Document zdnnOw7nj1XzG5Ewy3yayrjX3

Solid Copper Conductor Asbestos Broid APl--7*= SOLID ALL-ASBESTOS APPARATUS CABLE (N.E.C. Type AIA) Table A, 600 Volts, Max. Operating Temp. 125C. CONSTRUCTION: Solid plain copper insulated with felted asbestos wall, with an asbestos braid overall. APPLICATION: Recommended for use whore a 125 ' C. all-asbestos construction is desired, such as rheostat grid wire. ADVANTAGES: Heat and flame resistant insulation possessing excellent aging properties. Sixe AWG 14 12 10 Bare Diameter (m.) .064 .081 .102 Nominal Thickness -- Milt Felted Wall 30 30 30 Asbestos Broid 40 40 40 Nominal Finished Diameter (in.) .21 .23 .25 Ampacity* 30 40 50 8 .128 30 6 .162 40 4 .204 40 40 .27 40 .33 45 .37 65 85 115 3 .229 40 2 .258 40 .289 60 45 .40 45 .42 45 .49 130 145 170 1/0 .325 60 2/0 .365 60 3/0 .410 60 4/0 .460 60 45 .53 45 .57 45 .61 4S .66 200 230 265 310 'Ampacity bo*edorr30C ambient at I2SC. conductor temperatures. 3 conductors in conduit, per NEC. Net Weight (Ibs/M') 35 40 55 80 115 165 200 245 315 385 475 590 735 Shipping Length/Ft. 500 C 500 C 500 C 500 C 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R RBB 02898 Felted Asbestos STRANDED ALL-ASBESTOS APPARATUS CABLE (N.E.C. Type AIA) Table R, 600 Volts, Max. Operating Temp. 125C. CONSTRUCTION: Stranded plain copper insulated with a felted asbestos wall and covered with an overall asbestos braid. APfUCAT!CN: Suitable for general purpose wiring where 600 volt, 125C. insulotion is desired. ADVANTAGES: Heat and flame resistant insulation possessing excellent aging properties. Site, AWG orMCM 14 12 10 8 6 4 Stranding 7/.0242 7/.0305 7/.0385 7/.0486 7/.0612 7/.0772 Bore Diameter (in.) .073 .092 .116 .146 .184 .232 Nominal Thickness -- Mils felted Wall 30 40 40 40 60 60 Asbestos Braid 40 40 40 40 45 45 Nomina) finished Diameter (in.) .22 .26 .28 -31 .39 .44 Ampacity* 30 40 50 65 85 115 3 7/.0867 .260 2 7/.0974 .292 1 19/.0664 .332 60 60 75 45 .46 130 45 .50 145 45 .57 170 1/0 19/.0745 .373 75 45 .61 200 2/0 19/.0835 .419 75 45 .65 230 3/0 19/.0940 .470 75 45 .70 265 4/0 19/.1055 .528 75 45 .76 310 250 37/.0822. .575 350 37/.0973 .681 400 37/. 1040 .728 500 37/. 1162 .813 90 90 90 90 45 .84 45 .95 45 99 45 1.08 335 420 450 500 'Ampacity based on 30C. ambient at t25C. conductor temperatures. 3 conductors in conduit, per NEC. Net Weight 0bs/M') 35 50 65 85 125 180 220 265 335 410 505 615 770 905 1235 1385 1710 length/ft. 500 C 500 C 500 C 500 C 500 R 500 R 500 R 500 R 500 R S00R 500 R S00R 500 R 500 R 500 R 500 R 500 R 2M-1V83 Printed in U.S.A. THE ROCKBESTOS COMPANY Division of Cerock Wire & Cable Group. Inc. New Haven. Connecticut 06504 USA RBB 02899 Flexible Stranded sm^-- - --mtst 30QWbB*3 AP3-9>79^- FLEXIBLE STRANDED ALL-ASBESTOS APPARATUS (N.E.C. Type AA) Table W, 300 Volts, Max. Operating Temp. 150 C. CONSTRUCTION: Flexible stronded bore copper, insulated with a felted asbestos wall and covered with ar. overall v/hite asbestos braid. APPLICATION: These