652 CHAPTER 29 1954 Guide customers having a high load factor (relatively low demand), and those having a low load factor (relatively high demand). The utility company must maintain sufficient capacity to serve the high demand customers, and the cost of the increased plant investment is divided equally among the users, so the high demand customers are benefited at the expense of the others. 3. Demand Rates. These refer to any method of charge based on a measured CHAPTER 30 CENTRAL SYSTEMS FOR AIR CONDITIONING maximum load during a specified period of time. Thefiat demand rate is usually expressed in dollars per thousand pounds of demand Features of Systems, Zoning, Humidity Control, Cooling Load, Heating Load, per month or per annum. It is based on the size of a customer's installation, and is Air Quantity and Effectual Temperature.Difference, Low and High seldom used except where a meter is not practicable. The Wright demand rate is similar in calculation to the block rate, except that it Pressure Induction Convectors, Evaporative Cooling, Precooling, Sensible Cooling with Unwetted Coils, Run-Around is expressed in terms of hours' use of the maximum demand. It is seldom used, but System, Selection of Type of System, Location forms the basis for other forms of rates. of Apparatus, Design Procedure The Hopkinson demand rate is divided into two elements: (a) A charge based upon the demand, either estimated or measured. HE term, central, applied to an air conditioning system implies that (b) A charge based upon the amount of steam consumed. the equipment such as fans, coils, filters and their encasement are Ti This fate may be modified by dividing the quantities of steam demanded and con sumed into blocks charged for at different rates. designed for assembly in the field rather than in a factory as a unit. As a central system usually serves several different'rooms, individual con The Doherty rate is divided into three elements: . . , trols are required for each room. (a) A charge based upon demand. (5) A charge based upon steam consumed. |j i. i (c) A customer charge. FEATURES OF CENTRAL SYSTEMS One advantage of a central air supply system is that one apparatus In the Hopkinson rate, the last two elements are combined into one element. serving many rooms may involve a lower investment cost than that for a Demand rates are comparatively new and are not yet widely used. number of self-contained plants, each serving a single room. A central While they are equitable and competitive, they are difficult for the average layman to understand. They are of benefit to utility companies and to consumers because the investment and operating costs can be divided, to suit the particular circumstances, into demand, customer, and consumption groups through the use of some modification of the Hopkinson rate. De mand rates are an advantage to the customer in that the use of such a rate reduces the rate per thousand pounds to the long-hour user. system may occupy basement or attic space that is relatively unimportant, whereas individual factory-assembled apparatus placed in each room may occupy otherwise valuable space. Another advantage of a central system is accessibility for servicing, since it is possible to provide doors in the encasement for cleaning and inspecting all of the component parts in a manner usually superior to that practicable with compact factoryassembled equipment. Fuel Price Surcharge. It is usually desirable to establish a rate upon a Central air conditioning systems usually are connected by ducts with specified basic cost of fuel to the utility company. Where there are wide the various rooms served, and preferably have exhaust fans that may variations in the price of fuel, it is also desirable to add a definite charge effect complete removal and disposal of any desired proportion of the air. per thousand pounds of steam sold for each increment of increase in the The exhaust fan may return air to the supply system for recirculation, as price of fuel. This surcharge automatically compensates for the variations a measure of economy of fuel or refrigeration. without necessitating frequent changing of the whole rate structure. '1 Some utility companies include a labor surcharge as well as a coal-sur Central air conditioning systems are served by heating and refrigerat ing equipment which may be located at some distance from the air supply charge. apparatus, and which may serve one or more central air supply systems. Year-Round Air Supply System Fig. 1 is a plan of a year-round air supply system. Outside air may enter from the left at A, desirably, from an intake on the side of the buildrag least exposed to solar heat, and not close to the ground or to a sunheated or dust-gathering roof. The damper B for proportioning the volume of outside air, is interlocked with the return air damper C in such manner mat as the outside air volume increases the return air volume decreases. The return air duct D, shown diagrammatically, comes from the exhaust fan. All the air, it will be observed, must pass through the filters E, an[f there is ample room on both the inlet and outlet sides of the filters for servicing them. The filters may be of mechanically cleaned type, of replaceable cell type, or may be electronic, as described in Chapter 34. The cleaned air passes to the equipment that changes its temperature and humidity. Except in very warm climates, a heating or tempering coil F is required to warm the air to a temperature above freezing. Usu- 653