Document zzLxVN21O57mD3a36O5EDG75m
A-C FULL VOLTAGE-MAGNETIC Price Additions for Optionol Features
115
co "O
O =9^1
Item Description
' So' o-; > m
00 0 1 2 3 4 5 6-7-8
Enclosures
1 Start, Stop Pushbutton or Run-Off-Auto Selector Switch in cover of NEMA 1........... $8. $8. $8. $8. $8. $8. $8. $33.
All other enclosures............................................................................................... 2 Pilot light in cover of NEMA 1................................................................................ ...
All other enclosures............................................................................................... ... 3 Breather and Drain in NEMA 7 and 9..................................................................... ... 4 Forward, Reverse, Stop Pushbuttons in cover of NEMA 1........................................ ...
NEMA 4, 5-12 and 9............................................................................................... ... 5 Size 0, cast aluminum, NEMA 4;with 2 Coil Overload Relay:
22. 22. 22. 22. 22. 22.
15. 15. 15. 15. 15. 15. 27. 27. 27. 27. 27. 27.
6. 6. 6. 6. 6. 6. 40. 40. 40. 40. 40. 40.
50. 50. 50. 50. 50. 50.
50. <
27.
O
ID CO
27.
57. o m > 67. *oo:i^s-mS2
Cat. No. 9586H6018--Reset Button in cover.................................................
N/C
9586H6019--Start, Stop Pushbuttons in cover................................. ... N/C ...
... ...
9586H6020--Run-Off-Auto Selector Switch in cover........................ ... N/C ... ... ... ...
__ Or* t"gomC5
Size 1, cast aluminum, NEMA 4; with 2 Coil Overload Relay:
Cat. No. 9586H6131--Reset Button in cover................................................. 9586H6132--Start, Stop Pushbutton in cover.................................. ...
N/C ... N/C ...
...
...
...'
...
9586H6133--Run-Off-Auto Selector Switch in cover........................ ... ... N/C ... ... ... ... --
Panel Equipment
6 OControl Circuit Transformer--Single and Dual Voltage
Primary.................................................................................. 60 or 50 cycles
27. 27. 38. 56. 68. 77. 77.
25 cycles
41. 41. 57. 84. 102. 102. 102.
With 100 watt extra capacity............................................. 60 or 50 cycles
48. 48. 62. 78. 88. 98. 98.
25 cycles
72. 72. 93. 117. 132. 147. 147.
With 200 watt extra capacity............................................ 60 or 50 cycles
65. 65. 81. 97. 107. 107.
With 300 watt extra capacity............................................ 60 or 50 cycles
82. 82. 100. 116. 126. 126.
7 Separate Control Circuit.........................................................................................
N/C N/C N/C N/C N/C N/C
8 Substitute Dual Voltage Coil -- Per coil....................................................................
2. 2. 2. 2. 2. 2.
9 Substitute Special Voltage or Frequency Magnet Coil -- Per coil..................................
3.
3.
4.
5.
7.
8. 10. 11.
Standard Voltages
.110,115,120, 208, 220, 230, 240, 277,380 (50 cycles), 440, 460, 480, 550,600
Standard Frequencies
25,50, 60 cycles
"D >
C/i
-O3H3 O
o
33
O
Overload Relay
10 Standard Duty and Fast Trip Overload Heater Coils, Addition or
Deduction Each coil........... ......................... ........ ............ ........................... 1.50 1.50 1.50 150 1.50 1.50 1.50 1.50 11 3 Coil Overload Relay with Standard Trip Heater Coil.............................................. 4. 4. 4. 4. 4. 4. 40. 70. 12 Substitute Fast Trip for Standard Trip Overload Relay............................................ N/C N/C N/C N/C N/C N/C N/C N/C 13 Substitute Automatic Reset for Manual Reset.......................................................... N/C N/C N/C N/C N/C N/C N/C N/C 14 Thermal Overload Relay with Normally Open Contacts, or
Normally Open and Normally Closed Contacts..................................................... 4. 4. 4. 4. 4. 4. 4. 4.
Auxiliary Contacts
15 Auxiliary Contacts--For Field Installation............... ...............................................
See Tab e Below
16 Extra Auxiliary Contacts--Factory Installed
Normally Open or Normally Closed.................................................
11. 11. 11. 11. 11. 11. 33.
Normally Open and Normally Closed.................................... ....... ... 22. 22.
r-- O
3>0
S -h2
3
AUXILIARY CONTACT KITS
Contacts Normally Open...........................
Size 0
10933HI
Catalog Numbers
Size 1
10933: HI
Size 2
10933H7
Size 3
10933H7 .
Normally Closed......................... H2 H3 H8 H9
Normally Closed Late Opening... H4 H4 H1Q H10
Normally Open & 0 Normally Closed................. H5
H6
-- ...
Size 4 & 5 10933H7 H21 H10
...
p.
$6. 6 68.
O Transformers in NEMA 1, 4, 5 or 12 enclosures have fused secondary.
Both normally open and normally closed contacts must be used on the same side of the line.
MAXIMUM NUMBER OF EXTRA AUXILIARY
CONTACTOR
Catalog No.
Size 0&1
9586 9589 & 9591
9656
9658 & 9659
2 2 1 1
Size 2&3
3 3 2 2
Size 4&5
4 3 3 2
A maximum of two normally closed contacts may be added per contactor. Only one normally closed late opening con tact Is permissible per contactor.