Document zzO6EaZNn47JzqEVyGv6x9Epg
Georgia-fticific
Firestop gypsum sheathing
incombustible exterior sheathing
G-P Firestop gypsum sheathing is an incombustible gypsum product with a treated core and a specially formulated water repellent paper on both sides. G-P Firestop gypsum sheathing meets the requirements of ASTM C79-67 as well as Federal Specification SS-L-30C, Type II, Grade W, Class 2, including require ment for water resistance. This eliminates the need for building paper (except where required by local building code).
G-P Firestop gypsum sheathing is manufactured in widths 2' and 4'. The 2' wide sheathing is made with tongue and groove edges to provide a structurally strong and stable wall. V-tongue and groove edges fit snugly, minimizing wind infiltration. The 4` wide square edge sheathing applied vertically, completely eliminates the need for corner bracing. It is designed to meet racking test requirements of FHA Technical Circular 12.
data Thickness: Vz " and s/s " Length: 8', 9' Width: 2', 4' Edges: 2' x 8'--V-Tongue and Groove
4' x 8' and 4' x 9' Square Edge (on special order only)
1 HR. fire rated system 1 layer of 5/s" G-P Firestop wallboard interior; 1 layer of Vz" Gypsum Firestop Sheathing and plywood or wood siding on the exterior. Insulation not required to meet the fire ratings.
packaging Twin mounted
advantages
Non-combustible. Low cost! Only one-half the price of some
competitive type sheathing. Only 3% installation waste and
uses fewer nails.
Average house can be sheathed in about 8-man hours.
Four-foot wide sheathing eliminates need for corner bracing.
Easily scored and snapped. Water resistant core and face
paper.
product use May be used on both commercial and residential buildings, wherever strong, stable walls are desired.
application V-Tongue and groove edge--Apply panels horizontally at right angles to studs with grooved edge down. Break end joints on succeeding courses so that end joints in following courses are not in line. All V-joint edges shall be in close contact.
Square edge--Panels shall be applied vertically with long edges parallel to the studs. Use length necessary to span distance between sills and plates or other structural members. Center long edges on studs.
nailing and stapling Use galvanized roofing nails with a 3/8" to 7/16" head, 1-3/4" long. Staples -11 gage or -16 gage, 7/16" x 1-1/2" with divergent points may also be used. For 4' wide sheathing space, 4" o.c. around edges at top and bottom plates, and 8" o.c. in the field. For 2' wide sheathing, 8" o.c.
Gypsum Division, 900 S.W. 5th Avenue, Portland, Oregon 97204
SGP 0025976
F$10 1/72 5 3669
S P E C IA L BOARDS
I
i
I I I
i !
\
SGP 0025977