Document zdn4QbNjbzjLdgLR5zmJVVwrR

Industrial Hygiene Digest June. 196) 594 On the Probletft of Air Pollution by Maleic Anhydride. K. V. Grigor'eva. Gigiena i Sanit. 29, 8-12 (March, 19^4). Russian. Investigation* were earned out m the vicinity of industrial plants producing phthalic anhydride, where the wastes discharged into the air contained maleic anhydride. This latter compound was detected in the air at a distance Of 500 m. from the site of discharge in con centrations of 0.0 to 3. 3 mg./cu.m. , and within a radius of 1 km. in concentrations of 0 0 to 2.6 mg. /cu.m. Work is being continued to obtain hygienic backgrounds for determining the maximum permissible concentration of maleic anhydride in the atmospheric air. Its olfactory threshold value and that for producing an irritating effect on the mucous membranes of the eyes and respiratory tract have already been determined . For most sensitive persais these threshold values have been placed at 1.3 mg. /cu. m. and 1.0 mg. /cu. m. of maleic' anhydride, respectively. .. APCA Absts . PREVENTIVE ENGINEERING 595 Trade Association Activities Toward Noise Standards. R.H. Bohman. ASHRAE J. 6, 63-ii (June, 1964). The current and anticipated activity by various manufacturers' trade associations in the field of sound, its measurement, rating and control is discussed. The paper includes a summary of noise investigation using test procedures of the Air-Conditioning Refrigeration Institute model municipal ordinance. - - J. Am. Soc. Safety Eng. Absts. 596 The Light Fantastic: Lasers. Haaards, Controls. R.C. Starr. Safety Standards 14, i-ll, 21 (May-June, 19651. Effective measures for controlling the haaards of lasers or masers and their associated equipment involve principles and techniques that are well known among safety engineers and industrial hygienists. Specific control suggestions include: All work with lasers should be isolated as far as practicable from other work areas and employee traffic routes, and preferably housed in a fully enclosed space with adequate mechanical ventilation. Room lighting should be maintained at adequate levels (to prevent excessive e-.e dilation, increasing the chance of accidental retinal exposure to the laser). The area s.nould be tree of reflective surfaces whicr. could bounce the beam into a person's eyeslchief suspects include doorknobs: desk, table, and counter tops: metal or glass containers: walls: cabmeti. even personal jewelry). The room or area in which a laser is used should be regardeo as a controlled area with aeces* limited to those whose work requires it; this should be indicated bv appropriate signs at each door to the room Within the controlled area, an audible or visual s:gr.. sr.o.ic be associated with the charging oi the laser condenser to indicate that the laser is aoo^: :: zt f.asned or is running continuously Signals should be such that they will not cause a person :o look in the direction of the laser, but rather away from it. Equipment operating at upware of 15.30C volts should be monitored for possible x-radiation. Cryogens, such as liquefied r.itroger. and nelium used (or cooling laser equipment, demand personal protection-hands, face, and oodv --for all who handle tnerr. Stand* electrical safety specifications and practices presenaed for nigh-voltage equipment :r. genera, are applicable to laser power sources. Capacitors mould be discharged before cleaning or repair work is undertaken: since they can retain a cnarge even when the power is disconnected. bleeder resistors should be provided and left in tne circuit until the laser is used again 01 132 2677 11