Document zQvrknEjek170Dbo6Bk2onORB
2669
-b 18 ..
1 2
3
4
5
6
7
8
9
10
11
12
13 .4
14
15
-16
17
' 18
19
20
21
22
23
24
I Reporters, Inc.
25
tank cars may drip while they're being unloaded, or there
may be some drippage or spillage, and that this operation is
open to the weather.
A. Yes.
Q. Now, "i'm asking if this were covered over, wouldn't
that reduce the discharge of PCB's?
)
A. Oh.
.*
I think another way -- and it slipped my mind
whether we were thinking about this or whether we were doing
this -- is just to put the spout in a drip-catcher. We
have been thinking about things to make sure that any drip
simply went into a glove.
Ql Well, the question I asked was if the unloading
area were covered and protected from the rain, couldn't that
have the effect . of reducing the amount of PCB's that leak
out into the effluent?
A. I don't know.
I think it's a kind of a hard thing to say because
you could say, "Well, in any one trip it might," but in the
overall . sense that material is going to move. It transports
from a variety of ways -- dust, vapor -- and I could not
guarantee it would be negative.
Ql What precautions are taken to avoid accidental
spills during unloading operations?
A. Well, of course, there'is very strong adsiinists
DSW 315093
STLCOPCB4055558
2670
1 control in the process, but I think the process itself, with 2 it's top-loading arrangement, goes a very, very long way to 3 eliminate practically-conceivable spillage accidents.
4 Q. How about on the storage i.emks themselves? Are
5 there high liquid level alarms on
storage tanks?
6
, A-
I doubt that there are high liquid level alarms.
7 People, again from good administratevo control, know the
8 quantity of PCB in that plant in thfse tanks at all times. 9 Q. What type of control at the transfer lines and the
10 tank drain valves is employed?
.
11 A Tank drain valves?
12 & As you drain from the stc rage tanks.
13 A Well, yes. Okay.
14 We put from there into the process. I was thinking
15 about drain on the basis of removing undesirable contents
16 from the thing, and there is no such system.
17 Ql Is that done also?
18 A No. That's why I wanted a definition of your
19 drain.
20 The transfer line that goes from the tank to the
21 process is, of course, a closed pipe that is manifolded througi
22 valves to be sent to whatever portion of the Sharon plant
23 the ?C3's are used in.
24 JUDGE SWEENEY: Let's take a fifteen minute recess
Inc.
25 (Recess.) DSW 315094
2671
1 JDDGE SWEENEY: Back on the record.
2 Mr. Eckert?
3 BY MR. ECKERT:
4 Qi Dr. Wright, you have discussed some of the levels
5 of*PCB*s being discharged from the "Sharon facility.
VS '
Have you investigated what types of PC3's are
7 present in those discharges?
8 A. Yes.
9 It is my recollection that our analysis of the
10 homo logs present reflect that there is quantities of .1254
11 and other material that was used in the distant past.
12 In relation to this I should like to make a correc
13 tion to the record. At the Sharon plant and our transformer
14 plants, we use 1242, not'1016. I was relating to the capaci
15 tor plants.
16 ft So then the capacitor plants use 1016 primarily;
17 is that correct?
18 A Yes. That's correct.
19 Qi Do the capacitor plants use any 1242?
20 A This is where I say.it's in the process of phase-:
21 out; whether it's completed or not, I don't know.
22 MR. MC LAIN: No Aroclor 1254 is in current use in
23 the capacitor manufacturing plant in Bloomington.
24 JUDGE SV7EENEY: Do you accept that correction,
Inc.
25 Dr. Wright?
DSW 315095
2672
1 A. Yes, of course. .
2 BY MR. ECKERT:
3 Q. So we're still talking about two homologs, 1216
4 and 1016, and 1242? is that correct?
A
5 A. At the capacitor plants.
'
6 Q. Well, but at the transformer plant --
7 A No 1016.
8
Q.
Only one,'1242. Isn'tthat
right?
9 A Yes.
10 Q. Were you able to quantify how much of the discharge
11 from the Sharon plant was 1254?
12 A It is my recollection all the;material,looked like
13 1254, more nearly like 1254
.
.'
14 Q. Do workers in the plant who work around PCB areas
15 apply protective clothing? 16 A Yes, they have protectiveclothing, administrative
17 procedures, and warning signs. 18 Q. Is the protective clothing laundered on the site? 19 A No, it is not. They don't wear total protective 20 clothing as we would use, for example, in the nuclear areas 21 -- areas of radiation waste. We don't use cleanroom technique 22 from the standpoint of total coverage -- shoe covers, and 23 that sort of thing. 24 Q. What happens to leaking capacitors, rejects, and
Inc.
25 leaking transformers in these plants?
DSW 315096
STLCOPCB4055
2C73
1 What's done with them?
2 A. Well, in the case of the transformers, the material
3 is pumped back into good storage; and then the material that
4 remains, if it has to be cleaned, it is cleaned. And the
5 waste material'goes into the PCB waste tank, as described
6 before, and sent eventually to oxide incineration.
7 Qi How much time would be necessary to conduct lab
8 oratory and pilot scale studies to see if activated carbon or
9 some other treatment process could be used to control PCB
10 discharges?
.
11 A. Well, there are several levels that one would
12 have to undertake.
13 . If one would amend: one's question to say, how
14 much time would be required to develop the design for a
15 cleanup of all of these systems, then that's a fairly major
16 chore. I would anticipate it to be somewhere in the range
17 of two to eight years, depending on how successful you were.
18 Qi Well, assuming, hypothetically, you decided to go
19 with activated carbon;
'
20 How long would it take for you to get that on
21 line?
22 A. What size? I mean, I don't know how to design it.
23 Q. In other words, you'd have to know whether it was
24 required to treat the entire v:aste stream, or part of the
Inc.
25 waste stream; is that right?
DSW 315097
STLCOPCB4055562
2674
1 A. Well, I 'd have to know at least some of all thing? .
2 That's only part of it. I would have to know how large to make
3 the throughout
'.
4 I would have to know at what velocities I could
5 have through the. charcoal, assuming that-it worked at all, 6 before I got channeling? and if it didn't'work I'd have to
7 know what residual volume to have th:re so I would have some
8 idea of the frequency with which it should be changed, and to 9 get the change procedures worked ouc,
10 From the laboratory to the -- the laboratory work
11 .has. not been done. - After the laboratory work, the problem
12 of engineering design '<. development work is where really
13 the crucial work would be required. You would simply have to
14 have scientific information to make the design.
15 fit Well, you referred to the lab. But aren't there
16 several industrial installations in which activated carbon is
\4
17 now used?: So that there are full scale data?
18 A. Oh, sure, but for removing of different components
i? from a different stream. Oh, sure.
20 And their variation in performance is enormous.
21 It depends strictly on what's to be removed, and from what
22 stream.
23 .
Please understand that I don't even know if there
24 would be any separation 'occur by moving PCB containing
Inc.
25 water through a charcoal adsorber. It may come out the outlet
DSW 315098
STLCOPCB4055563
2675
1 in exactly the same content that it went in the inlet. 2 Qi You've suggested that effluent limitations for
3 PCB should be one percent of the quantity of PCB processed.
4 Under such c limitation, what would be the concen
5 tration of PCB in the effluent from the Sharon facility? 6 A. Well, first, let's go back and rephrase -- reunder
7 stand the proposal:
8 The one percent would constitute the upper envelope
9 It would have two additional criteria to meet.
10 One is that the bioconcentration of any element
11 destined for edibility by man would be maintained at or below
12 the :5 ppm level specified by FDA.
13 Secondly, if there were a particular situation
14 where this PCB-containing water was used in a feed stock
15 preparation, then that limit would be dropped by another
16 factor of ten.
17 Nov/, both those constraints, then, are working
18 within the envelope of the one percent release. In other
19 words, this is site-dependent, requiring on-site environ
20 mental data to substantiate compliance.
21 Qt Has Westinghouse attempted to measure the PCB
22 residue levels in the tissues of aquatic organisms in receiv
23 ing waters for its facilities?
24 K Yes, it.has.
Inc.
25 & Can you be specific about the levels which v:ere
DSW 315099
STLCOPCB405f
2676
1 found'anfi the facilities which were involved?
