Document zoa7xV8Ed6eRnM2R7vEb8wy0m
DISTRIBUTION
CED SECTION MANAGER
ced project manager
__
P* Stevens
R W. Peterson
0. R. Bailey J. M. Depp M. Dmytryszyn R. E. Emling F. W. Enoch F. J. Holzapfel R. W. Kaltenrieder F. P. LaBelle R. E. Lenz Russell L. Miller E. Negro C. L. Parish A. B. Terry
(2)
W. J. Burkett
R. R. Cook/J. R. Fullgraf
R. E. Howard
.
CEA NO.
1430
PRODUCT
_
PROGRESS REPORT
AR NO.
DATE
1430
Jan.
19,
1968
Aroclors
.
Increase Aroclor Capacity
DIVISION
Organic
PLANT
Anniston
DIVISION REPRESENTATIVE
___ _ J~ V?~. '
ORGANIC DIVISION
H. C. Carder J. Cresce R. J. Stratmeyer H. L. Williams
SCOPE
Aroclor production facilities at Anniston will be expanded by the addition of tankage for storage and for the preparation of blends, drumming facilities in a new building (to be expanded on another project, CEA 1452, into a product warehouse), new and larger flakers for solid Aroclors and for biphenyl in the same building, and packaging equipment for flaked products. Tank truck loading and a new track spur with tank car loading and unloading facili ties are included.
- '.W
THIS DOCUMENT IS THE F?0?srty C- MONSANTO CO-.'-ANT and T-E recipient is ."PONSiBlE pop its Sa'FE<E-nO AND D-S
POSITION. IT contains COfiflCSSTiAi. iN=0:,-AT ON A'-i'C-. MUST mot SE REPRODUCED t rvEALcO TO unauthO^tp-.
OR SENT OUTSIDE THE COMPANY WITHOUT P?C,5iR AUTHORIZATION.
DSW 392491
WATER PCB-SD0000051381
-2-
PfnrittrJ
Aroclors_________________________________
LocationAnniston
Title_________Increase Aroclor Capacity_______________________________________________
Data Tabulated As Of
n^cember 31. 1967
CEA No. 1430
AR No.
Appropriation
Current Estimate Date of Estimate Expended & Committed Spent This Month Scheduled Completion On Schedule?
MS 1.400 MS 1,307 See Below
December. 1967 MS 248
MS 20 July and October, 1968
No
Process Design, % Complete Mechanical Design, % Complete Construction, % Complete % Expended & Committed Design Manpower Construction Manpower
--
Last Month 70 35
--
13 10 --
This Mo. 74 50
--
19 12 --
SUMMARY:
Design for the tank farm is complete and that for the flakingpackaging area is underway. Field .work is late getting started because of underground problems. Relocation of the offending sewers threatens a major delay in project completion.
FIELD WORK:
Site preparation has been delayed by problems in repairing the 36" storm sewer which passes through the tank farm-warehouse area. Plant efforts at repair (with CED assistance) appear fruitless; in addition, uncover ing a portion of the 24" process sewer in the same area now indicates this sewer is in poor repair also. CED (utilities) is preparing a recom mendation for division action. Unless a temporary arrangement can be devised, relocation or rebuilding of these sewers will entail a major project delay.
TANK FARM:
Design is essentially complete. leased. The model is finished. ment specifications are issued. oriented now.
Foundation and steel, drawings are re Piping drawings are underway. Instru The critical path is completely field
FLAKER-PACKAGING:
.
Work on the study model layout is underway. Steel and foundation design is given priority. Details of material handling can be examined at more length. The vendor of two flakers is on strike. We are looking for used equipment and alternate vendors. Due to the sewer delays we may be able to wait longer before changing flaker plans.
CAPITAL ESTIMATE:
$93,000 was transferred to CEA 1452 - Aroclor Warehouse, for a common building to enclose flaking-packaging. The $1,307,000 capital reported as "current estimate" is equivalent to the original scope.
R. W. Peterson Acting Project Manager vo
DSW 392492
WATER PCB-SD0000051382