cables have an exceptional flexibility and are recommended for high temperature i.ijjGlIotions such as motion picture projector leads. ADVANTAGES: Heat and flame resistont insulation with excellent aging properties and flexibility. * Siie AWC Stranding Bore Diameter ('") Nominal Thickness - Mils Felted Asbestos Wail Braid Nominal Finished Diameter (in.) Ampacity* Net Weight (lbs./M') 14 104/34 .077 12 259/36 .102 10 413/36 .130 30 30 30 40 ' .22 40 .25 40 .27 40 30 50 40 65 55 8 665/36 .165 6 1050/36 .205 4 1666/36 .275 2 2646/36 .350 1 3332/36 .400 30 40 40 40 60 40 .31 45 .37 45 .44 45 .51 45 .60 90 75 120 no 170 170 225 250 255 335 1/0 4214/36 .440 2/0 5292/36 .500 3/0 6713/36 .570 4/0 8512/36 .640 60 60 60 60 45 .64 45 .70 45 .78 45 .84 310 415 350 510 405 630 475 785 *8ased on single conductor in fro* air. 30C. ambient, 1 S0C. conductor temperatures. 3 conductors in conduit, per NEC. lengfh/Ft. 500C 500C 500C 500C 500 R S00R 500 R 500 R 500 R 500 R 500 R 500 R RBB 02900 MGTOI WIRES Type AVA 600 Volts AP4-6-78 Asbestos Asbestos flexible Stranded Tinned Copper Varnished Cloth Asbestos Braid FLEXIBLE STRANDED MOTOR LEAD WIRE (N.E.C. Type AVA) Table L, 600 Volts, Max. Operating Temp. 110C. CONSTRUCTION: Flexible stranded tinned copper insulated with asbestos, varnished doth and asbestos covered with on overall braid of asbestos having a boot unu moisiure-resisfant finish. APPLICATION: Table L cables ore recommended for heavy-duty industrial installations where a flexible siror'd'.'ci hiah 'emparature cable is dcr.ired. ADVANTAGES: Asbestos construction offers the ultimate in service reliability, possessing excellent resistance to ' heot, flame, corrosion and chemicals. Size. AWG orMCM Stranding Bare Diameter (in.) 14 41/.010 12 65/.010 10 104/.010 .075 .095 .120 8 133/.0111 6 133/.0140 4 I33/.0177 3 133/.0199 2 133/.0223 1 259/.0180 .162 .205 .260 .292 .327 .370 1/0 259/.0202 2/0 259/.0227 3/0 259/.0255 4/0 259/.0286 .415 .461 .526 .591 250 300 350 400 500 750 1000 427/.0242 427/.0265 427/.0286 427/.0306 427/.0342 427/.0419 427/.0484 .653 .716 .772 .826 .923 1.131 1.307 1st felted Well Nominal Thickness -- Mil* VC 2nd felted Insert Wall 10 30 15 10 30 15 10 30 15 10 30 15 15 30 20 15 30 20 15 30 20 15 30 20 20 30 30 20 30 30 20 30 30 20 30 30 20 30 30 25 40 40 25 40 40 25 40 40 25 40 40 25 40 40 30 40 40 30 40 40 Asbestos Braid 40 40 40 45 45 45 45 45 45 45 45 45 4S 45 45 45 45 45 45 45 Ampacity' 30 35 45 60 80 105 120 135 160 190 215 245 275 315 345 390 420 470 580 680 'Ampacity based on 30C ambient at 110C conductor temperatures. 3 conductors in conduit, per NEC Nominal Finished Diameter (in.) .27 .29 .31 .36 .42 .47 .51 .54 .61 .66 .71 .77 .84 .95 1.01 1.07 1.12 1.22 1.45 1.61 Net Weight (lb*./W) 43 54 72 100 142 203 244 292 376 450 563 670 827 1030 1205 1328 1506 1867 2780 3553 Standard Shipping length/ft. 500 C 500 C 500 C 500 C 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 2M-11/83 Printed m U.S.A. 