2 A. -Yes, I can; certainly in. the case of the Sharon -
3 plant.
4 In the Sharon plant, we found PCB levels on the
5 order of 2 ppm and less in fish flesh. 6 Q. Soma were as high as 2 ppm?
7 A. Yes.
8 Qi And this is based on whole fish measurement?
9 A. I believe the key is, the fatty tissue is the
10 principal concern. I believe this particular test was on the
11 whole fish.
.
12 Ql In which ^organisms were these levels found?
13 A. My memory is already shown to be defective in terms
14 of what the sample was based on. If you would like to pursue
15 this particular line of questioning, we have Dr. Munson here,
16 who can supply this data to you directly.
17 MR. ECKERT; Your Honor, this is a bit irregular,
18 but under the circumstances, I would like to call Dr. Munson
19 to examine him on this line of questioning.
20 JUDGE SWEENEY: Have you finished questioning Dr.
21 Wright? 22
MR. ECKERT: . Yes. As a matter of fact, I am throne
23 with Dr. Wright.
.
s
24 And if there is no objection from Westinghcuse, I
Inc
25 would like to -- let me say this: I'm through with Dr. Wright
DSW 315100
2677
1 if Dr. Munson can be available to answer these questions. If 2 not, then I'm going to have to pursue this with Dr. Wright to 3 the extent he can answer them. 4 _ JUDGE SWEENEY: Do you have any questions? 5 MR. WILLS: I have some redirect. 6 JUDGE SWEENEY: All right, then you are just 7 excused temporarily. Dr. Wright. 8 (Witness temporarily excused.) 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Inc,
25 DSW 315101
STLCOPCB4055i
2678
1 Whereupon,
.
2 THOMAS O. MUNSON
3 was called as a witness by the Environmental Protection Agency
4 and, having been first duly sworn, was examined and testified
5 as follows:
*
6 DIRECT EXAMINATION
7 BY MR. ECKERT:
8 Q Would you state your name for the record?
9 A Thomas 0. Munson. I'm a biochemist. .
10 Q You're a biochemist? 11 A I'm a biochemist, yes.
12 Q And you're employed by Westinghouse;e?
13 A Yes.
14 Q Could you describe the efforts which were made
15 to measure PCB residues in aquatic organisms in the receiving
16 waters of the Sharon plant, please?
17 A Yes.
18 We electroshocked some fish downstream from the
19 Sharon plant. The stream is not a very clean stream. There':
20 quite a bit of other industrial effluent in the stream, so
21 the only fish we got for our shocking were fairly good-sized
22 carp. So the number *which Dr. Wright referred to is based
23 upon wet weight in fillets of the carp.
24 And the number he mentioned was-- I think the
Inc.
25 highest value we did find v/-.s about two parts per million.
DSW 315102
2679
1 This would have been-- Aroclor 1254 was the closest standard.
|
2 Q Were any other homologs found?
i
3 A I don't believe so. It has been some time since--
4 This work was done more than a year ago. *
5 Q Are tfiere any other industrial dischargers or any
j !
j
;
6 dischargers at all of PCB's on this river/ to your knowledge,
7 other than the Westinghouse plant?
8 A To my knowledge, and r*.y l-.-st guess would be that
9 nobody would be discharging at love} ? in cur order of magni
10 tude. Our plant is very close to thi source of the water.
11 We're downstream from the dam just a short ways.
12 Q Did you measure the ambioit concentration of PCB's?
13 A In the water?
.
14 Q In the water.
15 A No, we did not. At that time we didn't have the
16 technical capability of doing so.
17 Q At that time was the level of PCB's discharged front 18 the Sharon facility roughly the same, greater, or lower than
19 the numbers cited by Dr. Wright?
20 A Okay. Let me explain to ycu.
21 The sequence of events was that we became concerned
22 about the possible impact that we might be having on the
23 environment around our manufacturing sites. This was several
24 years ago, and at that time we initiated an environmental
Inc.
25 survey which I pere**mrtd around the plants. DSW 315103
.
.... : '
.
.'
,1
......... .......................
STLCQpCB4o55568
2G80
1 Y7e were mainly interested in looking at sediments
2 and at samples of the biota. It was a limited plan, so that
3 in most cases wo could not do a very extensive sampling of all
4 levels in the food web. And at that tine we were not sampling
5 the effluent discharge or the receiving water, mainly due to
6 technical problems involved in doing this.
7 So the answer to your qu- 'tlcn is at the time the
8 biota were sampled, we did not have 'ata on the effluent
9 discharged. That data has only been generated in the recent
10 past.
'
11 Q So you're saying that the data on effluent quality
12 which Dr. Y7right gave us is data whi *.h was taken at some point
13 in time considerably after the study was made. Is that correct
14 A Yes, that's correct.
15 Q To your knowledge, have control measures been
16 instituted between the time the study was made and the time
17 that the measurements of effluent quality were taken that might
18 account for lowering of PCB's in the effluent?
19 .
A
Vos. Hy guess would be that if we sampled again
20 today, the conditions would be lower. I should not expect them
21 to be worse.
/
22 Q Thank you very much. Dr. Munson.
23 (Witness excused.)
24
Whereupon,
"
Inc.
25 JAMES H. WRIGHT
. DSW 315104
STLCOPCB4055569
2681
resumed the stand and, having been previously duly sworn, v;as 1
examined and testified further as follows: 2
MR. WILLS: Could we have about a two-minute recess? 3
JUDGE SWEENEY: You have no further questions of 4
Dr. Wright? 5
'
MR. ECKERm: 6
We have no further' questions of
Dr. Wright. 7
JUDGE SWEENEY: 8
.. We'll tab'.- v. very short recess.
(Brief recess.) 9
JUDGE SWEENEY: Back on tl'?. record. 10
11 REDIRECT EXAMINATION .
BY MR. WILLS:
"
12
Q Dr. Wright, to clear up one thing about silicon, 13
I believe you said silicon was used in capacitors? 14
A I'm sorry, if I did and if the record shows that, I 15
should have said in transformers. As far as I know, silicons 16
have never been used in capacitors. 17
.
Q Also, you indicated that the discharge into the 18
waters of Sharon was either two grams or four drops. Have you 19
recalculated that? 20
A Yes. It turns out to be 40 drops or basically two 21
grams per day. 22
Q Now in response to one of Mr. Eckert's questions, 23
24 looking at page 17 of your testimony, the 3400 to 8500 figure
Inc.
25 of workers involved was reduced down to 200, How did you
DSW 315105
STLCOPCB4055570
2682
1 arrive or what standard were you looking at to get the 200
2 people?
'
3 A I believe, Mr. Examiner, this is a very key point
4 in these PCB's. I believe that it will come up again in the
5 course of these hearings, that what ,r are basically con
6 vinced of is that much, probably 90 percent of our TCB dis
. 7 charges at the present time are the result of PCB that is
8 saturated in the ground, in sewer p'pas that may have been
9 sealed but are still leaking to cc-v.-.-ins with ground and
10 surface water to reappear.
11 I think we have-- At th: Sharon plant, for example
12 I think we have a problem that if w terminate all produc
13 tion, all use of PCB on that site, v:e would not terminate,
14 by any means, the release of PCB'c to the environment down
15 to the level of the proposed standard.
16 Now this poses, I believe, a very major problem.
17 To say if the standard were instigated it is accurate to
18 say that 200 people, workers at Sharon, would be affected,
19 but we must say if we interpret the standard to apply to on
20 going operations only, the active releases from current
2L operations.
22 If on the other hand the standard is to say from
23 all sources inc]uding those which are saturated in the ground
24 from tine past and from other sources that we simply cannot
Inc.
25 identify at the present time, them our only alternative
DSW 315106
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 _21 22 23 24
i, Inc.
25
:2683 '
would be to shut down the entire Sharon operation and all the people that are employed therein and terminate our
relationships with itf because we would never, in our opinion, be able to meet the standard for emissions from the former
spills in the area. And I think this is where we go very quickly in
that one plant from a matter of 20C people, with one inter
pretation of how the standard woul^ be. enforced, to a matter
of 45,000 in the alternative of paging that the plant, whether it's binding or not, is di.charging it and hence
would be liable.
MR. WILLS: No further -luestions, your Honor. JUDGE SWEENEY: Do you have any questions,
Mr. Eckert?
