534 CHAPTER 37 1959 Guide, appropriately. When data on degree days are available these may be used in the calculation of average outdoor tempera* ture for use in Equation 2 or 3. (See definition of.degree day, Chapter 4.) It may be noted that a portion of Equation 3, (t -- t*)N will, when divided by 24, correspond exactly to the degree days for the period, provided that t = 65 F, the usual basis for calculating degree days (see discussion of degree days in following sections). Some engineers substitute degree days for the period, multiplied by 24, for the value of (t -- U)N in Equation 3: Since this amounts to the baas for degree-day calculations, assuming that t = 65 F, some allowance is thus made for the fact that F will frequently be overestimated, when H is taken as the maximum, or design, heat load. Example 1: A residence building is to be heated to 70 F from 6 am. to 10 pm. and 65 F from 10 pm. to 6 am. The calculated hourly heat los is 120,000 Btu per hour based on 70 F inside at --10 F outdoors. If the building is to be heated by metered steam, how many pounds would be required during an average heating season? Solution: The heating value of steam may be taken.as 1000 Btu per lb, and since it is purchased steam, the efficiency can be asumed as 100 percent. Assume average outdoor temperature as 36.4 F. The average inside temperature is: (16 X 70) + (8 X 65) _____ - 685 F. Substituting in Equation 1 120,000(685- 36.4)5088 F 1.00170 - (-10)11000 243,000 b' Example 2: What would be the fuel cost to heat the building in Example t during an average beating season, using stokerfired bituminous coal at $14.00 per ton having a calorific value of 13,000 Btu per lb, msuming that the seasonal efficiency of the system is 65 percent? Solution: Substituting in Equation 1 p- ggj? - 28,800 lb. 0.65170 - (-10)113,000 .V The fuel cost is then (28,800 -% 2000) (14) =$20100 Example S: What will be the estimated fuel cost per year of heating a building with gas, assuming that the calculated hourly heat loss is 92,000 Btu based on 0 F, which includes 26,000 Btu for infiltration? The design temperatures are 0 F and 72 F. The normal heating season is 210 days, and the average outdoor temperature during the heating season is 36.4 F. The upmdd.i efficiency will be 80 percent. The heating plant will be thermo statically controlled, and a temperature of 65 F will be maintmned from 11 pm. to 7 am. Assume that the price of gas is iv Pr 106^00 Btu of fuel consumption, and disregard the loss of heat through open windows and doors. Solution: The average hourly temperature is (72 X 16) + (85 X 8) . . 24 The maximum hourly heat loss is 9.7 F. H ~ 92,000 Btu. The seasonal beat loss is 92,000(69.7 - 36.4) X 24 X 210 100,000 X 0.80 X (72 - 0) 2697 hundred thousand Btu.' The estimated seasonal fuel cost will be 2697 X $0075 - $20200 It should be noted that savings from night setback may not result as calculated. Room temperature may not decrease and combustion efficiency may be poor during morning pickup* Several time-saving procedures have been devised for quickly estimating the hourly Btu loss of one- and two-story residences in order that fuel estimates can be predicted more quickly from Equation 1. A graphical method of calculating heat losses has been developed11 which makes possible a quick solution if the gross wall, ceiling, or floor areas and re spective transmission coefficients are known. The Federal Housing Administration has originated a short-cut formula for residential heat loS3 determinations which makes use of the floor area and three selected trans mission coefficients. The formula was developed to apply to detached houses approximately rectangular in shape with total exterior door and window areas equal to about 25 per cent of the floor area, and with a floor area not greater than about 1500 sq ft. Equation 4 is for a one-story residence, and Equation 5 is intended for two-story structures. where * A(G +u.+ Ut + Ut){U - l.) A(G + 1.21/. + 0.5U, + 0.5U,)(U - t.) (4) (5) Hi = beat loss From one-story residence, Btu per hour. Bi = heat loss from two-etory residence, Btu per hour. A = floor area, square feet, measured to the inside faces of enclosing walls and is the sum of the following areas: (1) all the area on each principal floor level; (2) the area of all finished habitable attic rooms, including bathrooms, toilet compartments, closets, and halls; (3) all other areas intended to be heated and not lo cated in the basement. G > glass and infiltration factor for ordinary construction: (0.45 for no weatherstripping or storm windows), (0.40 for weatherstripping), (0.30 for storm windows with or without weatherstripping). Um -- coefficient of transmission for outside wall. Ut " coefficient of transmission for ceiling. (Jf ** coefficient of transmission hr floor. U indoor design temperature, Fahrenheit degrees. t. a outdoor design temperature, Fahrenheit degrees. Notes for application of Equations 4 nd 6. 1. The calculation oi beat loss from heated spaces into ad jacent spaces such as attics, basementless areas, heated or untested garages shall be based on the assumption that the temperature of such adjacent spaces is the same as the out door design temperature. 2. For all floors over basements or other warmed spaces as sume Ut -- 0. 3. For structures having concrete slab floors laid on the ground , a modified application oi the formula may be made. Assume Uf~0 and calculate the heat loss in accordance with the check formula. Then add the slab loss determined in accordance .with the procedure developed by the National Bureau of Standards end described in Building Materials and Standards Report 103. 