Document zbMwYRB0Y1apEVba8M0ZL5Qgg

/*Tr, n; /. "> . ;. oj Pont or \rouss S Cov.Pmny '**ci***Tr^ Wi'i..ViiNGTCN. DcUAWARE lsie rILC riBCnS DCPARTMCNT P/OrNtC Covered .... Z.. Z.-.k.'io. - v_U.e z S. A. Nursery - Camden E. L. Long - Kinston G. 3. Kirkpatrick - Old Hickory J. C. Exley - Martinsville N. C. Hrr;ez - Seafora L. 3.7/ilscn - Chestnut Hun E. M. O'Donnell - Waynesboro K. P. Coon - Cooper River T. J. Hampton - Spruance .5,,. -\\\ cuBivferr - Chattanooga___ W. D.Holman E. H.Shade T. S. Voorhees K. Eemerscheia - Geneva rebruary7, 1S77 C. J. TERRELL - Athens L. L. DeFANTI - Camden W. J. MANEY - Cape Fear H. E. SWINX - Chattanooga L. ELLISON, JR. - Chestnut Run W. D. RHODES - Cooper River L. E. GLASS - Kinston 3. iVI. CLOUD - Martinsville w. H. BURROUGHS, JR. - Old Hickory J. C. 3R0WN - Seaford C. L. AERAMS, JR. - Spruance E. S. CROW, JR. - Waynesboro F. G. GCYETTE - Coteau J. W. MCCRE - Kingston H. A. JOHNSTON - Maitland -H. STOLZXE - Uentrcp T. M. DUF.ICX-- Dordrecht K. A. CANAVA.X - Maycovn J. H. BEATTIE - Luxembourg L. MYLES - Iran (Bellaire) ASBESTOS POLICY In June, 1974, J. k. Sigman issued the Textile Fibers Dust Exposure Guidelines (a copy is attached) and we now feel it is timely to summarize the events since the issuance of the Guidelines and state our current position. In October, 1974, the Construction Division proposed an identification procedure which they would use to fulfill their responsibility7, under paragraph. 5 of the Guidelines which requires asbestos free insulation to be identified. Review of their proposal and comments from the plants lec us to the conclusion that ii was too late to adopt one common system across the Department since most plants had already a viable system in operation. ? 464 \ v7f\ < V r v, */ > DUP 0903947 SC-DP-05175 It ".-as ivoted that four plants allowed seme term c: i-ating and those pl.-ms / were again encouraged to discontinue this practice. In April, 1975, we responded 1: a notice in the Eederal ?.e sister dated March 19, 1975, and chanced re cord peeping retention,frc m _thre e years.io twenty years. The Guideline allows the use c; asbestos containing materials under carefully controlled conditions where acceptable substitutes are net available. Ey definition we did not have acceptable substitutes for Marinite cr A Cloth when the Guideline was issued and this office was charged with developing acceptable substitutes for these materials. Therefore, even though our goal has been not to use or work with asbestos in the future, we have had to accept these two materials, in September, 1976, you received a letter recommending the use of Marinite XL. a Johns ManvUle developed product, which was asbestos free. This product had been tested by the Engineering Department ana several of cur plants and was found to be fully acceptable as a replacement for asbestos containing Marinite. Thus, the only asbestos containing material which we do net have an acceptable substitute for is A Cloth and the attached Guidelines are changed tc reflect this. Cur efforts to eliminate A Cloth have been direected a: replacing it with fiberglass. Two major problems must be dealt with in this approach: 1. Tie attack Of the ccmmcn sodium silicate adhesives cr. :he fiber glass cloth at elevated temperatures. 2. The deterioration in structural strength and increased friability cf the calcium silicate insulation due to the reels cement c: the asbestos binding fibers with nonasbestos fibers. The first of these two problems have been largely overcome by the use -- _ of a proprietary product originally called "Torterlag", new called "Coverrard1'.: .A J in certain applications. This product is a fiberglass cloth with a rewettable " ' " adhesive already applied to it. The adhesive is an inorganic proprietary substance. This material has been used and is recommended for use in locations net sub jected to moisture, elevated temperature, abuse or occasional removals - In locations subject to moisture, elevated temperature, abuse or___!v^^''r<- do occasional removal, we consider calcium silicate with A. Cloth covering l acceptable a: this time. In these locations, our etneidate for elimination o: ' A. Cloth is an insulation system (called soft blankets) consisting c: a fiberglass ' DUP 0903948 t: + C. ^ c ; * Y*. * ; W* - v^v.