Document zzEj6BN73OwBpyzNO2ovLNmm7
Wood Treating
FROM (LOCATION)'
G. B. MILLS, WTCC
C C:
DATE
:
APRIL 13, 1970
SUBJECT
:
REFERENCE
:
ANALYSIS OF DEFECTIVE LOT OF L1QU1 D NOXTANE 120
D. R. DILL REQUEST OF 4-7-70
"">D'R. EDWARD M. EMERY, JFQ DR. ROBERT E. KELLER, JFQ MR. H. J. HORNER, WGK
R. M. MORRISS D. R. DILL R. F. SIMMONS R. E. STUTZ
IT IS REQUESTED THAT ANALYSES BE PERFORMED FOR QUANTITATIVE DETERMINATIONS OF PENTA 60, BORON, AND MERCURY ON THE SUBMITTED SAMPLE OF LIQUID NOXTANE 120.
IT WOULD BE HELPFUL IF QUANTITATIVE DETERMINATIONS COULD ALSO BE MADE FOR ETHYLENE GLYCOL, ISOPROPYL ALCOHOL, AND DI ETHYLENE GLYCOL MONOMETHYL ETHER IN THE SAMPLE.
A CONTROL SAMPLE IS ALSO SUBMITTED. THIS HAS THE COMPOS-r* IT ION ON A WEIGHT PERCENT BASIS OF:
DIETHYLENE GLYCOL MONOMETHYL ETHER ......................... 3.44 %
PHENYL MERCURIC LACTATE......................................................... 1.30
SODIUM HYDROXIDE------- --............................................................. 7.47
SODIUM TETRABORATE DECAHYDRATE.................................... 11.43
PENTA 60..............................................................................................27.60
ETHYLENE GLYCOL......................................................................--1 2.1 1
ISOPROPYL ALCOHOL..........................................................
5.45
WATER..................................................................................................... 31 .20
TOTALS
100.00
THE EQUIVALENT PERCENT OF MERCURY AS METAL IS 0.209. AND FOR BORON IS 1.296
WE WILL APPRECIATE IT IF YOU CAN EXPEDITE THE TESTING AS CIRCUMSTANCES HAVE PUT US IN SOMEWHAT OF A BIND PRODUCT I ON WISE.
MANY THANKS,
gS\N 2-988A7
STLCOPCB4068761
- 241*43
'W)
n-n
I2.I4T 3.44
z
X
0S\N 29848
STLCOPCB4068762