Document zbQXnYQRvJByX60ZBgOJG7O7g
TABLE PAGE 2
ASBESTOS RELATED PROBLEMS, COMMENTS AND SUGGESTED SOLUTIONS
ITEM
DESCRIPTION
COMMENTS
SUGGESTED SOLUTIONS
i. Asbestos cloth
Same 2.h.
(insulation fittings)
Same as 2.h.
J. Fire resistive Fibrated Asphalt Cut-back
.k Fibrated Asphalt Dispersion
.1 Asbestos paper
Same as 2.f
Same as 2.f. Probably safe to handle
Same as 2.f.
Same as 2.f. Personnel monitoring to verify claim
m. Flexible Braided Asbestos Tubing
Possible Source Personnel monitoring to of high exposure verify claim
.n "Tedlar" Neoprene Probably safe to Same as 2.1* Asbestos Laminate handle
.0 "Hypalon" Neoprene Same as 2.1 Asbestos Laminate
Same as 2.1.
P- Fibrous Adhesive
Contained, no problem
None required
3. a. Insulation Storage Possible source Thorough vacuum cleaning of high exposure repeat periodically.
Personnel monitoring to
verify claim.
4. a. Dismantling
Possible source Soak with water. of high exposure Personnel monitoring
,b. Installing Calcium Silicate Insulation
Probable source Personnel monitoring. of high exposure Substitute as quickly as
possible.
c. Waste Disposal
Regulated by OSHA Follow 37 FR 11321 Part 1910.931 h.2.
DUP 0902841 J29993