Document zd8bVRVvvdGXyDgGNbJ9VE2ga

Inter ONteo Paraonnal and Organization Staff April 8, 1981 Mr. R* P. Doherty Manufacturing Mana^jy Sheldon Road Plant 00 V. 0. Atkina J. E. Fisher V. Q. MoQruther J. E. Tennant Subjects Airborne Asbestos Monitoring - Sheldon Road Plant Aa requested by Manufacturing Staff, airborne asbestos monitoring vaa con ducted at the Sheldon Road Flant on March 6, 198l to determine if residual con centrations of asbestos are preaent in plant air in areaa that formerly used asbestos in heater housing manufacture. Air samples vers taken in the former mix room and former molding and deflashing areas. In addition to the air samples, settled duet sampled vere gathered in the mix room. The former molding and deflashing area is nov the Injection Molding Department (Dept. No. 8610) end the former mix room is nov the Maintenance Fabrication Department (Dept. No. 6430). All of the equipment used in the molding and de flashing of the asbestos reinforoed heater houeing has been removed. The mixers end extruders ueed in the mix room have been removed, but the asbestos storage silos remain. The statement vas made by supervision of the Maintenance Fabrication Department that aebeetoa is etill in the eiloe. The first floor utility entrance to the eiloe are not sealed and are being used for storage. The permissible occupational exposure limit (PEL) for asbestos is 2.0 f/cc and the medical monitoring aotion level ie 0.1 f/co. As can be seen from a review of the attached data, all of tha results of air Bamplsa taken vere significantly below the PEL and aotion level. Four settled dust samples vere obtained in the former mix room. The samples vere analyzed by the Ford Industrial Hygiene Laboratory using a quick screening test for aBboBtoa developed by the National Institute for Occupational Safety and Health (NIOSH). The samples taken from one of the supply air ducts and the upper sill of one of the materials elevators vere positive for asbestos. Of particular concern is the sample from the supply air duct, because eeveral inches of dust vas observed in the bottom of the duct directly below the air register. The supply air system, which is also part of the heating system, vas not operating on the day of our visit, but ve understand it ia an active system. It is probable that vben the supply air system ie operational airborne asbestos concentrations approaching the medioal monitoring aotion level may be detected. Wasort on the positive identification of asbestos in the supply air ducts and in the settled dust collected on the materials elevator, it is recommended that: 8006 1828 PRODUCED BY FORD SCF-FORD-3086 MX*. R. P. Doherty -2- April 8, 1981 3.) The exterior end interior of supply air duots located on both floors of the former six room be cleaned ueing vacuum cleaners approved for asbestos clean-up and after vacuuming be washed down with water. Special attention must be given to areas where dust may have accumulated, euoh as elbows, traps, and points farthest from the fan station. ' 2) After the supply air ducts are cleaned, the fixtures, walls and ceiling of the former mix room be cleaned. 3) Asbestos warning signs be posted during the clean-up operation per OSHA 1910.1001 paragraph g, page 5^9 U) Approved respiratory protective equipment (Industrial Relations Bulletin No. 15) be worn by all employes engaged in the clean-up operation. 5) Special clothing including coveralls, headooverings, gloves, and foot coverings, per OSHA 1910.1001 paragraph 3, page 5*+7 be worn by all employes engaged in the clean-up operation. Employes must also be pro vided with a restricted area to change out of the special olothing and shower. Further the contaminated olothing must be laundered or disposed of according to the provisions of OSHA 1910.1001 paragraphs b and o, page 5^8. 6) Employes involved in the clean-up operation should be included in the medical monitoring program being conducted by the plant for employes who were ex posed to asbestos during the production of asbestos reinforced heater housings. 7) The first floor entrances to the silos should be permanently sealed and plans made to dispose of the asbestos remaining in the silos in the near future. Further, until, tha asbestos is disposed warning signs as specified in recomiiiondatiou No. 2 must be posted. AttotiiMontu H. B. Lick Senior Industrial Hygienist Industrial Hygiene and Toxicology Dept. Employe Health Services 8006 1829 PRODUCED BY FORD INDUSTRIAL hygiene services section INDUSTRIAL HYGIENE AND TOXICOLOGY DEPARTMENT EMPLOYE HEALTH SERVICES SHELDON ROAD PLANT Departments 8430 and 8610 March 6. 1981 PERMISSIBLE occupational exposure limits for airborne contaminants Contaminant Permissible Exposure Limit in f/cc* ' Asbestos 2.0 *f/ce = fibers of asbestos per cubic centimeter of air RESULTS Location/Conditicns Airborne Asbestos Concentration in f/cc Dept. 8430 - Maintenance Fabrication (Former Asbestos Mix Room) General Area Air Sample, 1st floor at D-9 end of room General Area Air Sample, 1st floor at D-ll end of room General Area Air Sample, 2nd floor at D-9 end of room General Area Air Sample, 2nd floor at D-ll end of room 0.008 0.009 0.008 0.008 Dept. 8610 - Injection Molding (Former Molding and Deflashing Dept) General Area Air Sample at oolumn D-ll General. Area Air Sample at oolumn F-10 General Area Air Sample at oolumn E-l4 General Area Air Sample at column H-ll 0,009 0.007 0.009 0 009 DATA RETRIEVAL NUMBERS3 HBL 1198 - 1205 INSTRUMENTATION AND ANALYSIS! Bendix BDX pumps with Milipore Type AA 0.8 u mem brane filters* Fibers counted using 430X Phase Contrast Microscopy. ANALYST!! L. Latorro, Senior Industrial Hygienist aoo6 isso PRODUCED BY FORD INDUSTRIAL HYGIENE SERVICES SECTION industrial hygiene and toxicology department -- EMPLOYE HEALTH SERVICES SHELDON ROAD PLANT _ March 6. 1981 Settled Duet Sample Screening for Asbestos Location Floor of alio 6092 Upper sill, of elevator 6051A. Supply aiv duct, 2nd floor of former mix room Stairway to 2nd floor of mix room at D-9 end DATA RETRIEVAL NUMBERS? HBL 1206-1209 ANALYSISi N10SH Quick Screening Teat for Asbestos ANALYST^ I.. Latorre, Senior Induatrial Hygieniat Results Negative Poaitive Poaitive Negative 6006 1831 PRODUCED BY FORD