February 22, 1957
Koppers Company, Inc* Mr. Jack Hyde Chamber of Commerce Building Pittsburgh, Pennsylvania
SU3JECT: Weirton Steel Company Weirton, West Virginia 12* Sintering Machine
Dear Jack:
Enclosed are two sets of heat transfer calculations for the insulated straight wall portions shown on our drawing P-21223-A* The insulation in these areas will consist of 3 3/V* insulating castable (H-W 85 or equal) and 1 1/2" of our Detrick Block*
I have also enclosed copies of the conductivity curves for the block and castable. I took "K" factors for the brick from Harbison-Walker*s "Modern Refractory Practice", Pag 339j 1950 Edition, using the same values as for 70% Alumina. According to A1 Pierce this is acceptable, as 60^ Alumina is close enough to the 70% in conductivity.
As you can see, I end up with an outside skin tempera ture of 211 F#
Please let us know if there is anything more we can furnish you in the way of information.
Very truly yours,
M. H. DETRICK COMPANY
WEE:GS
Enc.
i
i
Walter E. Eliman
\