:.
MR. ECKERT: Just one.
RECROSS-EXAMINATION
BY MR. ECKERT:
Q You stated that the PCB's would still be dis charged if.your plant shut down tomorrow. Would one source of those discharges be runoff from the land on which cld
spills occurred?
'
A Yes, that would be one source; yes.
Q So that for such lands at least it is your opinion
that PCB's in the sediments might still become available to
the environment through runoff; is that correct?
DSW 315107 STLCOPCB405657
2684
1 A Yes. I think principally I am worried about what
2 is under that big plant. One of the first questions raised
3 was what about flushing out all of the old lines and every
4 thing else like that. . >
5 MR. ECKERT: I have no further questions.
'
6 JUDGE SWEENEY: Can I ask one question, please?
7 How long would you have to close the plant down
8 to prove the scientific correctness of your thesis?
9 THE WITNESS: Well, we are thinking new of doing
10 it. If the plant takes a mass vacation this summer, we
11 will at least have two weeks of opportunity to make these
12 tests, and I have certainly recommended that we do just that
13 very thing.
.
14 JUDGE SWEENEY:- Exhibit 81 is received in evi
15 dence.
16 (Exhibit 31, previously
17 marked for identification
18 , was received in evidence
19 (Witness excused.) 20 ' MR. ECKERT: Your Honor, I would like to ask at
21 this time if Mr. Carlson has conferred with his Counsel?
22 MR. CARLSON: I'm sorry to tell you that I was
23 unable to reach him.
'
24 MR. ECKERT: Well, at this point I guess we can
Inc.
25 defer it. Wa are very short on time today, your Honor,
DSW 315108
2685
1 and we have two more witnesses to get through, and I suggest
2 that we move on to Dr. Simons at this time. .
3 JUDGE SWEENEY: Very well.
4 Whereupon, ^
'
5 . EDWARD L. SIMONS
6 was called as a witness by the Environmental Protection Agency
7 and, having been first duly sworn, was examined and testified
8 as follows:
9 JUDGE SWEENEY: The written testimony on behalf
10 of General Electric is in four sections. Which ones are
11 you going to examine on, Mr. Eckert?
'
12 MR. ECKERT: Well, today I'm going to examine
13 Dr. Simons on Section 2, and perhaps one or two questions on
14 Section 4, which are the two sections of his material.
15 JUDGE SWEENEY: Will you be examining the other
16 two witnesses.
17 MR. ECKERT: I'll be examining Dr. Lauer tomorrov'
18 morning, and I have no questions for Mr. Farnsworth.
19 JUDGE SWEENEY: The entire written testimony, all
20 four sections, will be identified as Exhibit 82.
21 (The document referred to
22 was marked Exhibit 82
23 for identification.)
24
Inc.
25 DSW 315109
2686
1 CROSS-EXAMINATION 2 BY MR. ECKERT.: 3 Q Dr. Simons, I will refer you to Section 2. 4 A I have it. Thank you. 5 Q On the second page you give the low flow of the 6 Kousatonic River as 14 cfs. 7 Do you have data on the average seven-day, ten8 year low flow for the Housatonic? 9 A It is approximately I believe about 40, but I do 10 not have the specific data with me. It has been compiled and 11 published by the State of Massachusetts and is available. 12 Q On the top of the page you say "Application of 13 Section 129.09(c) to a GE plant." 14 Roughly how many GE plants manufacture products 15 containing PCB's? 16 A Four. 17 Q And which plants are they? 18 A Transformers are manufactured at Pittsfield, 19 Massachusetts, and Rome, Georgia. 20 . Capacitors arc manufactured at two closely21 related plants, one in Hudson Falls, Hew York, and the other 22 at Fort Edward, Hew York. 23 Q Which of these plants discharge into receiving 24 waters directly and which discharge into publicly owned
Inc.
25 treatment works? DSW 315110
2687
LO ,
All four discharge directly into navigable water-
2 ways.
3 Q Now as to the Rome facility, what is the receiving
4 vrater?
1
5 A There are drainage ditcher; from the plant, one
- ' 6 of which goes to th Oostanaula Rive?1:* which eventually flows
7 into the Coosa River.
8 The other drainage ditch goes directly to the
9 Coosa River.
10 Q Do you have flow figures for those rivers?
11 A I do.
-
12 Q Would you give them to me, please?
13 A Yes.
'
14 On the same basis as the regulations call for,
15 the seven-day, ten-year low flow for the Coosa River 1300 cfs,
16 For the Oostanaula , 455 cfs.
17 Q And what is the receiving water for the Hudson
18 Falls facility?
19 A The Hudson River.
20 - Q
And its low flow at that point?
-
21 A 1600 cfs. 22 Q And the Fort Edward facility?
23 A The same.
24
ieral Reporters, Inc.
25
Q You've given some detail about the levels of FCB's that would be required to be discharged. Could you tell us
DSW 315111
STLCOPCB4055576
2688
Jll 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 >.d 2A 23 24 erol Reporters, Inc. 25
for each of these facilities what: quantities and concentra
tions of PCB's are being discharged now? |
JA
We analyzed to get data for the Refuse Act permit
'
applications. The current discharge from the Pittsfield
plant from current production is approximately .1 pound per dciy.
Q Are you able to isolate discharges from current ,
production and discharges from old production?
A Isolate physically? Q Well, how do you distinguish-- Let me ask it that way. How do you distinguish discharges from current pro
duction from discharges from residues?
A We transferred, at about the end of 1972, from the use of Aroclor 1260 to the use of Aroclor 1254. When samples are analyzed, we attribute any 1260 peaks in the gas
chromatogram to residuals from past production and use only
the 1254 peaks to establish the levels of current discharge.
that is, discharge from current operations. Q Well, let me ask you about 1260. ' Do you have data
on the levels of 1260 now being discharged from the Pittsfield facility?
A They also run approximately .03 to .1 pound per day; almost the same as that from current production.
. DSW 315112 1
STLCOPCB4055577
2689
1 Q. Has an effort been made to elucidate or to identify 2 rather the sources of contamination of the waste stream with 3 these PCB's? 4 A. The contamination from past operations, or from 5 present operations? 6 Q. From present operations. 7 A. We have approached the problem of present operations 8 with the same philosophy that Dr. Wr:'ght mentioned: that, 9 because these operations in the manufacture of transformers do 10 not require process water, that Pyrarol, which is the G-E 11 trade name for its use of PCB's, theoperations do not 12 involve water, the ^>yranol is used in an anhydrous state. 13 Therefore, we have taken .11 of the steps that we 14 thought were warranted and necessary to keep losses from that 15 operation from getting into drainage systems that would 16 ultimately be discharged to the river. 17 Q. Have you identified the sources of the contamination ` 18 Because apparently there is seme contamination of the effluent 19 despite your best efforts. 20 Have you identified what these sources are? 21 A. You^have to understand that, in the operation of 22 a transformer manufacturing plant, the transformer has to be 23 filled at a particular station. It is done over a deadended 24 sump, with carefully marked special hoses so that there is no
Inc.
25 opportunity for mistaking what you are dealing with. There is
DSW 315113
2690
1 a daily check by an engineer who goes around with a checklist
2 to make sure that all of the hoses are in proper position; that 3 the sump is not full; when it reaches a certain level, it is
4 pumped out.
-
.
5 So, all of these stages of building transformers
6 are monitored anr controlled as carefully as it is humanly
7 possible to do. With a big transformer which may hold a thousanc
8 gallons or more of Pyranol,. the kind of losses that we are
9 observing are in order.of'parts per million of the total amount
10 being used.
11 ft Well, you have stated losses are in the order of
12 parts per million.
13 How are these measured?
14 A. I say, if you measure the total amount that's in
15 the effluent stream. That is the only place where we can
16 measure an actual loss from a plant. Inside the plant, the
17 drains are deadended. The sump is deadended. It is pumped out
18 daily.
19 ft What's done with the residue?
20 A. ' Any W'aste material that is not recoverable for
21 further use is transported to an incineration facility that we
22 have constructed on site. This facility in capable of complete
23 incineration of PCB's, with the only effluent being carbon diox^
24 ide and water.
Inc.
25 So any PCB's that are not recoverable for further
DSW 315114
TEI'
2691
1 use are incinerated on site.
