Document zoqVB9L2BEXn6Ry8YRE44pdJB
D'TA steet
PLAINTIFF'S EXHIBIT CIIR-182
ATR-C^RS'E ;V'ST
date
location
OUST CONCENTRATION* IS' M. p. P.C. F.
Maximum Allowable Concentration - Asbestos
5.0
2-8-65 .7-8-65 2-S-65 2-8-65 7-8-65 2-10-65 2-10-oS 2-10-65 2-.'-65 2-:;-.i5 7-:'.-'j5 7-10-65 2-10-65 2-10-65 2-10-65
Drake lining "rinding - West side grinder Brake lining grinding - East side grinder Inspection operation - West side bench Inspection operation - East side bench - West side employee Number 2 saw - gener.'-l air Nunber 1 saw - general air Number 3 saw - general air Number 4 saw - general air First floor mixer - general air Dry mixer on balcony - South side mixer Dry mixer on balcony - North side mixer Dry mixer on balcony - South side mixer dry mixer on balcony - South side mixer Dry mixer on balcony - South side mixer Dry mixer on balcony - North side mixer
2.7 1.5 2.4 1.4 1.5 2.0 3.4 1.4 7.0 3.0 1.5 5.7 5.4 3.3 4.3
2-12-65 2-12-65
Old Building - undercoat sealer mixer: Dixie clay added to mixer General air immediately following addition of clay
24.0** 10.0**
* M.P.P.C.P, means million particles of dust per cubic foot of air ** Maximum allowable concentration is 20.0 m.p.p.c.f. for this type of dust.
Samples were collected with a Mines Safety Appliances Company Midget Impinger at breathing zone level.
TOLUENE VAPOR
LOCATION
TOLUENE VAPOR IN PARTS PEE MILLION PARTS Or AIR
Threshold Limit Value
200
Unloading asbestos-sol.vent mixture from Daker-Perkins mixer into a wooden box
Shoveling asbestos-solvent mixture from the wooden box into extruder hopper
Breathing zone level of employee transferring sheet material to drying rack
Moving drying racks into oven drying area
1500-1800 1100-1800
200-900 800-1000
Toluene vapor concentrations were measured with a J and W Aromatic Hydrocarbon Indicator Model SS at breathing zone level.
<--rr 2
METHYL 'T:!YL K :Tf'NV "`POR
location
mek vapor in parts per
million pacts on air
Threshold Limit Value
200
Employee applying coating to brake liners Placing brake liners on drying rack Pushing drying rack to ventilated area
80-220 55-190 800-1030
MEK Vapor concentrations were obtained with a J and W Aromatic Hydrocarbon Indicator Model SS at breathing zone level.
MONOCHLOROBEN2SN'E VAPOR
LOCATION
NONOCIT.OROBEN2ENE VAPOR IN PARTS P~R MILLION PARTS OF AIR
Threshold Limit Value
75
Placing brake liners on drying rack - 5 minute average Employee applying coating to brake liners - we could not sample the area because the srnpling probe is not of sufficient length to reach from outside room to work area.
60
Vapor concentration was determined with a Davis Halide Meter.
ILLUMINATION LEVELS
LOCATION
ILLUMINATION IN FOOT CANDLES
Old Building: Area where K 124 and H2S drums are filled Area where K 1011 and K 120 drums are filled Northwest of Bandbury machine - 2 bulbs out of order Roller end of above machine Balcony - loading of Bandburymachine Balcony - above K 1011 and K120drum filling operation Farrell roller Adamson United roller Bench top Aisleway - storage area Loading dock area- near drums to be loaded - some bulbs
out of order Receiving dock area under balcony
4-6 4-8 4 4-6 4-6 24-28 4-8 50-60 30-42 4-6 7-12
6-10
DA.TA SHEET ft3
ILLUMINATION LEVELS LCONT'D)
LOCATION
ILLUMINATION IN
Warehouses Center of area South area Aisleway
16-20 8-16
1S-22
New Building: Brake liner grinding - West grinder
- East grinder Inspection operation - East side bench Number 2 saw
"ixing area - balcony Mixing area - first floor Coating operation
50 50 125 50 46 20-25 30
Illumination levels were measured with a Weston Foot-Candle Meter model 614.
EXHAUST VENTILATION
LOCATION
AIR VELOCITY IN FPM
Halcony - North mixer - capture velocity - South mixer - capture velocity
First floor - North mixer - capture velocity - South mixer - capture velocity
Coating conveyor line - capture velocity Hood above drums where H2S coating placed in drum -
face velocity ilood above drums where K 1011 and K 123 packaged -
face velocity Solvent room - diethylenetriamlne addition - capture velocity
50-70 50-35 less than 50 less than 50 50-150 140-150
230-300
150-170
SANITARY FACILITIES
LOCATION
URINALS STOOLS BRADLEYS 'WASH BASIN FLOORS WALLS SHO'/ERS
New Building
13
3
O.K. Q.K.
6
Old Building:
Second floor
331
O.K. O.K.
4*
Receiving and shipping 1
1**
1***
O.K. O.K.
dock
* Flat top lockers provided. We recommend slant top lockers because easier to clean
** One toilet seat found to be broken
** No powdered hand soap dispenser provided.