bcc: Roger Hatton Geo. Fague 0. L. Mellon St. Louis St. Louis Akron December 20. 1973 Mr. Dick Pickens TIMKEN COMPANY Dueber Avenue Canton, Ohio Hear Pick: Confirming our phone conversation of December 18, 1973, I have attached data coopering Pydraul 312, 312A, 312C, and 65E in an oxidationcorrosion test 791-3508 Method. This data shows that Monsanto has main tained consistence of fluids during the removal of the chlorinated portions changing to phosphate esters. Dick, 1 aw looking forward to discussing this data with you on January 4, 1974. If I can be of assistance prior to ny visit, please contact me at (216) 666-4111. Very truly yours. CFSihn oncl: cc: Mr. Joseph H. Menster Purchasing T1taken Coepany Dueber Avenue Canton, Ohio C.F. Reger Sales Representative Specialty Products Croup ]>cc|_ Dick Pickens!data for Fyrtech T-290 in ASTM D-2272 was 15 min as compared to P-312C at 31 minutes. C.F.S. 0066161 TOWOLDMON0056359 Oxidation-Corrosion Test Results 791-3508 Method 250F. - 168 hr. Fluid O Metal wt. change, mg/cm Magnesium Aluminum Cadmium Iron Copper Viscosity change at 100$ Acidity, TAN, initial final Pydraul 312 -0.01 -0.01 -0.05 0.00 -1.89 +36$ 0.30 1.38 Pydraul 312A +0.01 +0.01 -0.01 +0.02 -0.04 +5$ 0.04 0.40 Pydraul 312C -0.02 0.00 0.00 -0.01 -0.04 +12$ 0.03 2.22 Pydraul 65E +0.04 +0.03 +0.03 +0.01 -0.07 +5$ 0.05 0.09 0066162 TOWOLDMONOQ56360