for general d ij:rib -*iip r- ,r'republit ation \d^\ j. JOHNS-MANVILLE RESEARCH AND ENGINEERING CENTER MASTER FILE COPT Report No. Date 425-T-1357 September 2, 1971 Title: TRAUSITE PIPE TEST LIRE - "F" and "G" Series SUMMARY The "F" and "G" series of experiments in the program to evaluate the rate of removal of chrysotile asbestos fiber from the inner walls of TRARSITE pipe, have been con cluded. These latest series represent a continuation of the program, data from which have already been reported through the "E" series. Average values for water pH and hardness were: "F", pH 6.0, hardness 25.6; and "G'VpH k.y, hardness 12.3- These represent an increase in acidity and a decrease in hardness when compared with the waxer used for the "E" series. Fiber concentrations ranged from: "F", 0.1 x 10"5 to i+.8 x 10"5^ug/gal: "G", 0.1 x 10-5 to 30.2 x. 10"5 yUS/gal. A computer analysis has been made from these latest test runs together with data from earlier runs which used water of greater hardness and higher pH. This analysis shows that in all cases the rate of removal of fiber decreases with time. Comparison of . data from one test run to another revealed no apparent relationship between the rate of removal and changes in the pH/hardness combination. I . J Contents: Introduction, Experimental, Results and Discussion, Appendix (Tables 1-3) 4 (Figures 1 through 3) pmp cc: F. L. P'undsack (S) J. P. Leineweber Attn: S. Speil P. E. Dix J. F. Herr S. M. ^uint A. F. Burns D. H. Hamer K. L. Kindery(2) D. H. Hamer Basic Chemistry Research Section JM C'ONFIDHNTIAL. him, jj T.0 Pile 1 JOHNS-MANVILLE RESEARCH AND ENGINEERING CENTER Report No. 425-T-1357 Page l JM c o n f id e n t ia l . N ot ftu flattenii distribution or rip u b lii ation. INTRODUCTION This report is comprised of data obtained from the latest series in a program in tended to determine the rate of removal of chrysotile fiber from TRANSITE pipe walls by potable water under varying controlled conditions of pH and hardness. Data reported here cover the "F" and "G" series of test runs which used water with averages of pH 6.0, hardness 25.6 and pH 4.9, hardness 12-3 respectively. The duration of the "F" series was from November l6, 1970 to March 19, 1971; the "G" series from March 29, 1971 to June 4, 1971- Data from earlier series run with higher pH and hardness values have been reported in Reports No. 404-56, 404-63, and 404-75* This report includes discussion of the earlier results in comparison with the latest reported data. EXPERIMENTAL The analysis and sampling procedures were the same as those used in the "E" series except for relocation of the water softener to the inlet water line before commence ment of the "G" sampling series. This was done on the recommendation of the water softener manufacturer and is related to minimum pH requirements for the Zeolite bed. (See Report No. 425-Int-1363, S. M. Quint, June 7, 1971) Filters removed from the pipe loop were ashed, radioactively tagged and rubbed out. Electron microscopy was employed to produce micrographs representative of the material present in the ashed residue. The electron micrographs were then scanned visually and fiber counts performed. These were then extrapolated to calculate fiber per unit volume of water. RESULTS AND DISCUSSION Table 1 of the Appendix lists the average values for pH and hardness of the water used in the test series "C" through "G". The fiber analysis results obtained for the "F" and "G" series are tabulated in Tables 2 and 3 and expressed graphically in Figures 1 and 2. Fiber concentration reported for the "F" series ranged from 0.1 x 10"5 to 4.8 x 10*5 yug/gal; for the "G" series