2 Qi Well, you have described what you have done, and
3 you have also described that there are PCB's in the effluent. 4 Is it^your testimony that you don't know how the 5 PCB's get into the effluent?
6 A. In handling any big equipment which must be trans 7 ported from a filling site to a testing site, and back and
8 forth, there is always the possibility of an adventitious loss 9 of a drop here or a half, a drop there. 10 Q. Well, the transformers are sealed after they're 11 filled, are they not? 12 A. Ultimately they are sealed. There are operations 13 that must be carried out in the testing of transformers before 14 the sealing is completed.
15 Q. What is done with a reject or a transformer that
16 has been shown to have a leak?
17 A. The Pyranol that is in the transformer is drained,
18 and, as I said earlier, if it is suitable for reuse it is put
19 back into the production system.
20 If the Pyranol is not suitable for reuse it is
21 incinerated.
22 Q. And the transformer from which the Pyranol was
23 extracted?
.
.
24 A. After it has been freed of its Pyrar.ol it is
Inc.
25 repaired if it can be repaired. These are massive pieces of
DSW 315115
2692
dr-4
1 equipment that are not likely to be discarded if there is any
2 possibiility of repair and sending it back through the produc
3 tion line.
4
, Is Pyranol a trade name for a PCB compound?
a'
.
5 A. It is the trade name under which G-E identifies its
6 transformer fluid.
7 Q. What does Pyranol consist of?
8 A. It consists of the Aroclor 1254, and it consists of
9 trichlorobenzine.
.
10 Qi How much of each?
11 ft. It's approximately a 60 - 40 percent ratio.
12
Q. Have you made any attempt; that is, G-E made any
13 attempt to measure PCB residues in receivving waters from any
14 of its facilities?
15 ft. We have taken occasional samples from the Housa-
16 tonic River, which is the receiving stream for the Pittsfield
17 plant.
18 Qi What levels of PCB were observed in the organisms? 19 A. We have not sampled organisms. We've sampled the
20 river water.
. 21 22
Qt I see. Could you tell me what levels of PCB's were observe 1
23
24
Jercl Reporters, Inc.
25
in the water?
.........
A. The report that I have seen show values in the
vicinity of the outfalls of between one and three parts per
DSW 315116
STLCOPCB4055581
2693
1 billion -- in that range.
\
2 Q. Would this be before or after reasonable mixing
3 had occurred, in your opinion?
4 A. I could: not give you an answer to that# because I
5 have not gotten -- I have not seen a definitive position in
6 the river where this was taken.
7 Ql The sampling was done at only one point?
8 A. No# samplings were made also below the outfall, and
9 at a distance of something between one and six miles-- and-1
10 am not sure of the exact distance at this point, but it could
11 be as small as one mile below the outfall--no detectable
12 PCB*s.
13 Qi VJhat was the analytical technique used?
14 A. Essentially, the technique recommended by EPA:
15 the extraction of the water with hexane, concentration of the
16 hexane extract, and then injection of a sample of that extract
17 into a gas chromatograph where calibration is done against
18 standard samples of PCB's.
19 Q. The limit of detection of that technique is only
20 one part per billion, isn't it?
121 A. That has been our experience.
22 & So that if there were smaller quantities, you'd
23 not expect to be able to measure them, isn't that ,right?
24 A. We would have no reliance on numbers that would
Inc.
25 show up in calculation from th~ chromatogram as being beiev
DSW 315117
STLCOPCB4055582
2694
1 one part per billion on an industrial type of sample. 2 Q, Have you measured the PCB levels in the sediments
3 of the river?
,
4
ft. May I. check? ' v
.>
'
5 & Certainly. Use any document you like.
6 ft. Yes.
t
7 Q. Could you describe where the samples were taken
8 and what levels were found?
9 ft. At the same sites at which this one-to-three part
10 per billion range in the water, the sediments were 130 and
11 1,300 parts per million.
'
12 Ci Were samples taken at the second point, the one
13 six miles downstream? ; ..........'
14 A In areas where it was not detectable in the water,
15 the sediments were 30 to 60 parts per million.
16 ;
Q.
Were these identifiable as 1254 or 1260?
17 A I do not have that information.
18 Ci Do you know when the samples were taken?
19 A October of 1971.
20 Q. Therefore it would all be 1260, wouldn't it?
2-1 A It would probably all be 1260. Correct.
22 Ci Have the control measures which, you have been --
23 let me rephrase that.
24 You referred to control measures to minimize the
Inc.
25 discharge of PCB's.
DSW 315118
2695
1 How long have those control measures been in effect?
2 A. It is an evolving program. For example, the
3 incinerator is a relatively new installation, within the past
4 two years. The diking around the unloading area, or consoli
5 dation of filling stations to reduce the number of areas in
6 which Pyranol is handled at the plant -- all of these have
7 been steps that have been taken over a period during the last
8 four years, let us say.
9 Ql Do you have any data on the levels of PCB's in the
10 effluent on or about October, 1971, when the samples were
11 taken in the river?
12 A.
I do not.
13 Q. Were any observations made of the aquatic popula
14 tion in the river at that time?
15 A. We have done nothing with the aquaticpopulation.
16 ^ Q. Now, in the Rome plant have measurements been made
17 of PCB discharges?
18 A. Yes.
19 Qi Would you give me the data in the same fashion as
20 you gave me the data for the Pittsfield plant?
21 A. I don't have it in that same form, but our engi
22 neers, who have taken samples and made the appropriate calcu
23 lations from that have estimated that the current discharge
24 is on the order of one pound per day.
Inc.
25 Qi Which Aroclor is this?
DSW 315119
STLCOPCB4055584
2696
81
A. There, too,. 1254 is the Aroclor that is used.. .
2 Qi Could you describe the control measures currently
3 in effect at the Rome plant.in order to minimise discharges
4 of PCB's?
*
5 A. The same program of control measures is being
6 installed at that plant, but it is not as far along as at
7 Pittsfield.
'
8 But basically, the program is the same; that is,
9 containment of the PCB's in the production area.
10 Ql To avoid repetitive questioning, let me ask you
11 a general question.
12 Have measurements been made of residues in biota
13 for any of the facilities operated by G-E?
14 A. We have made no measurements of biota for any
15 facility of the General Electric Company.
16 Qi Now, for the Rome facility, have any more measure
17 ments been made of PCB levels in the -- I believe you stated
. 18 it was the Coosa and the Oostanaula River.
. 19
A. The Oostanaula River.
- 20
I do not believe that my data on those plants
2J indicate any analyses of rivers, but are basically the data
22 of the plant discharge. I do not know-of any numbers per
23 taining to the rivers themselves.
24
-ral Reporters, Inc.
25
Qi Could you give me for the Hudson Falls plant the
levels of PCB's discharged?
,, DSW 315120
............
.............................. ....... ...........
STLCOPCB4055585
2697
1 A. These outfalls from the Hudson Falls plant, which
2 are incorporated now in the permit application, in total come
3 to two facilities, is on the order of 25 to 30 pounds per day.
4
Ql 25 to 30?
*
5 A. Yes.
6 MR. ECKERT: Your Honor, I think I have a good
7 deal more questioning for Dr. Simons.
8 Would it be appropriate to break for lunch at this
9 time?
10 JUDGE SWEENEY: All right. We'll recess until
11 one o'clock.
-.
12 (Whereupon, at 12:00 noon, the hearing in the
13 above-entitled matter recessed, to reconvene at 1:00
14
p.ra. the same day.)
.
15
16
17
18
19
20
21
22
23
24
Inc.
25 DSW 315121
STLCOPCB40555
2698
1 AFTERNOON SESSION
2'
(1:00 p.m.)
3 Whereupon,
4 EDWARD L. SIMONS
5 resumed the stand and, having been previously duly sworn,
6 was examined and testified further as follows:
7 CROSS-EXAMINATION (Continued)
8 BY MR. ECKERT:
9 ,Q Dr. Simons, you testified that the combined
10 effluent from the Hudson Falls and the Fort Edward plants 11 is 25 to 30 pounds a day. Is that correct?
