Document zo2gGXO50K6XOnBJJNy2pbm6R
684
CHAPTER 48
1960 Guide
conditioning one method of control includes a thermostat located in the passenger section to start and stop the refriger ation compressor. If the compressor is driven by the bus engine a clutch is provided which can be energized or de energized by operation of the thermostat. On systems em ploying a compressor, driven by a separate engine, automatic means of starting and stopping the engine are controlled by the thermostat. Modulating control of engine driven compres sors may be accomplished by automatic control of the engine throttle by a thermostat in the passenger section. Some sys tems provide for continuous operation of the compressor when cooling is required, the compressor being manually started by the operator. Temperature in the interior of the bus is maintained by reheating the air from the cooling coil. Automatic control of temperature is provided by a thermo stat in the passenger space or the return air to the blower which operates a modulating valve on the engine coolant supply to the reheat coil.
AUTOMOBILE SUMMER AIR CONDITIONING
The basic components used for automobile air condition ing are fundamentally the same as in any stationary air conditioning system using the vapor compression cycle. For automobile application the source of power is always a major obstacle to overcome. The best solution to date for automobile applications is to operate the condensing unit by belt drive from the car motor and then control the variable refrigerating capacity caused by the variable car motor speed by suitable means.
One to seven or more horsepower are required. Compres sors must be capable of operating at speeds of 4000 to 5000 rpm to last in this service. Refrigeration capacity re quired is about 1V4 to 1Vi tons. Radiant heat, as well as high conduction beat gain due to single-glased large glass areas, and lack of adequate insulation in car bodies require this much capacity. Proper air distribution to avoid undesirable drafts on passengers also requires careful design. Air distribution fans and electrical controls secure power from the car's electrical system which in some cases may require heavier generators and batteries to handle the load. Most systems weigh about 200 lb or `less.
Early designs, and many current ones, have the cooling units installed in the rear of the car with the cooled air in troduced through the package shelf at the rear of the pas senger comportment. Cooled air is then distributed with or without ducts. Warm air is returned through a grille in the package shelf, or below the rear seat, thence through a filter into the "cooling units. Refrigerant lines from con densing unit to cooling unit are carried from the engine compartment to the luggage compartment along the car frame under the body.
Performance at opan-road speeds has been very sat isfactory (even with early systems--when they were oper ating properly). Twenty percent or more outdoor air should be supplied, especially if passengers smoke. This air may be picked up by scoops on the ride of the car or cowl, carried into the cooling unit, mid mixed with returned warm air from the car.
Car temperature control, compressor capacity control to compensate for the variable compressor speed, and prevention of ice formation on the evaporators (a common fault of early systems)' are accomplished by bypassing compressor discharge gas into the low-pressure ride of the system, or cycling the compressor with a magnetic
clutch. The solenoid bypass valve or a magnetic clutch is electrically operated by a thermostat, usually controlled by the return air to the cooling unit. The bypass is opened or the compressor stopped when the air gets too cold.
A recent development is a complete factory-assembled system, charged with refrigerant and ready to run, which is dropped into position ahead of the fire wall of the car and bolted into place. Flexible suction, liquid, and dis charge lins are used to connect the refrigeration com ponents together. This facilitates initial installation. It aim simplifies removal for service and maintenance and eliminates the necessity to open the refrigeration compo nents to tiie atmosphere with resultant loss of refrigerant or infiltration of moisture into the system.
This system combines winter heating with summer cooling. It also permits use of all or limited quantities of outdoor air, with or without heating or cooling. Outdoor air is taken in through cowl openings. This air is then pulled through a combined heating and cooling *6oil as sembly by a fan inside the car on the fire wall. Cooled air is discharged from adjustable nozzles on the dash inside the car. Hot air for heating is discharged onto the floor as with conventional car heaters. Dampers change the air distribution from heating to cooling, and dash controls activate or shut off either heating or cooling.
Temperature control, prevention of evaporator icing and compensation for variable compressor spaed are con trolled by a thermostat with bulb in the air leaving the evaporator. This cycles the compressor on a magnetic clutch.
Public acceptance of current offerings has been excellent. Performance has been very satisfactory. What service difficulties have been encountered have been readily cared for by car dealers who have trained personnel to render this type of service, or by competent refrigeration service organizations. Future demand is estimated as high as 10 percent of total car production by one major manufacturer, while another estimates a million or more of its care will be equipped in the not too distant future.
AIRCRAFT AIR CONDITIONING
In recent years, heating, cooling and ventilating of air planes has progressed from comparatively simple systems to highly complex multi-purpose designs. The attendant control problem has become correspondingly complex. On older, non-pressurized planes, the heating system consisted either of a steam boiler and radiator or a angle stage or double stage heat exchanger. On both typos, the cabin temperature was adjusted by portioning the face and by pass dampers. While these were sometimes moved by an automatic modulating control, in the majority of cases they were positioned by one of the ship'B crew. As these planes cruised at less than 200 mph and normally operated at low altitudes, changes in outdoor- air temperatures were generally gradual enough so that manual readjustment of controls could maintain reasonably comfortable cabin con ditions. Nearly all of these heating systems were marginal in respect to heat available, and the main problem was lack of heat, rather than inadequate control.
Non-Pressurized Cabins
With the advent of the combustion type heater, and use of larger and faster planes, use of manual controls be-
Transportation Air Conditioning
685
fame impracticable. The combustion typa heaters reach full rating in less than a minute after being turned on, and as they arc rated at 100,000 Btu per hr auu up, and since several heaters are generally used, it would take full time of one crew member to keep cabin temperature regulated. As ships of this typa are not pressurized, the heating system is still comparatively simple.
