I. AMERICAN INSULATED WIRE CORP. PAWTUCKET, R.l.
ES- 11295
approy.
0 4/VaC
TYPE: UL Listed AWM Style 5195 Having AWM 5036
REV. DATE by
(AF Style) Inner Covered With 10 Mil PVC Jacket *
frr>-
V
REASON
CUSTOMER: Leviton Mfg. Co.
ORDER NO: 78559
EA
I
4
i
TABLE I
Item No.
1 2 3
Size AWC
18 18 18 .
Stranding
Solid 7 x.0152M 16 x.010"
Cond. Lay Max.
___ .73" 2"
Cond. O.D.
.0403" .046" .048"
Asbestos
Tape
Wall
Width + .003" i
3/8" 3/8" 3/8"
.030" ,030" .030"
Diameter Over Asbestos
.108" + .003" .111" + .003" .113" + .003"
Diameter Over PVC
Jacket -* *003"
.130" .133" .135"-
i*.-
16
Solid
--
.0508" 3/8"
.030"
.119" + .003"
.141"
I5
16
7 x.0192" .92" .058" 7/16" .030"
.122" + .003"
.144" *
6 16 26 x.010" 2"
.060" 7/16" .030"
.124" + .003"
.146"
7 14
Solid
-- .0641" 7/16" .030"
.132" + .003"
.154"
8 14
7 x.0242" 1.1" .073" 9/16" .030"
.138" + .003"
.160"
noo
l+ l
f-t
H
9 14 41 x.010" 2"
.078" 9/16" .030"
.165"
10 12 11 12 12 12
13 10 14 10 15 10
Solid 7 x.0305" 65 x.010"
1.4" 2"
Solid 7 x.0385" 104 x.010"
___
1.8" 2.5"
.0808" .092" .101"
9/16" 3/4" 3/4"
.1019" 3/4" .116" 3/4" .126" 3/4"
.045" .045" .045"
.045" .045" .045"
.181" + .005" .186" + .005" .195" + .005"
.202" + .005" .208" + .005" .218" + .005"
.203" . 208" .217"
.224" .230" .240"
1. Conductor: Annealed Copper Solid or stranded, Bare or tinned. Dimensions Per Table I.
2. Separator: A Brown Cellulose Acetate Tape .002" shall be wrapped helically vith a 502 overlap. Sec Table I for Width of Tape.
3. Insulation: Felted Asbestos ^238, 1500 Crain Underwriters Quality shall be applied directly over the taped conductor. See TABLE I for Walla and Dimensions.
(.
s 0108
/ AMERICAN IN5ULAl tt> nmt vunr.
PAWTUCKET, R.I.
-2-
-
ES-11295
U. Finish Over Asbestos: The insulated conductor shall be saturated vith AT WAX,
Colored as ordered,
*
NOTE: Paragraph 2, 3 & 4 shall be done in 1 operation*
5. Outer Jacket: Outer Jacket to be colored as ordered.
For 60 C use Apex 130 for standard colors and Apex 586 for Clear and setallie colors
For 105 C use Apex 842'for standard colors and Apex 716 for Clear and metallic colors
Non. Wall: .011" + .002"
Norn, 0.0.: See Table I
NOTE: A 3-foot sample muat be sent to each Q.C. Area for Inspection
6. Inspection:
*
Spark Test: 6000 Volts
Inner:
Per UL-AWK 5036 (AF Style)
. *. *
.
Continuity: 1001
.
7. Packaging: Standard Commercial Practice or as specified.
;
8. Tag Markings: Wire to be tagged and labelled as follows: l
1. American Insulated Wire Corp.
.
2. Sir.fl AWC 150 C 300 Volte (1/32" Ins. 18-14AWC) or (3/64" Ins. 12-10AWG)
.
3. Style 5195 With 10 MIL THICK PVCJKT.
.
4. Appliance Wiring Material suitable for the Internal Wiring of Heating Appliances.
5. As non-enclosed visible vires other than lamp-supported lamp holders or enclosed wiring.
6. UL Appliance Wiring Material labels equal to the footage + 10Z.
:< k
: ::3 ':{ * .;I
Written By: J. Medeiros Checked By: A. Petit Q.C. Check: M` Pachcco
t r*x ;si 0109