Document zzLxVN21O57mD3a36O5EDG75m

A-C FULL VOLTAGE-MAGNETIC Price Additions for Optionol Features 115 co "O O =9^1 Item Description ' So' o-; > m 00 0 1 2 3 4 5 6-7-8 Enclosures 1 Start, Stop Pushbutton or Run-Off-Auto Selector Switch in cover of NEMA 1........... $8. $8. $8. $8. $8. $8. $8. $33. All other enclosures............................................................................................... 2 Pilot light in cover of NEMA 1................................................................................ ... All other enclosures............................................................................................... ... 3 Breather and Drain in NEMA 7 and 9..................................................................... ... 4 Forward, Reverse, Stop Pushbuttons in cover of NEMA 1........................................ ... NEMA 4, 5-12 and 9............................................................................................... ... 5 Size 0, cast aluminum, NEMA 4;with 2 Coil Overload Relay: 22. 22. 22. 22. 22. 22. 15. 15. 15. 15. 15. 15. 27. 27. 27. 27. 27. 27. 6. 6. 6. 6. 6. 6. 40. 40. 40. 40. 40. 40. 50. 50. 50. 50. 50. 50. 50. < 27. O ID CO 27. 57. o m > 67. *oo:i^s-mS2 Cat. No. 9586H6018--Reset Button in cover................................................. N/C 9586H6019--Start, Stop Pushbuttons in cover................................. ... N/C ... ... ... 9586H6020--Run-Off-Auto Selector Switch in cover........................ ... N/C ... ... ... ... __ Or* t"gomC5 Size 1, cast aluminum, NEMA 4; with 2 Coil Overload Relay: Cat. No. 9586H6131--Reset Button in cover................................................. 9586H6132--Start, Stop Pushbutton in cover.................................. ... N/C ... N/C ... ... ... ...' ... 9586H6133--Run-Off-Auto Selector Switch in cover........................ ... ... N/C ... ... ... ... -- Panel Equipment 6 OControl Circuit Transformer--Single and Dual Voltage Primary.................................................................................. 60 or 50 cycles 27. 27. 38. 56. 68. 77. 77. 25 cycles 41. 41. 57. 84. 102. 102. 102. With 100 watt extra capacity............................................. 60 or 50 cycles 48. 48. 62. 78. 88. 98. 98. 25 cycles 72. 72. 93. 117. 132. 147. 147. With 200 watt extra capacity............................................ 60 or 50 cycles 65. 65. 81. 97. 107. 107. With 300 watt extra capacity............................................ 60 or 50 cycles 82. 82. 100. 116. 126. 126. 7 Separate Control Circuit......................................................................................... N/C N/C N/C N/C N/C N/C 8 Substitute Dual Voltage Coil -- Per coil.................................................................... 2. 2. 2. 2. 2. 2. 9 Substitute Special Voltage or Frequency Magnet Coil -- Per coil.................................. 3. 3. 4. 5. 7. 8. 10. 11. Standard Voltages .110,115,120, 208, 220, 230, 240, 277,380 (50 cycles), 440, 460, 480, 550,600 Standard Frequencies 25,50, 60 cycles "D > C/i -O3H3 O o 33 O Overload Relay 10 Standard Duty and Fast Trip Overload Heater Coils, Addition or Deduction Each coil........... ......................... ........ ............ ........................... 1.50 1.50 1.50 150 1.50 1.50 1.50 1.50 11 3 Coil Overload Relay with Standard Trip Heater Coil.............................................. 4. 4. 4. 4. 4. 4. 40. 70. 12 Substitute Fast Trip for Standard Trip Overload Relay............................................ N/C N/C N/C N/C N/C N/C N/C N/C 13 Substitute Automatic Reset for Manual Reset.......................................................... N/C N/C N/C N/C N/C N/C N/C N/C 14 Thermal Overload Relay with Normally Open Contacts, or Normally Open and Normally Closed Contacts..................................................... 4. 4. 4. 4. 4. 4. 4. 4. Auxiliary Contacts 15 Auxiliary Contacts--For Field Installation............... ............................................... See Tab e Below 16 Extra Auxiliary Contacts--Factory Installed Normally Open or Normally Closed................................................. 11. 11. 11. 11. 11. 11. 33. Normally Open and Normally Closed.................................... ....... ... 22. 22. r-- O 3>0 S -h2 3 AUXILIARY CONTACT KITS Contacts Normally Open........................... Size 0 10933HI Catalog Numbers Size 1 10933: HI Size 2 10933H7 Size 3 10933H7 . Normally Closed......................... H2 H3 H8 H9 Normally Closed Late Opening... H4 H4 H1Q H10 Normally Open & 0 Normally Closed................. H5 H6 -- ... Size 4 & 5 10933H7 H21 H10 ... p. $6. 6 68. O Transformers in NEMA 1, 4, 5 or 12 enclosures have fused secondary. Both normally open and normally closed contacts must be used on the same side of the line. MAXIMUM NUMBER OF EXTRA AUXILIARY CONTACTOR Catalog No. Size 0&1 9586 9589 & 9591 9656 9658 & 9659 2 2 1 1 Size 2&3 3 3 2 2 Size 4&5 4 3 3 2 A maximum of two normally closed contacts may be added per contactor. Only one normally closed late opening con tact Is permissible per contactor. <s> ill 00 oo "OH "OH =m =m_!_ c/3 00 Ci ~ ZE >2 OO -- C/3 ^ 03 ^ DISCOUNT SCHEDULE ICO CUTLER'H AMMER 115