----------' oy OvT . ce::er eu;- seals end 1-1 factors (for eeuLulerk thickness'- ana pb yuical abuse rr.sU.tur.ee while satisfactorily overcc mir.g the evo pro clems 1L -"UG*. -Vi W. --IT. CCiv, io toe variable to make a general statement that cr.e U b-:i-:-r then the ether, however, it can be said the cost is so close that it a: :'stably uoes net Lnfluer.ee the decision. Many of our plants are.testing this .system actively new and ^ firm recommendation on this final elimination of asbestos is at least a year away. The deterioration of the calcium silicate insulation, mainly due to the replacement of the asbestos binding fibers, is extremely variable by manufacture and in some cases by production unit within one company that our recommendation is to use Johns UlanvUie Thermo 12 or a brand which you know is equally reliable. The last item is the proposed CSHA standard 'which you have reviewed and commented cm Cur comments have beer, integrated intc a Company statement which was entered into the record. The expect this standard to be publicised sometime in 1577 ana have recommenced no action be taken until that time. When this standard is publicized, we will conduct a meeting to develop guideline changes ana to insure uniform compliance. Ih summary, cur guidelines are viable -with me understanding that :he only asbestos containing material which we do r.ot have ar. aoceptahls subsiimte for is A Cloth. This use is restricted to new installations cr fabrications 7,'here moisture, elevated temperature, abuse cr occasional removal are enco-tmered. ) v v^-r'/SSC Aft. :?tn3 dppivr'cr-*'v .*v S' ft -tas.-cy Encrt^eerinr .Assistant DUP 0903949 It is the policy c: the Textile Fibers 2c:^s\~-irt.o0 comply with CSHA *gl .lions, Section 19101 93a, and, where cood industrial hygiene practice and/or ?rsonnel relations indicate, to go beyond legal requirements. The following recom.enaations are for your guidance in implementing an asbestos dust control program: 1. To minimize personnel exposure, the use of all asbestos materials in 0 ^ new installations and fabrications shall be discontinued where acceptable substitutes are available. Where acceptable substitutes are not available, asbestos containing materials will be used under carefully controlled con ditions. 2. All asbestos containing insulation shall be removed from inventory except for those few items where acceptable substitutes have not beer, developed t (i e., "A" cloth, tape, etc.). ^ 3. Discard all damaged (requiring repair) asbestos containing insulation when it is removed and replace it with asbestos free (AF) insnlau.cn. This does no; include "A" cloth and so called "suitcase" or "removable" insulation which has a durable cover to minimize handling damage nor does it include -v marinite. . Insulation materials to be discarded are to be handled in accordance with regulations to minimize dusting by sealing in dust-proof containers (L e., polyethylene bags or equivalent) and disposed of by acceptable landfill procedures. ^Removed pipe, duct, and equipment insulated with asbestos materials shall be identified prior to disposal through Salvage sale to scrap dealers. l) DUP 0903950 and housekeeping standards. Construction will identify asbestos free insulation in a manner acceptable to plant management When asbestos containing materials are fabricated f ' A" Cloth, etc. ), approved exhaust systems, downdraft work tables, or tools are to be used: a) Permanent installations in the shop areas b) Portable units in the field . Prohibit the practice of eating food, snacks, drinks, or placing materials such as gum or tobacco products in the mouth in work areas where asbestos containing materials are handled or fabricated. " ' ' ' VThen working in areas where applicable limits of asbestos fibers are exceede all outer clothing worn on the job that day shall be furnished and either dis posed of or laundered by the Company. In the interest of good Industrie! hygiene and personnel relations, exposed clothing cannot be worn c~ the plant nor shall it come into contact with the person's street clothes. Wher. the applicable exposure limits to asbestos fibers are exceeded, appropriate respirators shall be worn. `- Capability for sampling and measuring fiber and dust counts should be developed each site. Personnel should be appropriately trained and certified, Standard Methods should be rigidly followed, and inter-laboratory checks should be periodically performed to assure accuracy and consistency. Annual X-Hay and pulmonary function tests should be performed on all personnel regularly exposed to asbestos dust as a consequence of their normal assignment DUP 0903951