Document zda99Rry3a7dv4emkV2OzVz9m

1140 CHAPTER 45 .1958 Guide w A Study of Dust Control Methods in an Asbestos Fabricating.Plant, by R. T. Page and J. J. Bloom field (U. S. Public Health Reports, Reprint No. 1583, Nov. 28, 1537). } " Rules Relating to the Control of Silica Dust in Stone Crushing Operations (New Tori State Depart, ment of Labor, Industrial Code.Rule.No.;34, July, 1942): u Design of Exhaust Systems, by J. M. Kane (Heating and Ventilating, November 1945, p. 68). ` Foundry Ventilation, by J. M.'Kane (The Foundry, February and March, 1946). ' n Pottery Dusts: Their Collection and Removal, by W. M. Oddie (Pottery Gazette, Vol. 63, 1928, p. 1280). ' a Scrapbook of Exhaust Hoods, by J. M. Kane (Heating and Ventilating. Portable Grinding--July 1950; Grinding Polishing, Buffing--August 1950: Foundry Shakeout--November 1950; Melting Furnaces--Febniary 1951; Pottery--March 1951; Mixers--April 1951; and Woodworking-^June 1951). " ' Design of Exhaust Ventilation for Solid Material Handling, by R. T. Prihg et al (Industrial and Engi neering Chemistry, November 1949).. - * ` h HartzeU Blowers: Engineering Data A Installation (Hartzell Propeller Fan Company, Bulletin 1001). ,** The Application of Local Exhaust Ventilation to Electric Melting Furances, by J. M. Kane {Transac tions, American Foundrymen's Association, Vol.`52, 1945; p. 1351). J - * Control of Silicosis Hazard in the Hard Rock' Industries. II. An Investigation of the Kelley Dust Trap for Use with Pneumatic Rock Drills of the Jackhammer Type, by T. Hatch et al (Journal of Industrial Hy giene. February 1932, p. 69). n Modified Design of Hay Dust Trap, by P. S. Hay (Journal of Industrial Hygiene,January 1930, p. 28). ' American Standard for Grinding, Polishing and Buffing Equipment Sanitation (American Standards Association, Z 43^1941). . 1 .y-. Swing Frame Grinder Dust Control, by J. M. Kane (The Foundry, August 1944).* \ <o Design of Kitchen Range Hoods, by J. M. Dalla Valle (Heating and Ventilating, August 1953, p. 95). si What We Make (B. F. Sturtevant Co., Catalog.No. 500). e Ventilation of Motion Picture Booths, by P. Drinker and J. R. Snell (Journal of Industrial Hygiene and Toxicology, April 1938, p. 321). u How to Justify an Industrial Air Conditioning Investment, by P. J. Marschall (Heating, Piping and Air Conditioning,February 1952,- p.-71).-;; ` u How to Design Exhaust Hoods for Quarto-Fusing Operations, by E.- C. Riley et al (Heating and Ven tilating, April 1940,, p. 23). ... , .^ ** A Study of Quarto-Fusing Operations with Reference to Measurement and Control of Silica Fume by E.1 C. Riley and J. M. DallaValle (U. S. Public Health Reports, Vol. 54, 1939, p. 632). : _ u Ventilation of Open Tanks, by A. C. Stem (American Industrial Hygiene Association, Industrial Hy giene Quarterly, Sept. 1950). _ ' `v Tabulation of Atmospheric Contaminants Released by Open Surface Tanka, by Irving Kingsley (New York State Department of Labor,.Division of Indttstrial Hygiene-, Engineering Unit Plates 161, 162, 163). a Chlorinated Solvent Exposures at Degreasing Operations, by K. M. Moree and L. Goldberg (Industrial Medicine, October 1943, p. 706). Ventilation of a Trichlorethylene Degreaser, by W. N. Witheridge and H. T. Walworth (Journal of Industrial Hygiene and Toxicology, May 1940, p. 175). . 4a American Standard for Safety in Electric and Gas Welding and Cutting Operations (American Stand ards Association, Z 49.1). .. ' ` .. . Rules Relating to the Removal of Dust, Gases, and Fumes (New York State Department of Labor, in dustrial Code Rule No. IS, Jan. 1931). a Air Flow in' Free Convection Over Heated Bodies, by T. F. Hatch and JD. Barron-Oornxco (ASHAE Journal Section, Heating Piping and Air Conditioning, October 1956, p. 117). Energy Losses at Suction Hoods, by A. D. Brandt and R. J. Steffy (A.S.H.V.E. Transactions, VoL 52, 1946, p. 205). 4 Resistance Test on Pipe, by A. Nutting (Mechanical Engineering, May 1938). Design of Injectorfor Low Pressure Air Flow,' by G. E. McElroy (U. S. Bureau of Mines, Technical Pa- V American Standard Safety Code for Ventilation and Operation of Open Surface Tanks (American Stand ards Association, Z 9.1-1951). , CHAPTER 46 PROCESS AND PRODUCT AIR CONDITIONING i General Requirements for Manufacture, Processing and Preservation; Design Con ditions and Application Data; Classification of Problems; Moisture Content and Regain; Conditioning and Drying; Chemical and Biochemical Reactions; Crystallization; Control for Machining. Polishing, and for Static Elec tricity Elimination; Laboratory Conditions; Calculations PROCESS and product air conditioning is concerned with the design and application of equipment for obtaining proper conditions for the manufacturing, processing, and preserving of material, equipment, and commodities. This chapter includes a general discussion of these conditions and also a comprehensive list of specific requirements for various types of products.: GENERAL REQUIREMENTS FOR MANUFACTURE, PROCESSING AND PRESERVATION In order to apply air conditioning to 'industrial processes, the air coridi-.. tioning engineer must have a thorough understanding of the processing problems involved. Individual processes and machines are changing rap idly, and air conditions must be revised constantly to meet the new conditions. Table 1 lists the temperatures and relative humidities required for storage of certain commodities, and for manufacturing and processing of *'"6rs. In some cases the temperatures and relative humidities listed TMa^e. * kave no direct influence upon the product itself, but do affect the efficiency of employees, and in turn affect workmanship, uniformity and the cost of production. Sometimes, a compromise between the known optimum condition for processing and that required for worker comfort is unavoidable. , ,, JVr conditioning for industrial processes is so extensive and involved that a detailed treatment is beyond the scope of this chapter. It is possible to cover only a few salient points of the general subject. In many in- ustries the exact conditions to be maintained are determined and known only by the manufacturer who specifies them. In' other industries there s a wide variance between manufacturers' requirements, depending on esults desired, experience, and cost considerations. In general, any industrial air conditioning problem in processing may classified under one or more of the following: Control of regain. t-ontrol of rate of chemical reactions. 4 r,01, f rate of biochemical reactions. 5 Co t ' ra*e crystallization. g' p :roJ f temperature for close tolerance machining and grinding. 7 , , dew-point for protection of highly polished surfaces. 8; , humidity for static electricity elimination, ntrol of conditions for material test laboratories. 1141