Document zbzbXkO0NyqRn91QYzg1x8Nbm
VN(2)/229
17th March, 1950
J.'/l. Roberts Limited "Limpet" Asbestos Spray Machines
The object of this series of du3t estimations was to determine
the health hazard arising from the use of the asbestos cement 3pray
and to estimate the improvement obtained by the present modifications
introduced by the firm.
The work was carried out on the 4th of October, 1949.
A room, in which no other process except the spraying of asbestos was carried out, was put at our disposal. This resulted in very clean slides from the thermal precipitator, only particles of asbestos and cement were obtained on the samples.
The same area of ceiling was sprayed for each sample in the
series. The operator stood on a working platform supported by trestles.
For each run the sampling head of one thermal precipitator was strapped
on the chest of the man operating the spray gun. For. each run except
one a sample was taken at floor'level just below the working platform
in order to get an idea of the-'risk to which other workers in the
vicinity might be exposed. In' the;case of sample TP 102/744 the second
sampling head was strapped on the chest.of the man who fed the dry
asbestos to the pre-damping machine and'then fed the opening machine.
: Of ...
Each sample was incinerated for half an hour.before counting in
order to destroy any carbonaceous dust which'might have been present.
The sample was then counted on- the Vickers projection microscope using
a 2 mm. apo. objective/and. xlO"compensating eye piece. Each sample
showed a low concentration'of asbestos fibre relative to the amount of
cement dust. The asbegtos. fibres could readily be distinguished from
the cement dust, and in the stable of results attached, the count of
asbestos fibres in particles per'cubic centimeter is given separately
from the particles of cement per cubii centimet'er. ..A photograph of a
typical sample is attached, this illustrates^hhe low'proportion of
fibrous asbestos particles.
Three main sets of conditions were tested:
1. The spraying of (dry asbestos cement. In this case the asbestos cement was opened by brushes and spiked roller in an opening machine and fed by compressed air to the gun. Round the circumference of the gun were four water sprays which impinged with the asbestos cement on the area of ceiling sprayed by asbestos.
2. The spraying of asbestos cement fed dry to the opening madhine . but damped during opening. In this case five sprays of water
were applied to the asbestos"cement in the opening machine itself. This damped asbestos cement was fed to the gun and the four water sprays applied from the circumference as under (1).
3. Pre-damped asbestos was fed to the opening machine. The asbestos mixture was fed into a horizontal drum which was rotated and the asbestos was damped during rotation. This predamped asbestos was then fed into the opening machine and thence to the gun provided with four-spray nozzles.
,/^002-77
-2-
RE5ULT3
1. Spraying dry asbestos cement
Sample No.
Position
Dust Count
Asbestos Cement Alter Incineration
at 500C.
TP.101/745 On Chest of man operating spray
483
11,866.
TP.102/746 On Floor below scaffold
234
3,324
TP.101/747 On chest of man .. operating spray >- .364
6,602
Repeat of 101/745'?
.
after cleaning room yy . `''J/* { '
with fans,
r'ty `"-V
'
Median Site
Asbestos 3.3/vi Cement 0.57/u. Asbestos 4.0/u Cement 0.64/u Asbestos 4i0/u Cement 0.56/u
. ' .
flit-:
2. Spraying asbestos cement damped during opening
Sample iJo.
//' ' ..
Position
\
,v Dust Count
Median Size
.
v5 ->/ . .
. Asbestos Cement
' ' Alter Incineration
- . at 500UC.
TP. 101/739 On chest of man operating spray
an 7
2,489
Asbestos 3.2/i Cement 0.6/u
TP.102/740 On floor below scaffold
102
2,330
Asbestos 4.O/1 Cement 0.7/u
TP. 101/741
Repeat of 101/739 after clearing air for
10 minutes with
fan
123
3,464
Asbestos 3.2/Cement1' 0.7/u
TP.102/742 Repeat of TP.102/740
Asbestos 3.0/
264
3,453
Cement 0.8/u
3.
Sorav ing with asbestos predamoed in thet drum '
:
before feeding to the opening machine
Sample Mo.
Position
Dust Count
Median Siae
Asbestos Cement After Incineration
at 500C.
TP.101/743 On chest of man operating spray
49
1,085
Asbestos 4.0/ Cement 0.6/u
TP.102/744
On chest of man feeding drum and
opening machine
54
982 Asbestos 3.0/ Cement 0.65/v
/1A0027J
The sampling in each case was done over a period of half an hour, spray was carried on continuously during this period. In the case of TP.101/739 and TP.102/710 there were a number of short stoppages for blockages in the gun and this probably accounted for the results being lower, than TF.101/711 and TP.102/71-2.
In order to assess the health hazard the results should be considered in conjunction with those obtained in the spinning room
of J.W. Roberts Ltd. on July 20th, 1933 with the thermal precipitator.
In the "Report on Conference between Employers and Inspectors
concerning Methods of Suppressing Dust in AsbestosThxtile Factories'1
published in 1931, the Committee agreed that for practical purposes
the conditions arising from flyer spinning carried on without
exhaust under good general conditions should be taken as the
"dust datum".
^ ?'.-y h^
^ /, - /, * / .v
.
In Mr. Cbodall1 s peport on samples ..taken in 1938 he obtained
counts of asbestos fibre between''410 particles per c.c. and 165
.
particles per c.c. in a good flyer `spinning ^room.
.
I
Therefore it can be said that for the ..latest machine with
predamping in the opening machine,the.exposure to asbestos fibre is
about that of a good flyer spinning room and for asbestos predamped
in a cylinder the exposure to asbestos'is substantially below that I
in a flyer spinning room.
1 vkv ", cp
'
It must be emphasised that the object of the measurements
was to compare the throe methods of spraying and the measurements show
conclusively that the predamped method exposes the workers to the
lowest concentration of dust.
.
The measurements were carried out in a room in which no ventilation wa3 provided during spraying. At the end of each period of sampling the dust was cleared by means of fans before the next
determination was carried out.
In actual 'practice higher concentrations would be found 'an
confined spaces and in similar rooms where spraying was carried on
for a longer period.
'
(Sgd) J.3. EVANS.
M00279