12 A Mr. Eckert, I wonder if I might have your in
13 dulgence, before ansv;ering that specific question, to add
14 some clarification to the answer that I gave you with regard
15 to Pittsfield, because I think they're germane to the kind
16 of answer I would have to give to your question. `
17 Q Well, perhaps so.
18 A You asked basically two questions concerning the
19 Pittsfield operation. One was the number of pounds per day
20 that were being discharged and secondly, could we identify
21 the sources of that.
.
22 I gave you a number of .1 pound per day of 1254
23 from current production. I think it's appropriate to indi
24 cate the way in vrhich that number was arrived at.
Inc.
25 We have two outfalls from the PCB plant where
DSW 315122
................
STLCOPCB4055587
2699
1 effluent has been found to contain PCB's. During 1973, each 2 one of these outfalls was sampled once a week for 45 weeks 3 and each sample was then analysed both for 1254 and for 1260, 4 As has been pointed out both in our testimony and 5 in the testimony of Monsanto, sampling of industrial wastes 6 for a material like PCB's is a difficult process whose re7 produceability is quite poor. The value of .1 pound per day 8 was calculated by taking the average concentration for all 9 45 samples during 1973 and multiplying it by the average 10 volume of discharge from those two outfalls. So there was
n no single number that was measured over a period of con
12 tinuous measurement for one day and we collected .1 pound. 13 These were all calculated from single grab sa-mples 14 once a week for each of 45 weeks. 15 At the same time that I give you an average I have 16 to also indicate that there were certain samples which gave 17 values which were higher than that average and if we took 18 the single highest value of each of these 90 samples and 19 combined that with the effluent flow we would come up with a 20 value of .8 pound per day as a maximum figure. 21 So there's a v/ide range, with occasional excursions 22 as high as .8 pound per day on the 1254 and as high as .4 or 23 .5 pounds per day on the 1260. 24 That puts, I think, the analysis into perspective.
Inc.
25 Tt is not a matter of collecting and weighing an actual .1
DSW 315123
STLCOPCB4055588
2700
1 pound. These are all calculated numbers. The actual parts
2 per billion in the individual samples were usually in the
3 range from one to ten parts per billion.
4 When you get down to analyses that are as close >
5 as that to the sensitivity of the noshed, the actual value
6 can become distorted by a very smalD amount of any impurity
7 that might get in during the actual handling of the sample.
8 But this is the best number we have and it's the
9 number I gave you, but I thought it would require that addi
10 tional clarification as to how it vr.is arrived at.
n Nov; let's come back and answer in a little bit
12 more detail the question of where t:\is .1 pound might come .
13 from.
. . . ..
14 To put that .1 pound per day in a possibly more
15 illustrative format that would correspond to a small jigger
16 of whiskey, about one ounce, so we are not talking about a
.17 major spill. This is a relatively small volume of liquid.
18 As I said, our philosophy was that for current
19 production ve should try to modify cur manufacturing opera
20 tion to reduce the possibility of any loss of PCB's. I
21 probably am-- A year ago when I officially assumed my present
22 responsibilities -- a little over a year ago ~ I was proba
23 bly in the same position as you in being unable really to
24 visualise what these controls meant in a practical term, but
. Inc.
25 I have made it a point to visit on two occasions the
DSW 315124
STLCOPCB4055589
2701
1 Pittsfield plant and examine in .great detail the individual 2 handling and manufacturing steps from the arrival of the tank 3 car through the finished transformer, and I have quite a 4 different appreciation than I did before of what a loss of 5 one ounce can mean. 6 Remember, we are not manufacturing at this plant, 7 only Pyranol-filled transformers. We also manufacture -- and 8 the major part of our production is oil-filled transformers; 9 Pyranol-filled transformers are not the major product at 10 Pittsfield. 11 We have attempted to reduce to a minimum the number 12 of places in the plant where we handle the Pyranol so that 13 doesn't get spread out and handled everywhere. The filling 14 is all done in a fixed station and I've explained that earlier, 15 but after the Pyranol has been added to the transformer tank 16 it must then go by conveyor to certain highly specialized 17 test stations which have to go through a series of electrical, 18 tests to be sure, before the transformer is completely sealed, 19 that it has been filled properly, that there are no air 20 spaces and other things that affect its electrical performance. 21 This is a transfer operation during which the 22 transformer is not sealed. It then may have to go back for 23 further filling, which is another transfer operation. It 24 eventually has to get a final topping off, all of this before
Inc.
25 the sealing.
DSW 315125
2702
1 At any one of the stages when you consider that
2 some of these transformers will hold as much as 1500 gallons,
3 even the loss of a fraction of an ounce on a workman's shoes,
4 on his hands, these are things which I think even the most
A
5 elaborate containment system in a massive manufacturing
6 operation like that cannot guard completely against.
7 To put this again in terms that might be a little
8 more illustrative, when it's available we all use gasoline
9 to power our cars, and you know what happens when you use
10 up -- when the attendant or at the self-service station,
11 you yourself use a hose to fill up your tank. Your tank may
12 hold 20 or 25 gallons. There are varying degrees of gasoline
13 lost during that filling operation. I doubt that-- It is
14 seldom as low as a drop or so? more often it's much more than
15 that.
16 Again I want to indicate that we are applying very
17 strict standards to the filling of this, but these are big
18 equipments. It is inevitable that there is going to be
19 something that gets on the lip, something that gets on the
20 conveyor, and these are things that we try to keep to a
21 minimum.
v,
22 ' The goal is zero containment but in a plant as
23 big and as old as this, and with workers around there who
24 have to handle this in order to get it out to the test
Inc.
25 station, a loss of something of the order of one ounce during
DSW 315126
....... ......
........
STLCOPCB4055591
2703 1 the day's operations is, we think, a very creditable per 2 formance. I don't know of any other really heavy manufactur 3 ing operation which handles fluids in which that kind of 4 level of control is displayed. 5 Now I think I can come to answer your question 6 about Hudson Falls. 7 One minor correction. I said those numbers I gave 8 you were from our permit applicati: *i. I meant to say these 9 are the numbers that appear in the draft permit for that 10 plant v;hich we have received from F?A Region 2, which indicate 11 certain initial effluent limitatior 3 to be placed upon this
<. 12 plant. 13 And by the way, as you correctly said, the Hudson 14 Falls and Fort Edward are so close together they are being 15 considered as a single plant for purposes of this permit, so 16 that the number given here was for the outfall that corres 17 ponds to the Hudson Falls plant, ten pounds per day as the 18 daily average as the initial effluent limitation and for the 19 discharge from the Fort Edward plant, the initial discharge 20 limitation is 20 pounds per day. That's where the 30 came 21 from, but again these are daily averages. 22 And once again I must refer back to -- I must refer 23 to sampling procedures. We have not taken samples as fre 24 quently at Hudson Falls as at Pittsfield. They are more
Inc.
25 likely at once-a-nonth intervals so we have about ten of
" DSW 315127
...................
.............. STLCOPCB4055592
2704
1 those rather than 45. 2 These numbers again represent the average pounds . 3 per day as calculated from a parts per billion analysis and 4 a flow rate.
5 There have been excursions which, in proportion, 6 are about the same as we've had at Pittsfield. That is at 7 Pittsfield I said we had an average of .1 pound per day and 8 a maximum of .8. We have seen days when, if we took the 9 analysis at its face value and calculated it through with the 10 flew rate, we would end up with 90 pounds of discharge. 11 This reflects some of the difficulties in sampling. 12 It may reflect accidental discharges in the plant. We just 13 do not know, but I think that's the way in which these numbers 14 have to be viewed. 15 An average number over a ten-month period and with 16 maximum excursions can be as high as eight times or nine 17 times as high as that. 18 Now I think that would represent the clarification 19 I would give, up to this point, and I would await your further 20 questions. 21 Q Let me see if I understand this correctly. 22 The 10- and 20-pound a day figures which appear 23 on the draft permit, are those the same as the numbers which 24 you arrived at by -calculation from the effluent concentration
Inc.
25 and effluent flows?
.......................................................... ........ .....................
DSW 315128
I I
STLCOPCB4055593
2705
1 A These are essentially the numbers that we arrived
2 at from these measurements of grab samples over a ten-month
3 period, averaged them out, and made the computation from the
4 average flow rate through those discharges.
>
5 Q What was the range of concentrations which were
6 observed?
7 A The concentrations observed at the-- I only have
8 the average^figure here. I do not have the range and the
9 concentrations.