from 0.1 x 10*5 to 30*2 x 10~5 ^ug/gal. These values are of the same order of magnitude as those reported for the preceding test series. Because of the apparent closeness of the fiber concentration values among the various test series it was decided to perform an Analysis of Variance by computer. JOHNS-MANVILLE RESEARCH AND ENGINEERING CENTER Report No. 425-T-1357 Page 2 This analysis, performed by S. E. Lawrence of the 3asic Physics Section shows that at a significance level of 95 per cent, the rate of removal of fiber from the walls of a TRANSITE pipe, under the test conditions, does not vary with changes in pH and hardness. Linear regression analysis does, however, indicate that in all cares the rate of erosion does decrease with time. This decrease in erosion rate with time is greatest for test runs "E" and "D" and least for test series "F". Run "C" and "G" fall between these, but are closer to "F" The results of the linear regression analysis are depicted in Figure 3* In this graph the posit- on of each curve peak on the "x" axis represents the mean slope of the straight line generated for a particular test series by the regression analysis. The area under each curve being unity the "y" coordinate is simply re lated to the spread of the data points. The area under a curve which lies to the left of the origin is an indication of the probability that the slope of tliat particular straight line is negative. To summarize the results obtained to date in the TRANSITE Pipe Test Line experiments, we can say that for a given pli/hardness combination the rate of removal of chrysotile fiber from the pipe wall decreases with time. However, statistical analysis of the data reveals no relationship between this rate and the various pH/hardnesa changes. JM CONFIDENTIAL. N o t for general distribution or republicotion. JOHNS-MANVILLE RESEARCH AND ENGINEERING CENTER ReportNo. Page 425-T-. 257 3 APPENDIX Table 1 Average pH and Hardness - Series "C" through "G", TPTL JM CONFIDENTIAL. N ot fo r general distribution orrepubliLOtiipn. Series pH Hardness C DE F G 7-2 105 7-3 51 7-3 24 5.0 25.6 4.9 12-3 JOHNS-MANVILLE RESEARCH AND ENGINEERING CENTER Report No. Page 425-T-1357 4 JM CONFIDENTIAL. N o t fo r generut distribution o rre p u b licu iiitn . APPENDIX Table 2 Ash Content and Fiber Concentration - "F" Series Run Ho. Water Sampled (gal) Ashed Solids (ns) Fiber in Ashed Solids (per cent) Fiber in Water Gug/gal) 1 133,920 2 85,900 3 87,100 4 . 87,050 5 87,100 6 85,700 *7 i 82,000 3 30,300 9 92,160 10 91,500 42.2 37-0 33.6 28.7 28.7 35.^ 32.8 36.9 32.1 35-2 0.0061 0.011 0.0095 0.0017 0.0017 0.0004 none detected 0.0062 0.0005 0.0040 0.1 x. 10-5 4.8 x 10-5 3-6 x 10-5 0.5 x 10-5 0.5 x 10-5 0.1 x 10-5 . none detected 2.3 x 10"5 0.1 X 10-5 1.5 x 10-5 Average fiber in water = 1.4 x 10"5 ^ug/gal JOHNS-MANVILLE RESEARCH AND ENGINEERING CENTER Report No. 425-T-1357 Page 5 CONFIDENTIAL. N u i /or general diilribnuon or republictilinn. APPENDIX Table 3 Ash Content and Fiber Concentration - "u" Series Fun No. Nator Sampled (gal) Ashed Solids (mg) Fiber in Ashed Solids(per cent) Fiber in Water (ng/gai) 1 58,500 10-3 lL 65,loO 35-6 3 83,930 46.5 4 71,700 U0.3 5 88,600 67.3 5 83,200 39-0 7i 78,100 33-1* a 67,300 3^.1 9 85,300 43.3 10 58,300 59-4 0.020 0.0025 0.054 0.0021 0.018 0.0004 0.043 0.015 0.012 0.0010 9-0 x 10-5 1-3 x IQ'5 30.2 x 10-5 1.1 x 10-5 14.0 x 10'5 0.1 x 10-5 18.4 x 10-5 7-6 x 10-5 5.2 x 10-5 1.0 x 10-5 Average fiber in water = 8.89,,ug/gal F ib e r per g a llo n Figure 1 Report No. 42J-T-1357 F ib e r per g a llo n Figure 2 "G" Series TPTL Report Ho. U2^-T-13;7 PaSe 7 r F ig u re 3 R e p o rt No. k2'.>-T-iyyT 3 L0 PF