In one typa, two 100,000 Btu heaters are placed in parallel positions and the ram air from an external scoop is passed through the beaters and discharged through a series of distributing outlets located in the cabin ceiling. The cabin air is discharged through grilles located in the bottom walls of the cabin. An auxiliary nose heater is used by the crew to obtain additional heat for the cockpit or for windshield de frosting.
The cabin is maintained at the desired temperature by means of an automatic control which operates both heaters simultaneously. This control-consists of two duct ther mostats, one being mounted in the air inlet duct between the air scoop and the heaters so that it is affected by outdoor ambient temparatures, and the other being mounted in the heater outlet duct so that it is affected by the discharge air temparatures. A thermostat in the cabin is so located that a continuous stream of cabin air I passes through it. This type of control has been found to respond to a 1 deg temperature change in less than a second.
As the outdoor temperature starts to drop, the outdoor air duct thermostat decreases in resistance, unbalancing an electronic bridge. This unbalance is amplified by vac uum tubes and causes a power tube to close a relay, turning on the combustion heaters. The resulting in crease in temperature is sensed by the warm air duct thermostat which increases in resistance, thus rebalancing the bridge and causing the relay to opan. If there were no loss by radiation or convection from the aircraft'cabin, these two duct thermostats would be sufficient for ad equate control. However, the cabin thermostat is given approximately 30 times more influence than the duct thermostats and so acts as the master controller, and the duct thermostats prevent overheating or underheating and keep the discharge air from alternating between extreme cold and extreme heat.
In a slightly more elaborate system, two combustion heaters supply a plenum chamber which is maintained at a constant temperature. Air from the plenum chamber is then mixed with outdoor air to maintain desired cabin tempera ture. All of the warm air is discharged into the cabin through the walls. The discharge grilles are located on the floor under seats, and a modulating-typa controller varies pro portions of heated and outdoor air necessary to maintain desired cabin temporature. The same typa of control system as previously described is used, except that an amplifier oparates a two-phase motor capable of position ing control dampers instead of oparating a relay which
would merely opan and close the fuel valve. An auxiliary duct, running from the plenum chamber, is used by the pilot as a source of windshield defrosting air.
Pressurized Cabins
With the advent of the new high-spaed pressurized transport planes, and. the addition of cabin cooling in addition to heating, the control problem becomes more complex. On all of these airplanes, the heat of compres sion from cabin supercharger must be controlled, the air
cycle or expansion turbines must be turned on and also, the heat exchanger or combustion heaters, which are used in the system when cooling is required for additional heat, must be automatically controlled.
Assuming that one of these airplanes is operating in an extremely cold climate, the sequence of operation would be as follows:
The automatic controller for the supercharged-air inter
cooler would be in full closed position, so that none of the heat
of compression would be removed, and the air would bypass
the expansion turbine and its compressor
the secondary
after-cooler. An additional automatic controller would be op
erating the combustion heater and supplying the additional
heat necessary to maintain the desired cabin temperature. If
a heat exchanger were used as a supplemental source of heat, a
modulating control operating a damper on this exchanger would
run towards full heat position.
As the airplane enters a warm climate and heat requirements drop, the combustion heater would cease operation or the heat exchanger would go to full cold position, and the miniating
control on the supercharger compressor would move towards the cold position. When the outdoor ambient temperature rises so high that cooling is desired, the cabin supercharger inter
cooler would be opened wide. If further cooling were required, the air would go into an air cycle turbine, which is modulated
to deliver the required amount of cold air to maintain a comfortable cabin temperature.
Pressure in the cabin is maintained by providing a controlled, constant rate of air flow into the cabin suf ficient to maintain ventilation, and adjusting the cabinpressure relief valve setting, by means of a cabin pressure selector, to maintain the desired cabin pressure. Limits on maximum inside to outside pressure may be of the order of 4 or 5 psi, and safety controls should be provided to prevent exceeding this limit. There is a martmnm rate at which the cabin can change to a newly selected value, this rate being in some cases also adjustable.
The requirements for controls of this nature are ex tremely rigid. It is commonplace for ships of this type to
experience changes in outdoor ambient temperatures of as much as 100 deg in a space of 5 min For this reason, speed of sensing a change and rapidity of response in the control system is essential if satisfactory control is to be accomplished. The older type thermostats cannot be used in airplanes, due to mass of the thermostat and to vibra tion experienced on all airplanes. All modern controls use some type of bridge system with temperature-sen sitive resistors as sensing elements. In some types of controls, the bridge system feeds a sensitive halnn<*>rf relay, which in turn runs a modulating motor or controls an on-off power relay. A recent sensitive and quickly responding type uses an electronic amplifier, which in turn controls a two-phase motor, or, through relays, controls a d-c motor, or merely closes and opens a power relay for on-off applications.
In addition to extreme speed and accuracy which are required of all aircraft temperature controls, they must be able to operate under great extremes of temperature, pressure and humidity, and also withstand continuous extreme vibration. Heaters should have, in addition to control from thermostats, suitable limit controls to pre vent overheating due to failure of air supply, or any other cause. Also, there should be safety devices to shut off fuel in case of flamg failure.
On the latest high speed jet airplanes, the temperature control problem is still more severe than on the latest transports; as in addition to the accuracy required, con trol response must be phenomenally fast. For example,