Document zd06xEVxa4Xk0gY8kJvV32pe7
ABDOO127261
Pollutant
Particulate Matter S02 NOx
CO VOC TRS LEAD CFCs/HCFCs Other Total HAP's (VOC) Total HAP's (Non-VOC)
1998 Air Emission Calculations
for the Annual Emissions Report
Allowable Rate Tons per Year
198.59 5.36 198.72
147.09 190.01
0 0.56
0 0 143.55 7.74
Actual Emission
Tons per Year
83.75 0.37 83.41
20.70 50.87
0 0 0 0 7.40 2.59
1998 Natural Gas Usage (MMBTU) =
1217685 MMBTU
TSP/PM10 Calculation
AP-42 factor =
0.005 Ib/MMBTU
3.04 TPY
From Fluid Bed & Rotary Dryers
Stack test (#/hr) =
7.53
(Based on 7/98 Stack testing) = 32.98 TPY
From Cyclone Dryer #10 Stack test (#/hr) =
9.3
(Based on 7/98 Stack testing) = 40.73|TPY
From Cyclone Dryer #11 Stack test (#/hr) =
6.34
From Vinyl Silos Stack test (#/hr) =
0.608
From cmpd silos Stack test (#/hr) =
0.90
(Based on 7/98 Stack testing) -- 27.77] TPY
(Based on 7/98 Stack testing) = 2.66 TPY
(Based on 7/98 Stack testing) - 3.94 TPY
Total =
.ft. f/i
TPY
ABDOO127262
S02 Calculation
AP-42 factor = TPY
0.0006 Ib/MMBTU
NOx Calculation
AP-42 factor = .83.4iaa! TPY
0.137 Ib/MMBTU
CO Calculation
AP-42 factor = TPY
0.034 Ib/MMBTU
1998 Natural Gas Usage = VOC Calculation
1217685 MMBTU
AP-42 factor = 0.0057 Ib/MMBTU
3.41
TPY
Total VOC from Plasticizer =
40.00
TPY (Permitted Total)
Fugative VCM -
2.40 TPY (Obtained from Environmental Coordinator)
VCM Stack Emissions =
4.74
TPY
(EPA Method 107)
Total VCM Emissions =
7.14
TPY
Fugative Methanol Stack Emissions =
0.26
TPY
Total VOC Emissions =
50.87
TPY
Total HAP's (VOC) =
7.40
TPY
ABDOO127263
Total HAP's (Non-VOC) Lead Calculation Total Lead Emissions = HCI Calculation Total HCI Emissions = Chlorine Calculation Total Chlorine Emissions =
Total HAP's (Non-VOC) Emitted -
0.004
TPY
0.44 TPY
2.15 TPY 2.59 TPY