'THE R0CKBEST09 COMPANY Division of CerocK Wire & Cable Group. Inc. New Haven. Connecticut 06504 USA RBB 02901 Asbestos Asbestos I 1. Flexible Stranded j Tinned Copper Varnished Cloth Heat and Moisture-- Resistant Finish "WIRE MJBCe*. . Table Mb 6QOV0H* AP5-5-78 FLEXIBLE STRANDED MINING MACHINE CABLE, AVC Table ML, 600 Volts, Max. Operating Temp. 110 C. CONSTRUCTION: Flexible stranded tinned copper insulated with asbestos, varnished cloth and asbestos covered with an overall braid of asbestos with c heat and moisture-resistant finish. APPLICATION: Cables are specifically designed for use on wiring or. heavy-duty mining equipment. ADVANTAGES: Asbestos construction offers the ultimate in service reliability, combined with excellent heat, flame and corrosion resistance. Size. AWO orMCM Stranding Bara Diomatar (in.) 1st Faited Wall Nominal Thickness -- Mils VC 2nd Faltad Insart Wall Asbastos Braid Ampacity* 14 41/.010 12 65/.010 10 104/.010 .075 .095 .120 10 10 10 40 40 40 10 35 10 35 10 35 30 35 45 8 133/.01U .162 10 40 10 35 60 6 133/.0140 .205 10 40 10 35 80 4 133/.0177 .260 10 40 10 35 105 3 133/.0199 .292 10 40 10 35 120 2 133/.0223 .327 10 40 10 35 135 1 259/.0180 .370 15 40 15 45 160 1/0 259/.0202 .415 2/0 259/.0227 .467 3/0 259/.0255 .526 4/0 259/.0286 .591 15 15 15 15 40 40 40 40 15 45 190 15 45 215 15 45 245 15 45 275 250 427/.0242 .653 20 40 40 45 315 300 427/.0265 .716 20 40 40 45 345 350 427/.0286 .772 20 40 40 45 390 400 427/.0306 .826 20 40 40 45 420 500 427/.0342 .923 20 40 40 45 470 `Ampacity based on 30C ambient of I iOC conductor temperatures. 3 conductors in conduit, par NEC Nominal Finishod Diomatar (in.) .27 .29 .31 .36 .40 .45 .49 .52 .59 .64 .69 .75 .82 .94 1.00 1.06 1.11 1.21 Nat Weight (Ibs./M') 44 55 72 100 137 194 237 277 363 440 535 658 811 985 1195 1370 1545 1895 Standord Shipping langth/Ft. 500 C 500 C 500 C 500 C 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R 500 R RBB 02902 600 Volts AP6-5-78 HYPALON** CLASS 130 MOTOR LEAD WIRE 600 Volts, Max. Operating Temp. 130 C. CONSTRUCTION: Flexible stranded tinned copper. Hypalon" insulation. APPLICATION: Class 130 motor lead wire. ADVANTAGES: Small diameter flexible, obrasion resistant lead wire for Class 130 motors. Sixe | *.WC Diometer Insulation Tt\i A 14 41 /.010 12 65/.010 10 104/.010 .075 .095 .120 .047 .047 .047 40 50 70 8 133/.0T 11 .167 6 133/0140 .210 4 133/.0177 .266 .063 .063 .063 90 125 170 3 133/.0199 .299 2 133/.0223 .335 1 259/.0180 .378 .063 .063 .078 195 225 265 1/0 2/0 3/0 4/0 259/.0202 259/.0227 259/.0255 259/.0286 .424 .477 .536 .601 .078 .078 .078 .078 305 355 410 475 'Ampacity dosed on single conductor m free air. 30C. ombiem. 130C. conductor temperatures. Overall Diameter (in.) Net .18 30 .20 37 .22 52 .30 .35 .40 .44 .47 .55 84 134 182 222 270 344 .59 429 .65 544 .71 658 .77 795 "Reg. trod# mork OyPont. 2M-11/83 Printed in U.S.A. THE ROCKBE9TOS COMPANY Division of Cerock Wire & Cable Group. Inc. New Haven. Connecticut 06504 USA RBB 02903