10 From the Hudson Falls, 350 parts per billion, and
11 Fort Edward, 4,000 parts per billion, and it's these numbers--
12 Q * I'm sorry, atFortEdward what was it?
13 A 4,000.
14 .
It's these numbers which combined with the
15 flow rates from' those installations were used to calculate
16 the average pounds per day. '
17 Q Has GE attempted to measure the concentration of
18 PCB's in the Hudson River below the plants?
19 A No. 20 Q Are the PCB's discharged from the Fort Edward
21 and Hudson Falls plants all 1254?
`
.
22 A No. There areseveral importantdistinctions
23 between the Operations at these two plants which manufacture
24 capacitors and the two plants that manufacture transformers.
Inc.
25 * To answer the first part of your question, it is
DSW 315129
2706
1 not 1254. The capacitor grade Aroclor 1016 is used exclu 2 sively at the capacitor plants. And I would say that that 3 probably accounts for 95 percent of the-- 95 percent of 4 the production is with 1016 Aroclor.
5 Q What is the five percent? 6 A I don't know. There may be a few specialised oil 7 transformers, mineral oil for certain specialized uses, but
8 those are not a-- The large bulk of the production-- 9 HR. RICREL: We've been informed it is mineral oil.
10 THE WITNESS: That's what I said, mineral oil.
11 BY MR. ECKERT:
12 Q So far as you know then, no PCB other than Aroclor
13 1016 is used at Fort Edvrard and Hudson Falls. Is that right?
14 A At present that is so. We formerly had used the
15 1242 before 1016 was developed, 1016 is a relatively recent
16 development by the Monsanto Company as a special grade for
17 capacitors from which the higher boiling homologs have been
18 distilled out.
19 In other words, we believe on the basis of the
20 evidence from Monsanto that the 1916 is the most highly bio
21 degradable of the commercially used A.roclors and that is th<
22 reason we switched to that for capacitors.
23
But there is also another very significant dis-
j
i
!
24 tinction between the use of PCB's in capacitors and in
Inc.
25
DSW 315130
STLCOPCB4055595
2707 1 transformers. Transformers are, as I mentioned, relatively
2 large units, as big as 1500 gallons capacity, and they are
3 made in relatively small quantities. I guess you could say
4 in the tens of units per day kind of range.
5 Being a big tank, you can put a hose into it and
6 fill it directly that way.
.
7 On the other hand, capacitors are much smaller
8 units and we're talking here about an operation in which we
9 have to fill millions of small units with PCB's, and by
10 "small units" I'm talking about things that might be the size
11 of a pack of cigarettes or less, as small as that.
12 .
Obviously, these kind of units are not filled by
13 a hose. They are filled in bulk by putting them in a tray
14 which is sent into a vacuum oven. The whole thing is evacuated
15 and then filled by filling that container with PCB's so that
16 they are sucked into the evacuated cans.
17 That means, therefore, that when you take these
18 out of that for handling there are not only PCB's inside the
19 can but on the outside, and this must be disposed of, so that
20 all of the handling problems, the units and all, increase the
21 probability of losses by adventitious handling.
22 And than there's a third important distinction
23 which was brought out in Dr. Wright's testimony, that for the
24 electrical industry as a whole, there are approximately three Inc.
25 times as much -- three times the amount of pyranol or PCB's
DSW 315131
STLCOPCB4055596
ebll
2708 used in the manufacture of capacitors total as are used in the
2 manufacture of transformers, so we're dealing with a total .
j
3 amount of material that is much larger and it is distributed
4 over a tremendously large number of very tiny units which have
5 to be filled.
|
6 So there's quite a major difference, all of which -- j
7 the processing of all of which accounts for the major dis
8 crepancy or difference between the discharge in the capacitor
9 plant and that for a transformer plant.
10 Q Why are PCB's used in capacitors?
`
11 A The basic reason for the use in capacitors is to
12 improve reliability and performance characteristics in a
i
13 smaller volume of total product.
;
14 They also confer the safety factor of the non
15 flammability of PCB's.
16 Q Aren't there other diaelectrics that could be used,
17 other than liquid diaelectrics? For example, hasn't Mylar
18 been used in capacitor manufacture for example?
19 A There are certain capacitors-- You have to recog
20 nize that there are basically three types of capacitors and
21 I want to put in one warning here. I am not an electrical
22 engineer so that I cannot speak with the same degree of
23 confidence as I have been speaking on the previous ones.
24
ederal Reporters, Inc.
25
But it is my understanding and if it is permissible. Dr. Pozefsky from our Capacitor Department has my permission
DSW 315132 STLCOPCB4055597
1 to correct me if I make any misstatements.
2709
2 There are what we would call electronic-type capa
3 citors which are basically -- many of which are a dry type
4 and are manufactured without any PCB's at all and have this
5 kind of aluminum and plastic film.
6 Then there are the kind which are manufactured at
7 our Hudson Falls and Fort Edward-- Hudson Falls is basically
8 the power transformers which are used in the electrical
9 utility industry and for these there is no substitute.for a
10 liquid-filled transformer or capacitor.
11 The only place where there has been some experimental
12 work that indicates a partial substitution to, shall we say,
13 a dry type which doesn't use any liquid is in some of the
14 industrial type capacitors of a kind that are used in the
15 ballast for fluorescent lamp fixtures and air conditioners
16 and so on, but I believe that the technology for that is not
17 anywhere near the level where it can be considered as a short-
18 range alternative to PCB * s.
19 It would obviously facilitate greatly the produc
20 tion if we didn't have to handle liquids.
21 Q Why is there no substitute for liquid-filled capa
22 citors in power applications?
23 A I can't give you a specific answer technically to
24 that. It has something to do with the requirements that
Inc,
25 these capacitors -- the kind of currents that these have to
. DSW 315133
STLCOPCB4055598
eb!3
2710 carry. But I would have to defer an answer on that, unless
2 you want to get clarification from Dr. Pozefsky on that ques . 3 tion.
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
-terol Reporters, Inc.
25
DSW 315134
STLCOPCB4055599
2711
1 Ql Well, perhaps we can pass over that for the time
2 being.
.
3*
Have you attempted to measure the PCB levels in
4 the sediments Qfcserved in the Hudson River?
5 A. There have been no measurements made by us of the
6 Hudson River.
'
7 Ql Have the workers themselves been monitored? For
8 example, have blood samples been taken and measured for PCB
9 content?
.
' : **
10 A. Before coming down here I checked with the medical
11 director of our Pittsfield plant, who is aware of -- who can
12 speak,.in terms of direct experience at Pittsfield and is
13 aware of the situation at the other plants that use PCB's,
14 because in our testimony we had indicated that the only
15 medical effects that had been reported during the four decades
16 that we were in this business have been occasional cases of
17 chloracne or other minor skin irritations of a non-chronic
.18 nature which disappeared upon the transfer of the employee
19 to some other operation.
20 _?
I asked the medical director if that statement is
21 still valid today; he assures me it is, and that that is the
22 extent of the medical problems that we have encountered among
23 the employees exposed to PCB's.
24 Inc. Qt Well, that doesn't quite answer my question. 25
I asked if their blood levels have been monitored
DSW 315135
.................. .................................................
STLCOPCB4055600
2712
1 for PCB's.
2 A. No, not to my knowledge.
.
3 & Now, in specific reference to the medical data,
4 I don't have it in your testimony -- yes, it's on page 6 --
>
5 the statement here reads that:
.
6 ''Medical records show that over a nearly
7 40-year period, the only adverse health effects
8 experienced by U.S. workers exposed to PCB's," --
9 etc. ---"have been limited to occasional cases of non
10
chronic chloracne or other temporary skin lesions
j
11 or irritations."
' 12 A. Yes.
......
I
I
j
13 ft Now, I assume that over a 40-year period some of j
14 the workers died, did- they not?
j
15
A.' ` That's a reasonable assumption.
": -
j
16 Q. Some of them might have gotten cancer; isn't that i
17 correct?
'v-'r'
j
18 A. MR. RICHEL: I would like to object atthis point.
19 The man is having visions of vinyl chloride and has intro
20 duced no basis into the record for this kind of excursion.
