Document zXEJ4MJJMEvjaX2NNNOk2L8B
Instruments
laylor Instrument Companies
Rochester, N. Y., U. S. A
NEW YORK CHICAGO BOSTON
IN CANADA--Tatlob Instrument Companies op Canada, Ltd., Toronto
PHILADELPHIA PITTSBURGH CLEVELAND
LOS ANGELES INDIANAPOLIS SAN FRANCISCO
ST. LOUIS CINCINNATI TULSA
DETROIT ATLANTA MINNEAPOLIS
Manufaduririg Distributors in Great Britain, Short & Mason, Ltd., London
Manufacturers of Tycos Instruments for Indicating, Recording and Controlling Temperature, Pressure and Humidity
Tycos Suspended-
Pen Recorders--
Temperature
- t mm i
\\ ranges and time
/ /requirements vary
- \l greatly in heating
I and ventilating
work. Tycos Sus
pended - Pen Re
corders are made
in many scale
ranges and several
time periods to
meet these needs.
Tycos Recorders are sturdy and reliable.
The friction of moving parts has been re
duced to a minimum. Charts are easily
changed, and each instrument is locked
and sealed against'malicious or uninten
tional interference with the mechanism.
Cases are handsomely finished and are
dust and moisture proof. Instruments may
be quickly tested and calibrated. Write
for special information suitable to your
needs.
Tycos Electric Contact Temperature
Control--These instruments combine in the same case an electrically-operated
temperature regulator with an indicating thermometer. One tube system only is required to operate both units.
Direct-Set Control Feature--This feature has been developed in Tycos Electric-Contact Controls until we believe that no similar instrument on the market can compare with it for convenience and
accuracy. The Tycos Direct-Setting Feature is a real time saver, because it eliminates making a series of adjustments in order to obtain the proper control. Only one adjustment is required.
The instrument will control at this point within the limits of its contact until re-set for another temperature.
Tycos Thermometers for En
closed Spaces--The Tycos line presents many styles and scale ' ranges. Suitable for air ducts, ~ kiln temperatures and oven tem peratures. * Tycos Industrials Thermometers are made with the greatest care, and their reliability is unquestioned. For detailed information, writedirect, mentioning your requirements.
Tycos Self-Acting
Temperature Regulator--Is adapted, to usef on hot-water storage tanks, etc: It is "selfacting" in that it requires no auxiliary motive power, such as compressed air, to open and close the steam valve. Asheatis applied to the bulb the volatile liquid in side sets up a vapor pressure proportional to the tempera ture. This pressure is trans- j mitted to a "stack" of metal I diaphragms attached to the * upper end of the valve stem, thus moving the valve disc toward the valve seat. By means of the adjustment at the top of the diaphragm housing, the valve can be closed at any desired tempera ture, or a throttling action can be obtained within the temperature range of the instrument. Not practicable on pipe lines having steam pressure over 125 lbs. Should be installed in a vertical position bn top of the line; never hanging under neath the line. The line itself should be horizontal rather than vertical. Operating range 100 deg. to 160 deg.
716
Taylor instrument Companies
Instruments
fahr., 140 deg. to 212 deg. fahr., or 190 deg. to 270 deg. fahr., as specified.
Tycos Sling Psychrometer--
The Tycos Sling Psychrometer is a modification of the pattern developed by the U. S. Weather Bureau. The fact that our design has been generally copied is good evidence of its practicable features.
The advantage of this form of Wet-and-Dry-Bulb Hygrometer I., over the stationary form is the I facility with which tests can be made and the accuracy of the readings obtainable, as in whirling the bulbs they are subjected to perfect circulation.
Tycos Recording Regulator--Recom
mended for applications where it is neces sary to change control points often. This in strument regu lates one or two temperatures o r pressures and re cords one or both at the same time. Can be used to control wet and dry-bulb tem peratures in closed spaces. Setting is
made directly by moving a pointer to the desired temperature on the chart.
Tycos Humidi-
guide--A hand some small hygro meter for the wall of the home, office, school or other building where a neat, easy-reading and inexpensive instrument is de sired. It is selfcontained, requir ing no charts or separate tables. Frame is Ma hogany Bakelite.
Tycos Record
ing Hygro-. meter--Thisin-
strument re cords both wet and dry - bulb temperatures on
the same chart in different colored inks, making compar ison very easy.
Type shown above with motor-driven
fan for conditioned rooms or passages in which circulation is poor. Can be supplied without fan for installations where circu lation across bulb is good.
Tycos Type-P Regulator--A compact
and very sensitive regulator, ideal for airducts, air-washing machines, cooling rooms and similar applications. Uses compressed air as an actuating medium. .
Tycos Hygrodeik--This self-contained
hygrometer is designed for air-ducts, kilns, driers and similar applications. Mounting is made through wall into enclosed space. Thermometers are highly accurate Tycos Industrial type and water reservoir is of generous capacity.
Write for additional information on any of the Tycos Instruments on this page.
717