Document zd9rV1pdyQVKkBqy4kb511d4z
Air Conditioning, Automatic Heating Systems
Gar Wood Industries, Inc.
AIR CONDITIONING DIVISION
7924 Riopelle Street QaftUxxt Detroit, Mich.
Licensed Distributors in All Principal Cities
TEMPERED-AIRE UNIT
Tempered-Alre heating and air
conditioning equipment includes fil ters, blower, humidifier, furnace (with "Economizer") and integral oil burner of pressure atomizing type. Cloth filters can be easily laundered. All
units can be equipped with a water heating coil for use in winter. The installation of. an auxiliary duct for
intake of outside and basement air in summer is desirable. Air can then be drawn from the basement during the day and from the outside at night to provide ventilation and cooling during warm weather. Change from basement air to night air may be manually or automatically controlled.
Ratings and Dimensions
No. I02-A No. 102
No. 103 . No. 104
No. 105 No. 105-C
Btu 1 Hour at Bonnet..................... Btu 1 Hour at Grilles....................... Air Delivery, CFM..........................
Heating Surface, Firebox, Sq Ft.... Heating Surface. Economizer, Sq Ft. Total Heating Surface...................... Fitter Area Sq.Ft.............................. Motor Horse Power--Burner........
Motor Horse Power--Blower.......... Current Consumotion--Burner
Current Consumption--Blower___ Overall Length, inches...................
Overall Width. Inches......................
120,000 100,000 1000 to 1575
30
60 90 24 1/6
1/4 MOW
250W 92%
38%
120,000
100,000 1000 to 1575
30 60
90 34
1/6 1/4 250W 250W 96%
40
165.000 135.000 1375 to 2150
33
99
132 43 1/6
1/3 250W
330W 117i%
40
225.000 185.000
1875 to 2950 44 132 176
60 1/6
1/2 250W 500W 140%
40
300.000 245.000
2500 to 3925 55
165 220
77 1/4 3/4 325W
750W
156% 40
400,000
3000 to 4500 55 165 220 77 1/4 1
325W . 1000W 156%
40
CONVERSION OIL BURNERS--
Provide automatic oil burning equipment
for coal-fired heat
ing plants. Pres
sure atomizing
type, handle
heavy, low grade
fuel oil. Sturdy,
noiseless, easily
accessible. Fit
any furnace or boiler regardless
of shape.
Model "W" 412-2500 sq. ft. net
steam radiation.
Model "K'* 412-2400 sq. ft. net
steam radiation.
Model "H" Up to 625 sq. ft. net
steam radiation.
MODEL "0" AUTOMATIC OILFIRED WATER HEATER--Provides quick, convenient, inexpensive and un
limited supply of domestic hot water for industrial and commercial buildings. Com plete, quiet. Bums low-priced No. 3 fuel oil.
Capacities and Dimensions
Two sizes, 200 and 300 gal ca pacity. 100 F rise per hour.
Overall height 48 in.
Overall width 28Ji in.
Length 49 in. and 61 in. re spectively.
858
Gar Wood Industries, Inc. Air Conditioning, Automatic Heating Systems
MODEL "R" BOILER-BURNER UNIT
A compact, fire-tubular steam or hot water heating boiler, with an integral oil burner.
Boiler built of heavy rust-resisting boiler plate, electric ally welded. The combustion chamber walls are carried clear to the crown sheet. The result is a considerably higher temperature of fire than is found in the conventional boiler, and better combustion of No. 3 oil.
Since there are no water legs, the bulk of the heating surface is concentrated in the firetubes, or secondary heating surface, resulting in maximum extraction of heat from the hot gas which leaves the firebox and consequent low stack temperature, high efficiency and operating economy.
Ratings and Dimensions Maximum Net Steam Load, Sq Ft........................ Maximum Net Hot Water Load, Sq Ft................ Maximum Gross Steam Load, Sq Ft..................... Maximum Gross Hot Water Load, Sq Ft............. Heating Surface. Sq Ft........................................... Overall Width. Inches............................................. Overall Length. Inches............................................
R475 475 760 712 1140 52 3036 53
R750 750 1200 1125 1800'. 68 3036 65
RIOOO 1000
. 1600 1500 2400 84 37`% 59%
INDIRECT AIR CONDITIONING CABINET
-Combined with "R" boilers, it provides heating, ' humidifying, filtering and circulation of air.
The air drawn by blower is first cleaned by dry cloth filters, then forced through the humidifying chamber, where proper amount of healthful moisture is added by passing through a warm vapor mist, regulated by a room humidistat. The air is then warmed to correct tempera ture by passage through the copper blast heater. Standard units, in capacities from--
111,000--497,000 Btu Hour at bonnet 89,000--397,000 Btu Hour at grilles
R1400 1400 2240 2100 3360 118 37>% 66
R1800 1800 2880 2700 4320 154 37% 80
GAS-FIRED TEMPERED-AIRE
RATINGS AND DIMENSIONS
No. 90
AGA Input, Btu per hour............ 135.000
AGA Output, Btu per hour.......... 101,250
Grille Delivery Btu per hour........ 90.000
900-1425
34
Blower Motor Size........................ % Hp
Blower Motor Current Consump. 250 Watts
96%
Overall Width. Inches...................
40
No. 120
180,000 135.000 120.000 1200-1900
34 1/4 hp 250 Watts 96% 40
Built in a single compact unit it accom plishes the various functions of air con ditioning in an efficient manner. Filtering, ventilating, humidifying and cooling in summer functions are similar to' the oilfired Tempered-Aire.
Heating is automatic, clean and odorless. The gas valve is controlled by a thermostat. The furnace is made of heavy gage copper bearing steel welded into a single unit. Corrugations and ribbings give the heating surface more than double the area of a flat surface of equal outside dimensions.
859