CHAPTER 35
1960 Guide
less than 75 percent, based on the total heating value of the gas.' These efficiencies are based upon Equation 10.
Design Considerations
Some factors important in the design of gas heaters are:
1. Proper design of the burner head, port sizes, and locations so that the Same will not lift, float, or flash back, and be ex cessively noisy in operation.
2. Proper venting of combustion chamber. 3. Protection of valve Handler to prevent excessive tempera ture rise during operation. 4. Insulation and haffling of heater to prevent overheating of walls and floor.
INSTALLATION OF SPACE HEATERS
The two most important considerations involved in the installation of a space heater are safety and chimney draft. The items of chimney details and flue connections which should have special attention are outlined in Chapter 36, Chimneys and Draft Calculations. Proper installation of re cessed gas heaters should be made according to American Standard Installation of Gas Appliances and Gas Piping (ASA Z21.30-1959). In all cases, it is recommended that installation be made in accordance with the current National Budding Code.
REFERENCES
* 1 -- B = R Testing and Rating Code for Low Pressure CastIron Heating Boilers (Institute of Boiler and Radiator Manu
facturers, June, 1958).
* Testing and rating code for boiler-burner units (Engineering Standards Part II, Mechanical Contractors Association of Amer ica, 1956).
* / = B = R Ratings for Cast-Iron Boilers (Institute of Boiler and Radiator Manufacturers, May 10, 1955).
* Net load recommendations for heating boilers {Engineering Standards Part II, Mechanical Contractors Association of Amer ica, 1956).
'Comfort Heating (American Gas Association, 1938, p. 35).
* Gravity Code and Manual for the Design and Installation of Gravity Warm Air Heating Systems (National Warm Air Heating and Air Conditioning Association, Manual No. 5, 5th ed.).
'B. A. Landry and R- A. Sherman: Development of a design of smokeless stove for bituminous coal (ASME Annual Meeting, 1948).
' American Standard Approval Requirements for Gas-Fired Room Heaters (American Standards Association, Z21.ll, 1956, with addenda Z21.11a-1957 and Z2l.llb-195S).
* American Standard Approval Requirements for Central Heating Gas Appliances Volume IV, Gravity and Pern Type Vented Recessed Heaters, (ASA Z21.13.4, 1958).
"American Standard Listing Requirements for: Automatic Pilots (Z21.20, 1951); Gas Appliance Thermostats (Z2123, 1940); Domestic Gas Appliance Pressure Regulators (Z21.18, 1956); Automatic Valves for Gas Appliances (Z21.21, 1952); .(American Standards Association).
CHAPTER 36
CHIMNEYS AND DRAFT CALCULATIONS
Draft Definitions, Theoretical Natural Draft, Factors Affecting Natural Draft, Available Draft, Required Draft; Industrial Chimneys, Available Draft far the Industrial Chimney, Determining Industrial Chimney Sizes; Residential Chimneys, Available Draft for Residential Chimneys, Chimney Sizes for Heating and Process Boilers, Short Chimneys, Deter mining Residential Chimney Sizes, Draft Requirements of Appliances, Gas Appliance Venting; Recommenda tions of the National'Bi>ard of Fire Underwriters, General Considerations
RAFT is the pressure difference associated with the
FACTORS AFFECTING NATURAL DRAFT
D movement of flue gases through a flue or chimney. Natural draft is caused and measured by the difference weight of a column of flue gas within the flue and a corre sponding column of air of equal dimension outside the flue. Natural draft is always negative and is expressed in inches of
innaAtusrainl ddicraaftet ids
in both directly
Equations 1 and 2, the theoretical proportional to the height of the flue
and is dependent upon the absolute mean temperature of the
gases within the flue. It is also directly proportional to the
density of the air outside the flue although the effect of this
water gage. When the movement of air is supplied by a fan, the draft is
factor is minor. The formulas for theoretical natural draft are based on
said to be forced or induced. When the fan is located so as to
mean or average temperature which is one half of the sum
push the flue
through the flue, the draft is forced. When
of the entering and exit temperature. Since the difference in
the fan is located so as to draw the flue gases through the
exit and entering temperatures, or the temperature gradient
flue, the draft is induced.
in the flue, is due to the escape of heat through the walls of
THEORETICAL NATURAL DRAFT
Theoretical natural draft is produced solely by the differ ence in weight of the column of flue gases within the flue and that of a corresponding column of air of equal dimensions outside the flue. In the determination of theoretical natural draft, no allowance is made for friction or other positive or negative effects. Theoretical natural draft is expressed by the following formula:
the flue and chimney, the heat transfer characteristics of the chimney construction affect draft. Heat transfer is also af fected by the rate of flow of the flue gases through the flue so that draft is also affected directly.
The flow of flue gases through the flue is retarded by fric tion which varies directly with the friction coefficient of the flue surface, and with the rate of flue-gas flow. The friction loss may be estimated by means of one of the formulas for ducts such as the Fanning equation or it may be estimated
with sufficient accuracy by the method used for air ducts. (1) (See Chapter 21.)
The height of the flue is measured from the point of en
where
D, = theoretical draft, inches of water. H * height of flue or chimney, feet. B, -- barometric pressure, inches of mercury. p, -- density of air aiO Pand 1 atmosphere pressure, pounds
per cubic foot. p = density of flue gas at O F and 1 atmosphere pressure,
pounds per cubic foot. T, temperature of air surrounding the chimney, Fahren
heit absolute. Tc ** temperature of the gases, average or effective, in the
chimney, Fahrenheit absolute.
trance of the flue gases to the top of the flue. With no wind to produce an aspirating effect and with no obstruction such as a rain cap at the top of the flue, the column of flue gases may extend upward above the top of the flue for several feet. The effect of this column may be sufficient to overcome the negative or retarding effect of friction and to cause the observed draft to exceed the theoretical draft. This added effect has been measured in some test work. A wind blowing across the top of the flue may also produce an aspirating effect sufficient to overcome the effect of friction and to cause the observed draft to exceed the theoretical. Both of these effects are transient and unreliable and should not be considered in determining the proper design of a chimney.
Theoretical natural draft may also be expressed by the following simplified formula in which it is assumed that the
AVAILABLE DRAFT
densities of the flue gas and of the air are equal at the same
The available draft produced by any chimney is equal to
temperature and pressure:
the theoretical natural draft minus the friction loss. Given
the height, the heat transfer characteristics of the chimney
construction, the entering temperature of the flue gases and
their volume, and the friction coefficient of the flue and its
where
dimensions, the available draft is readily calculable. The efficiency of a chimney is defined as the ratio of the
p = mean density of atmospheric air, pounds per cubic foot. observed draft or available draft, produced by the chimney