Document zdj69XxKm9zKXmMLaa0L0gzE3
Copyright i960
BY THE
American Society of heating, Refrigerating
and
Air-Conditioning Engineers, Inc.
and by it
Dedicated To the Advancement of
The profession
and
Its Allied Industries
TEXT' AND ILLUSTRATIONS ARE FULLY PRO TECTED BY.'CaRVRIGHT; ANbl.NOTHING THAT APPEARS MAY-BE REPRINTED'EITHER WHOLLY OR IN PART fWITHOUT'SPECIAL PERMISSION.
Printed and Bound by Waverlt Press, Inc. BALTIMORE MARYLAND
PREFACE TO THE 38th EDITION
The Heating Ventilating Air Conditioning Guide, U-Values for building constructions which include high-
1960 contains a Technical Data Section of 792 pages and conductivity members.
therefore, is the largest in a series which has now reached 38
Chapter It--Heating Load. Temperature design data were
editions. The increase in new technical text is considerably added for 9 cities in Alaska as prepared from U. S. Weather
greater than the 24 pages added because space for new text Bureau records.
was obtained in many places throughout the book by con
Chapter 14--Radiators, Convectors, Baseboard and Pinned-
densation and revision of previous text.
Tube Units. Rating method information was brought into
The previous grouping of chapters in twelve sections has conformity with latest standards used by manufacturers.
been retained as follows: I--Fundamentals, II--Environ
Chapter 17--Electric Heating. Several sections referring to
ment, Comfort, and Physiological Principles, III--Heating use of electric beaters were revised.
and Cooling Loads, IV--Room Heating and Cooling Meth
Chapter 18--Warm Air Heating Systems. The entire chap
ods and Equipment, V--Air Systems and Equipment, VI-- ter was reviewed to permit changes in application resulting
Steam and Water Systems and Equipment, VII--Heat Gen from NWAHAACA experience. New diagrams were added
erating Methods and Equipment, VIII--Refrigeration, to show duct length equivalent of fittings aod intakes. Pre
Spray Apparatus, and Sorbents, IX--Controls, Instru- - cautions for starting up perimeter systems were added.
ments, and Motors, X--Specific Applications, XI--Indus
Chapter 19--Central Systems for Air Conditioning. The
trial Systems, and XII--General.
section on Zoning and Zone Control was rewritten. Dia
Some of the outstanding improvements to be found in this grams and text for high-pressure systems as well as for the
edition include (1) a rewritten chapter on thermodynamics dual-duct systems were improved.
to facilitate explanation and solution of problems dealing
Chapter 85--Sound Control. As a result of a critical review
with control of environment in occupied spaces, (2) exten by the Society's Research Advisory Committee on Sound
sive revision of text and improvement of illustrations io the Control this chapter was revised extensively and eight illus
chapter on sound control, (3) new data od restaurant hot trations were improved.
water requirements and method of rising storage tanks,
Chapter 86--Steam Healing Systems. Eight illustrations
coils, and heaters, (4) a new section dealing with funda were improved as a result of review by the Research Ad
mentals, detection, and elimination of odors, (5) extension visory Committee on Hot Water and Steam Heating and
of winter design temperatures to 9 Alaskan cities, (6) new others. Precautions were added with regard to piping for
data on equivalent duct lengths for sheet metal fittings,.(7) blast heaters.
additional information on heat gain of insulated-cold pipe
Chapter SI--Pipe, Fittings, Welding. Some extensions were
and on loss from tarnished copper tube, (8) a new chart and made in the table on applications of pipe, tube, and fittings.
table for selection of chimney sizes for automatically fired
Chapter 39--Industrial Insulation. Revised tables were
boilers, (9) revised data on treatment of water for preven provided to show heat gain of insulated cold pipe and also
tion of corrosion and scale, (10) maximum allowable con beat loss of.tarnished copper tube.
centration of air contaminants adjusted to values adopted
Chapter SS--Fuels and Combustion. A new table was added
by the ACGIH in 1959, (11) many new illustrations of auto to Bhow'characteristics of natural gas distributed in various
matic control arrangements for air-conditiooing systems, large cities. The text dealing with gaseous fuels was brought
(12) a rewritten chapter on residential air conditioning, (13) up to date.
rating data for steel boilers, packaged units, and furnaces
Chapter S4--Automatic Fuel-Burning Equipment. A new
revised to meet recent changes in rating methods, (14) new section on operating controls for commercial and industrial
data on operating controls for oil burners, and (15) a new as well as domestic oil burners was provided. Flow capaci
table of flow capacities of gas piping.
ties of gas piping are shown in a new table. Extensive revi
The significant changes in the various chapters are as sions were made in the text.
follows:
Chapter 85--Heating Boilers, Furnaces, Space Healers.
Chapter 8--Thermodynamics. The text was rewritten to Most recent methods of rating boilers and packaged units by
improve the presentation for students of air conditioning SBI, IBR, and ABAI standards were inserted together with
and to facilitate solution of problems dealing with control tabulated ratings. Suggestions were improved for cleaning,
of environmental conditions by means of circulated treated and maintenance of boilers and systems. The portion of the
air. Many new illustrations and new problems were added. chapter dealing with warm air furnaces was rewritten with
The Goff and Gratcb tables on thermodynamic properties of new discussion of ratings, heat exchangers, equipment, com
moist air and those on water were retained with the same ponents, and controls.
completeness as in the previous edition.
Chapter 86--Chimneys and Draft Calculations. A new chart
Chapter 7--Air Contaminants. The tables of maximum al and table were added for selection of chimney size for auto
lowable contaminants were brought up to date with the 1959 matically fired, intermittently operated heating and process
recommendations of the American Conference of Govern boilers. A section on gas appliance venting was added to
mental Industrial Hygienists. A new enlarged section od bring information in agreement with latest practice of
odors and odor control was added.
GAMA and NFPA.
Chapter 9--Heat Transmission Coefficients of Building Ma
Chapter 88--Refrigeration. A section was added on control
terials. A new method was presented for calculating overall of absorption refrigeration systems.