* V*
21 : -
" MR. ECKERT: Well, it seems to me that the aasis
;
22 for the record is the statement here that the only adverse
23 hea' `lth effects experienced b*y U.S. workers exposed to PCB's 24 was non-chronic chloracne, and I'm trying to get at whether
Inc
25 or not anyone bothered to find out whether these workers might
DSW 315136
~
STLCOPCB4055601
j v
- : 2713
1 have had a higher incidence of cancer than the --
2 MR. RICHEL: I think the witness has made it clear
3 that all inspection, all we did --and we're not trying to
4 make anything more of it -- all that we did was react to
A`
5 requests made by employees, and no further tests, no consider
6 tions of cancer, no considerations of -- no blood tests;
7 nothing other than what we have said.
8 But if you further lay the foundwork, if all you
A
9 further do is leave innuendo, then I think this is grossly
10 improper.
.
11 MR. ECKERT: I'm certainly not leaving any innu
12 endo .
.
13
BY MR. ECKERT:
<
14 ft Is that your testimony; has Mr. Richel accurately
15 stated your testimony?
16 A. These medical records are based upon the examina
17 tion of workers who have come to the medical office of the
18 company with a complaint. And these have been examined, and
19 when they have been convinced that these complaints which
20 were brought to the attention of the medical officials were
21 a result of exposure to PCB's the worker has been transferred
22 to other operations, and the complaint has disappeared.
23 MR. ECKERT: That's all I wanted to establish.
24
Thank you.
*
Inc.
25 BY MR. ECKERT:
DSW 315137
STLCOPCB4055602
2714
1 Qt Getting back to the Hudson Falls and Fort Edwards
2 plants; what is the total quantity of PCB's used at these
3 plants per year?
,.
4 A. I've been advised by the Counsel for the affected
A
"'
'
5 products departments that they consider the data on total
6 usage of product material as material that would be useful
7 to competitors and should be considered as proprietary infor
8 mation.
.
9 MR. ECKERT: Is it your position, Mr. Richel, that
10 this information relates to trade secrets, processes, or
11 methods entitled to protection as trade secrets?
12 MR. RICHEL: Apparently that's the contention of
13 the Counsel for the affected department, and that's why Dr.
14 Simons indicated as he did. I have no reason to support or
15 reject that contention.
16 MR. ECKERT: In other words, you don't know?
17 MR. RICHEL: That's correct.
18 I do know that it's significantly different from
19 effluent data, and anything other than effluent data is giver 20 the opportunity for certain privileges under the Water Act
21 Amendments of '72. ,
.
22 MR. ECKERT: That's not quite correct.
23 It isn't the only information subject to protectic
24 methods or processes entitled to protection as trade secrets
Inc.
25 MR. RICHEL: That's correct, DSW 315138
....................
...................................STLCOPCB4055603
2715
12 data. 3 4 record.
And that itself relates to other than effluent *-
ME. ECKERT: Well, we can dispose of this off the
5 BY MR. ECKERT:* 6 fit I wonder if you would describe the sources, if you
7 have_identified them, of effluent contamination at the Hudson
8 Falls and Fort Edwards plants? 9 A There is one significant source of contamination
10 from the Fort Edward plant, which results from one of these
11 basic differences that I mentioned to you between manufacture
12 of capacitor and of transformers.
13 The transformer cases, after they are filled, as
14 I stated, have PCB's on the outside just because of the way
15 in which these tiny cases have been filled. That layer --
16 even after draining there is still a residual layer of PCB on
17 the case, and it had been the past practice to remove them
18 through a washing operation with an aqueous-based detergent;
19 and that has been identified as a major source of water con
20 tamination.
.
21 There is one case where water was actually -- the
22 only case where water was actually used in the processing of
23 the equipment itself.
24 Q. Excuse me.
`
tnc.
25 Are you referring to transformers or capacitors?
SW 315139
.................
.................................................................................STLCOPCB4055604
271C
1 A Capacitors.
2 The transformers, that have to be -- because of .
3 their size -- filled by this vacuum inpregnation technique,
4 which means the entire capacitor is essentially immersed in > 'j
5 a sea of PCB's, and when the tray containing these capacitors
6 is taken out the PCB's are on the outside as well as on the
7 inside of these little capacitor cans.
8
The vast majority of that PCB is allowed to be
j
9 drained off and be reused, but there is always a residual
10 film that remains on the can which must be removed before the
11 can can be sent out as a finished product.
.
12 .
And the standard practice had been to remove that
13 by a washing with an aqueous solution. That would represent the j
* .i
14 major source of contamination of effluent from the Fort Edward
15 plant.
16 And the management and the operations at Fort Edwar< ;
-j
17 have recognized this and have now begun to investigate and are
18 prepared to install alternate means of removing that PCB from 19 the outside of the cans so that that single -- that largest 20 single source of contamination is removed.
21 Q. Now, you say you are prepared to install; but is 22 the water wash still being used at the present time?
23 A It is. 24 Ql That would account for the Fort Edwards plant.
Inc
25 How about the Hudson Falls plant?
DSW 315140 ' STLCOPCB4055605
2717
1 A. The number that I have given for both plants --
2 or the numbers that I have given for both plants represent
3 a total PCB concentration. It is not quite as easy to make
4 the differentiation between current and residual in the
5 capacitor manufacturing operation as it is in the transformer
6 because 1016 and 1242 are much more closely alike than are
'
7 1254 and 1260. .
.
i
8 So --
.!
9
What's being used at Hudson Falls?
,I
10 I.-
1016 is being used now, prior to the development
11 of 1016 by Monsanto 1242 is used.
j
12
1242 and 1016 have very close to the same total
i
13 chlorine content. The major difference has been the removal |
14 of some of the higher-boiling homologues present in 1242
i
15 that are not present in 1016.
;
16
It is a more difficult analytical procedure to
j
17 try to differentiate between 1016 and 1242 in a chromatogram j.
18 of a mixture of these two. It is a much easier job to dif
19 ferentiate as we do at Pittsfield between 1254 and 1260. 20 And so at Pittsfield we can look at a chromatogran
21 and say, "Yes, this much is caused by residuals, and this
22 much by current production."
23 It is not as simple an analytical job to do that
24 at Hudson Falls, and therefore a large amount of that could
Inc.
25 very well be from our residuals of production that has been
DSW 315141
............
.......................
STLCOPCB4055606
`.
-2718
1 going on there since the early '50s, before any controls at
2 all5 were instituted.
`!
3 ` ' ' So the only clearly defined process operation as
4 sociated with a loss of PCB's directly to the water is that
5 detergent wash'at Fort Edward. The other losses we cahnot 6 pinpoint and say how much is from.a particular current operati 7 and how much is from residuals from decades past. . .... ,,
8 fit Now, the Fort Edwards plant: what treatment is
9 given to the wash water from the capacitors?
..
10 A. None.
. .. : .
11
;\
And rather than institute treatment, there is a
12 process -- I would have to qualify that.
-
13 There are three stages in this: there is washing
14 and there is rinsing. The wash water itself is internally
15 recycled. The only thing that goes directly to the'river
......
.. ; -..i '..
16 untreated is the final rinse, which itself contains only a
17 trace amount of the detergent so that the bulk of the PCB`s
18 that are removed by this washing operation do not leave* the
19 plant; they are retained internally and ultimately disposed
20 of through incineration the way other waste PCB's are.' It's
21 onlyJthe final rinsing stage that goes untreated to the river
22 `' : And it is, in our opinion, a more satisfactory
23 resolution of that problem to change the process rather than
24 to try to remove the PCB's from the rinse water before dis
Inc.
25 charge to the river.
..
DSW 315142
....... .........................
STLCOPCB4055607
2719 1 ft When a transformer is installed, does it ever
2 need to have its diaelectric replenished?
'
3 A. There are times when that has to be done.
4 ft What is the cause of that?
5 A. I'm afraid I can't, give you a specific technical
6 answer to that question..
7 ft Well, would you infer, if it has to be replenished,
8 that some is being lost through leakage?
._ .
9 , A.
It could be some being lost through leakage; it
10 could also be there may be -- remember that a transformer
11 is not just a big tank filled only with PCB's. There is a
12 very complex combination of wire with insulation, other kinds
13 of materials in there. There's whole guts of very complicated
t.
14 electrical equipment.
