Document zbvEzxMYZBv0V54N6xNjmGV6a

.i I. AMERICAN INSULATED WIRE CORP. PAWTUCKET, R.l. ES- 11295 approy. 0 4/VaC TYPE: UL Listed AWM Style 5195 Having AWM 5036 REV. DATE by (AF Style) Inner Covered With 10 Mil PVC Jacket * frr>- V REASON CUSTOMER: Leviton Mfg. Co. ORDER NO: 78559 EA I 4 i TABLE I Item No. 1 2 3 Size AWC 18 18 18 . Stranding Solid 7 x.0152M 16 x.010" Cond. Lay Max. ___ .73" 2" Cond. O.D. .0403" .046" .048" Asbestos Tape Wall Width + .003" i 3/8" 3/8" 3/8" .030" ,030" .030" Diameter Over Asbestos .108" + .003" .111" + .003" .113" + .003" Diameter Over PVC Jacket -* *003" .130" .133" .135"- i*.- 16 Solid -- .0508" 3/8" .030" .119" + .003" .141" I5 16 7 x.0192" .92" .058" 7/16" .030" .122" + .003" .144" * 6 16 26 x.010" 2" .060" 7/16" .030" .124" + .003" .146" 7 14 Solid -- .0641" 7/16" .030" .132" + .003" .154" 8 14 7 x.0242" 1.1" .073" 9/16" .030" .138" + .003" .160" noo l+ l f-t H 9 14 41 x.010" 2" .078" 9/16" .030" .165" 10 12 11 12 12 12 13 10 14 10 15 10 Solid 7 x.0305" 65 x.010" 1.4" 2" Solid 7 x.0385" 104 x.010" ___ 1.8" 2.5" .0808" .092" .101" 9/16" 3/4" 3/4" .1019" 3/4" .116" 3/4" .126" 3/4" .045" .045" .045" .045" .045" .045" .181" + .005" .186" + .005" .195" + .005" .202" + .005" .208" + .005" .218" + .005" .203" . 208" .217" .224" .230" .240" 1. Conductor: Annealed Copper Solid or stranded, Bare or tinned. Dimensions Per Table I. 2. Separator: A Brown Cellulose Acetate Tape .002" shall be wrapped helically vith a 502 overlap. Sec Table I for Width of Tape. 3. Insulation: Felted Asbestos ^238, 1500 Crain Underwriters Quality shall be applied directly over the taped conductor. See TABLE I for Walla and Dimensions. (. s 0108 / AMERICAN IN5ULAl tt> nmt vunr. PAWTUCKET, R.I. -2- - ES-11295 U. Finish Over Asbestos: The insulated conductor shall be saturated vith AT WAX, Colored as ordered, * NOTE: Paragraph 2, 3 & 4 shall be done in 1 operation* 5. Outer Jacket: Outer Jacket to be colored as ordered. For 60 C use Apex 130 for standard colors and Apex 586 for Clear and setallie colors For 105 C use Apex 842'for standard colors and Apex 716 for Clear and metallic colors Non. Wall: .011" + .002" Norn, 0.0.: See Table I NOTE: A 3-foot sample muat be sent to each Q.C. Area for Inspection 6. Inspection: * Spark Test: 6000 Volts Inner: Per UL-AWK 5036 (AF Style) . *. * . Continuity: 1001 . 7. Packaging: Standard Commercial Practice or as specified. ; 8. Tag Markings: Wire to be tagged and labelled as follows: l 1. American Insulated Wire Corp. . 2. Sir.fl AWC 150 C 300 Volte (1/32" Ins. 18-14AWC) or (3/64" Ins. 12-10AWG) . 3. Style 5195 With 10 MIL THICK PVCJKT. . 4. Appliance Wiring Material suitable for the Internal Wiring of Heating Appliances. 5. As non-enclosed visible vires other than lamp-supported lamp holders or enclosed wiring. 6. UL Appliance Wiring Material labels equal to the footage + 10Z. :< k : ::3 ':{ * .;I Written By: J. Medeiros Checked By: A. Petit Q.C. Check: M` Pachcco t r*x ;si 0109