948 CHAPTER 50 1940 Guide Table 1. Demand Weights or Fixtures in Fixture Units* Fixture or Group* Occupancy Type of Supply Control Weight in Fixture Units' Pedestal urinal---- ----------------- Hotel or restaurant_____ Flush valve for closet_________ Flush tank for closet- 10 5 10 5 3 2 4 4 3 4 6 3 1, ,, .2 2 8 6 2 .. 2- .3 3 ' For supply outlets likely to impose continuous demands, estimate continuous supply separately and add to ^FbHixtures not dstedTweighta may be assumed by comparing the fixture to,a listed one using water in similar quantities and at similar rates. The given weights are for total demand. For fixtures with both hot and cold water supplies, the weights for maximum separate demands may be taken as H the listed demand for the supply. Fig 1. Estimate Curves for Demand Load' No. 1 for system predominantly, for flush valves.: No. 2 for system predominantly for flush tanks. ;e: "60--------- 60 TOO 120 KO . ICO 160 ,200 . -.FIXTURE: UNITS ... Fx<j. 2. Section or Fm-1 ON Enlarged Scale .220 2*0 " Water Services 949 Table 2. Performance Requirements or Water Meters* Size In. H m 2-______________ 4_ 6_________ ___ __________ Normal Test-Flow Limits GPM . 1 to 20 2 to 34 3 to 53 5 to 100 8 to 160 28 to 500 48 to 1.000 Minimum Test-Flow GPM Ku 1*1 2 7 12. * American Water Works Association Standards: Registration. The registration on the meter dial shall indicate the quantity recorded to be not less than 68 per cent nor more than 102 per cent of the water actually passed through the meter while it is being tested at rates of flow within the specified limits herein under normal test flow limits: There shall be not less than 90 per cent of the actual flow recorded when a test is made at the rate of flow set forth under minimum test As copper tubing is not likely to retain interior incrustation to any serious extent. Fig. 5 may be used 'safely to estimate carrying capacity of copper tubing*. SIZING COLD WATER SUPPLY PIPING In order to apply the foregoing principles to the sizing of the supply pipes in the usual up-feed .system, it is necessary to ascertain the minimum pressure in the street mainl and from this should be subtracted the minir mum pressure required for the operation of the topmost fixture. (A pressure of 15 psi is ample for flush valves but reference should be made to the manufacturers' requirements. A minimum of 8 psi should be allowed for other fixtures.) The pressure differential thus obtained will be avail able for overcoming pressure losses in the distributing system and in over coming the difference in elevation between the water main and the highest fixture. The pressure losses in the distributing system will consist of the pressure losses in the piping itself, the pressure losses in the pipe fittings, and the pressure losses in the water meter, if any. Estimated pressure losses for disc-type meters for various rates of flow are given in Fig. 6. Flow limits Table 3. Allowance in Equivalent Length of Pipe for Friction Loss in Valves and Threaded Fittings Diameter of FIint.ting 90 Deg Standard Ell Ft H-------- K-----------------K i IKIK9 -- 2K3 3K-----4 $ 6_. .1 i 2 2.5 3 4 5 7 8 10 12 14 17 20 Equivalent Length-of Pipe for Various Fittings 45 Deg Standard .Ell Ft 90 Deg Side Tee Ft Coupling or Straight Run of Tee Ft 0.6 1.2 1.5 1.8 2.4 3 4 5 6 7 8 10 12 1.5 3 4 5 ,6 7 10 12 . 15 18 21 25 30 ' 0.3 0.6 0.8 0.9 1.2 1.5 2 2.5 3 3.6 4.0 5 6 Gate Valve -Ft 0.2 0.4 0.5 0.6 0.8 1.0 1.3 L6 2 2.4 2.7 3.3 4 Globe Valve Ft- 8 15 20 25 35 45 55 65 80 100 125 140-j 165 Angle Valve Ft 4 8 12' ' 15. , 18 . 22 28 34 : 40 50 55 70 80