundreth of a milli meter or ten microns. (See Figure 6 cali bration of Porton reticle with stage micro meter). Before calibrating, the microscope must be set up according to the manufactur ers directions. The sample should become transparent after about fifteen minutes. If the fil ter appears cloudy, it may be necessary to again press lightly on the cover slip. Step 10 Discard the sample mount after five days If it has not been counted. Crystals which appear similar to asbestos fibers may begin to grow at mounting solution/air interfaces. They seldom present any problems if the slide is examined before five days. In any ease, stay away from the filler's edges when counting and sizing. The mieroscopist may find the following will hold true for most microscopes. The en larged image of the illuminator's filament must be focussed either on the condenser's fully closed iris or at the back focal plane of the objective lens. It is important that the phase-shifting element ring and annular diaphragm be concentric. Most microscopes have centering controls which allow manual correction if necessary. Next, close the illuminator's field iris, and focus the con denser's image in the sample's focal place. Each eyepiece-objective-reticle combination on your microscope must be calibrated. Should any of the three be changed (disassem bly, replacement, breakage) the combination GAF 11446 r\:i!:Hing Airborne Asbestos Dust should be re-calibrated. For proper ealibrstion, the following procedure should be close* Iv followed. Wilh-the ION objective in place, put the stage micrometer on the mechanical stage focus, and center the image. Change to the 4 mm (40-45X) objective and adjust the first scale division to coincide with the left boundary of the porton rectangle. Count the number of divisions from here to the right boundary of the rectangle, estimating any portion of the final division. <See Figure 6) This measure ment represents two hundred "L" units. Divide by 200 to find "L`L_Thts unit is inserted into the formula D * where "D" is the circle diameter, "L." is the unit of length, and "N" is the circle number (indicated on the reticle). Since the circle diameters vary logrithmically, every other circle doubles in diameter. For example, number three is twice the diameter of number one; number four is twice the diameter of number two. After all of the circle sices have been de termined the field area must be calculated (lOOM2". This completes the reticle calibra tion for this specific objective - eyepiece - reticle combination. Figure 7 shows s cal ibration card containing information on three objective lenses and an illustration of a Porton reticle. V COUNTING AND SIZING Place the slide in the mechanical stage end * position the center of the wedge under the objective lens and focus upon the sample. Nearly all of the partieulatee (particles and fibers) will be found in the upper ten to fif teen microns of the filter surface. When counting and sizing, frequent use of the fine focus control will help to insure that nothing is missed. Start counting from one end of the wedge and progress in a straight tine to the other end (count in either direction from circumference to wedge tip). To determine the average fiber deposition per field it is necessary to examine twenty random field areas or one-hundred fibers whichever it last. Random fields are selected, without looking into the eveoieces. by slightly ad vancing the slide with the mechanical stage control. A field area is the left half of a Porton reticle (rectangles one through six in Figure 5. 6 The following rules are necessary to achieve comparable results. Rule 1 Only size fibers with greater than or equal to a 3:1 aspect ratio. Rule 2 Only count fibers greater than five mi crons in length. (Be as accurate as possible in sizing fibers near the five mirror cut off) Rule 3 Count and size fibers inside the field area. Rule 4 Size and count fibera which cross two pre-selected adjacent sides and have one end inside the field area. VI CALCULATION OF CONCENTRATION Asbestos dust concentration may be calcula ted from the following formula: c . (A. F. C. - B. A. F. C. KFiltcr Area) (Field Area)(Volume)(1000) C Concentration in fibers/milUliter A. F. C. Average fiber count for twenty field areas B. A. F. C. Average fiber count of blank or control filter. (It is subtracted to eliminate the error of back ground contamination.) Filter Area 355 mm for 37 mm diameter (the portion of the Mlllipore filter which la exposed when mounted in the field monitor case). Field Area The area of the counting field in a calibrated Porton reticle expressed In mm1. Volume Samples air volume (flow rate X time) 1000 Converts liters toV milliliters 11447