4. No basement area is to be included in the formula calcula tion. If finished habitable rooms in the basement are to be heated, the additional heat loss should be calculated separately and added to the amount obtained by the formula. Both the graphical method" and FHA formulas, when used within the limitations established, have been found to give reasonably accurate results for the average residence, but if precise estimates are required, the heat loss should be calculated as outlined in Chapter 12. In the case of gravity warm air heating installations, tbe load was formerly expressed in square inches of leader pipe which can be converted into Btu per hour by multiplying the square inches of leader area by 111,167, and 200 for first, second, and third floors, respectively. Estimating Fuel Consumption for Space Heating 535 DEGREE-DAY METHOD This method is based on consumption data which have been taken from buildings in operation, and tbe results have been computed on a degree-day basis. While this method may not be as theoretically precise as the Calculated Heat Loss Method, it is considered by many to be of more value for practical use. The amount of heat required in a building depends upon tbe outdoor temperature, if other variables are eliminated. Theoretically it is proportional to the difference between tbe outdoor and indoor temperatures. The American Gas As sociation** determined from records in the heating of resi dences that the gas consumption varied directly as the de gree days, or as the difference between 65 F and the mean outdoor temperature. In other words, on a day when the mean temperature was 20 deg below 65 F, twice as much gas was consumed as on a day when the temperature was 10 deg below 65 F. For any one day, when the mean tempera ture is less than 65 F, there are as many degree days as there are degrees difference in temperature between the mean temperature for the day and 65 F. Degree days may be cal culated on other than the 65 F base for use mainly for ware house and other industrial spaces in which temperatures to be maintained are considerably below the 68 to 72 F range. They are listed in a later section of this chapter. Studies made by tbe National District Heating Associa tion* of the metered steam consumption of 163 buildings located in 22 different cities, and'served with steam from a district heating company, substantiate the approximate cor rectness of the 65 F base chosen by the gas industry. Table 2 lists the average number of degree days that have occurred over a long period of years, by months, and the yearly totals for various cities in the United States and Canada. The number of degree days for United States cities were calculated by taking the difference between 65 F and the daily mean temperature computed as half the total-of the daily maximum and the daily minimum temperatures. Tbe monthly averages were obtained by adding daily degree days for each month each year and dividing by tbe number of days in the month; then totaling the respective calendar monthly averages for the number of years indicated and di viding by the number of years. The total or long term yearly average degree-day value is the summation of the 12 monthly averages. Degree days for Canadian cities were supplied by the Canadian Meteorological Division of the Department of Transport, and were computed from the mean temperature normals on record for the various stations. (See Note c. Table 2.) Any attempt to apply the degree-day method of estimating fuel consumption for less than one month would be of very little value. It should be noted that this method of calcula tion is based on a long term average and cannot be expected to coincide with any single year in calculating fuel require ment. Individual yearly degree-day. calculations may vary as much as 20 percent above and below tbe long term aver age. If the degree days occurring each day are totaled for a rea sonably long period, the fuel consumption during that period as compared with another period may be assumed to be is direct proportion to the number of degree days in the two periods. Consequently, for a given installation, tbe fuel con sumption can be calculated in terms of fuel used per degree day for any sufficiently long period, and compared with similar ratios for other periods to determine tbe relative operating efficiencies with the outdoor temperature variable eliminated. Such, results should be used with some reservation since it is possible to have wide variations, for example, as between early and late winter periods.14 Computation and Application The general equation for calculating the probable fuel con sumption by the degree-day method is: F^UXNXDxC/ (6) where P = fuel consumption for the estimate period. If ** unit fuel consumption, or quantity of fuel used per (degree day) (building load unit). N 0 number of building load units (when available, use calculated hourly heat loss instead of actual amount of radiation installed). D -- number of degree days for the estimate period. Cf temperature-correction factor from Table 3. ' Table 3 .... Correction Factors for Outdoor Design Temperatures* Outdoor Dea'gs Imp F.... -20 -10 0 +10 +20 Correction factor......... 0.778 0.875 1.000 1.167 1.400 * Tbs mottiplien in Tibi* t,wtuck m tush tar mDdciimue* utd low tor mid refioca, an not ia error as might appear. Tb# oaitflfuxw in TUiler 4, i, od 9 re per aqoue foot <4 radiator or tbocaand Bio beet Ion per decree dap. For equiva lent heatinc eeeeooa,in warm bare lover deuicti hnt looea and Q-* radiator qttantitiee tban tboee in eold cities. Consequently, tbe util C*aro in quantity of fuel per (square foot of radiator) (decree day), b larger for warn boa)itiim than ter colder reckons. Since the northern sties have more radiator eurtaee pet given budding and a Mrlw vr-V*"1 decree-day total than cities in the south, tbe total fool per ifm will be larger for tbe northern oty. Values of N depend on the particular building for which the estimate is being prepared and must be found by survey ing plans, by observation, or by measurement of the build ing. Values of U for use in this equation are the unit fuel consumptions per degree day, obtained as a result of the col lection of operating information and listed in Tables 4, 5, and 6. Attention is directed to the nature of these units in the next following sections. Unit Fuel Consumptions per Degree Day The quantity of fuel used per degree day in a given heat ing plant ean be reduced to a unit basis in terms of quantity of fuel or steam per degree day per thousand Btu hourly heat loss-at design conditions. A less frequently used basis is quantity of fuel per (degree day) (square foot of floor area). In fact any convenient unit can be used to relate the con sumption to the degree day and to the building. The choice of these units requires explanation, and some discrimination and judgment. If the volume basis is used, the net heated space is preferable to the gross building cub age, since gross cubage includes outer walls and certain por tions of attic and basement space that are usually unheated. In the absence of data on net heated volume, a value of 80 percent of the gross volume may be used to obtain the esti mated net heated volume. The volume basis has been rather widely used primarily because it is simple to apply. In in dustrial buildings it is usually easier to obtain the correct IL