15 Some of that must be thoroughly impregnated with
16 the PCB at the time of the manufacture if it is to function
17 properly. There may be other parts where that is not critical.
18 And over a period of use, it's possible -- and 19 again I'm speaking only from conjecture since I do not 20 know enough about the details of that -- it is possible that
21 PCB's impregnate parts of the transformer where they don't
22 normally become or are not normally needed, and therefore
23 reduce the level of free diaelectric.
24 So that's a second possibility that I throw out
Inc.
25 without the same degree of assurance that I have spoken with
DSW 315143
STLCOPCB405560
. 2720
1 on other matters.
2 ft Do transformers ever need repair on the site on
3 which they are installed?
4 A. Usually -- and again I will speak only -- well,
5 there may be certain repairs that can be done on the site. 6 I don't know the nature of all the ills and ailments that a
7 transformer can fall heir to during its thirty years of
8 expected life.
'
9 So there may be some malfunctions that can be
j
I
;
10 repaired onsite. There are others that require more extensive
11 repair work.
12
& When they need that more extensive repair work,
j
13 are they shipped back to G.E. for work?
.
14 A. There are service shops that the General Electric
15 Company and other companies maintain at which transformers 16 can be repaired, along with lots of other heavy equipment; 17 they are not exclusively transformer repair shops.
i
'
18
ft
Does G.E. manufacture transformers or motors for
i
19 electric trains -- I mean, electric locomotives?
20 A. ` If you're talking about the trains that operate
21 on electrified lines --
j
.
i
22
ft
Either those or for diesel electric locomotives.
!
23 A. Diesel electric locomotives, as I understand it,
24 do not need transformers. They have their own generators
fnc.
25 and generate electricity there.
DSW 315144
.............
.......
............ STLCOPCB4055609
2721 .I 1 The main use of transformers in railroad transporta 2 tion is on the electrified lines, where the electricity is 3 taken from a third rail or from an overhead line. 4 . And yes, we do manufacture the transformers that 5 are mounted underneath the cars of such electrified railroads. 6 ft These are like all other transformers in terms 7 of their susceptibility to leakage, are they not? 8 A I assume that they are. 9 They are designed Of a size to fit under the rail 10 road car, but basically the transformer is the same kind of 11 instrument. It's made and welded shut, and so on, and I 12 assume that damage that could occur to one can occur to 13 another. 14 ft When you receive PCB's from the manufacturer, does 15 it come in in tank cars? 16 A Yes. 17 ft How is it offloaded from the tank cars? 18 A Basically by the same kind of procedure that 19 Dr. Wright described. It is pumped out from there into ap 20 propriate storage vessels, and from there piped to the areas 21 in the plant where it's used. 22 ft Is it unloaded under cover from the elements? 23 A This varies from plant to plant. 24 At our Pittsfield plant that station is covered.
Inc.
25 It's a new station, relatively new. It was built with all the
DSW 315145
.................
.......................................................
STLCOPCB4055610
2722
1 appropriate qiking and sumping and so on, and that is unloaded
2 under a cover.
j
3 I would point out, however, that these are -- these j
4 unloading operations are basically infrequent kind of things.
5 You don't get this kind of a shipment in every day. This is
6 not a daily operation, and these are carefully monitored as
7 the transfer takes place.
I
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Inc.
25 DSW 315146
STLCOPCB4055611
2723
1 Qi What precautions are taken to avoid spills during
2 the unloading operation?
-
3 A. The unloading operation, as I have seen it at
4 Pittsfield, that I can speak of from direct observation, is
5 carried out in an area which is diked and which has deadend 6 sumps, so that anything which does drip or spill during the
.
7 transfer operation does not get out of that area, is retained !
8 by the dike, goes to the sumps, and is pumped for recovery or | 9 incineration.
10 Q. Are you familiar with the operations;at Fort
11 Edwards and Hudson Falls?
'
12 A The tank car there is on an open siding adjacent
13 to the building.
j
14 Qi Is the area around the tank car unloading platform j
15 diked?
16
A. The diking is essentially accomplished by the
!
17 building itself, whereas-at ..Pittsfield there's an entirely
;
18 separate area. There was no building there, so a separate
19 dike wall was put up.
;
20 Q. Are there deadend sumps at the Hudson facility?
21 A Part of the program that's being undertaken there
22 now is to identify all of the drains accessible to PCB's which !
23 could lead into the aqueous discharge, and to block those off.:!
24 This was an old plant. We took it over in about
Inc.
25 1952. I don't know what the age is, but it was not originally
DSW 315147
............. ..............
STLQQPQB4Q55612
2724
1 built as a plant. It was bought as an existing building, and
2 as we go along through that plant, we find other areas that
3 need attention. And there's a systematic review of all the
4 drains, gutters, and so forth to plug up all the possible
5 avenues of escape of PCB's.
6
Q.
Do you use PCB's in any other process than the
.
7 manufacture of capacitors and transformers at ar.y of your
8 facilities? 9 A No. 10 The only manufacturing operations that use PCB's
\
i
j
11 are transformer and capacitor manufacturing,
'
12 Q. Are the PCD' s treated or conditioned in any way
13 prior to putting them into the capacitorsortransformers? '
14 A Yes.
.
15 Q. What's done?
' `
| I j
i
16 A There isbasically a filtrationtype ofprocess to j
.i
17 remove impurities that may have been picked up during transit '
18 or from long storage in the tank car, and so forth.
19 Basically a filtering process through a porous bed.
20 Qi Is the filter, the filtering material disposed of
21 by incineration?
j
22 A Our incinerator can handle material, yes.
23 fr Well, is it handled at --
24 A Yes. I believe it is also disposed of there. Yes.
Inc.
25 Because this is a combustible bed.
....... .............
................... ........
DSW 315148 ...... STLCOPCB4055613
2725
1 Q. Do you apply heat and --
.
2 A Excuse me, when I'm talking about this. I'm refer
3 ring to the Pittsfield- plant. It's the only plant that has 4 its own incinerator.
5 Q. What is done at Fort.Edwards and Hudson Falls'with 6 the filter material.
7 A. Combustible wastes are cent to an outside scavenger
8 who has incineration facilities. 9 Q. And noncombustible wastes?
10 A They are like scrap capacitors and things like that,
11 which can't be burned.
12 These are disposed of in an appropriately operated
13 landfill, an approved landfill.
14 Qi Are the PCB's heated or vacuum treated to demoist-
15 urize them before putting them into the capacitors and trans 16 formers?
17 A I don't know.
18 First, for the transformers, I don't know.
19 In the capacitors, the operation of filling is at
20 a higher temperature than it is in the case of transformers,
21 but I do; not know that it is a separate heating operation.
22 Q. Has any measurement been made of the evaporative
23 losses of PCB's during this process?
24 A I've been told by the plant people that they have
Inc.
25 had measurements made of the concentrations of FCB vapors in
DSW 315149
STLCOPCB405561
2726
1 the work area, and it is my understanding that these are below
2 the threshold limit values established under the Occupational 3 Safety and Health Act.
4 0 Is water employed for equipment or floor cleaning
5 in the Hudson Falls or Fort Edwards, plants? >
6 A. Water employed for floor cleaning?
.
7 fit Floor cleaning, and for equipment cleaning. You
8 know, when they talked about capacitor wash -- 9 A. Oh, cleaning. No. If there are any spills, for
10 example, that occur on the floor, they are -- this commercial
n absorbent material is put over them and that is then swept up
12 and sent out for incineration. It is not washed.
13 '
ft
If there is no spill, is the floor washed under
14 ordinary circumstances? .
*
15 A. No.
. 16 ft The floor isnever washed?
I
17 A. Never.
18 (Shakingheadnegatively.)
19 ft Do the workers wear any type of protective clothing'
20 A. We have seen no need for that. The usual protec
21 tive clothing that an employee in manufacturing may wear;
22 coveralls, and things of that sort. But nothing that's . i
23 specificallydesigned as protection for the particular mater
24 ial they're handling.
Inc.
'
.
*'
'. ''
i :!
25 ft What is the volume of effluent discharge from the
DSW 315150
STLCOPCB4055615
2727
1 combined Hudson Falls and Fort Edwards outfalls? 2 A Approximately 2.6 million gallons per day. 3 Qt Can you break that down as to -- 4 A Approximately half a million gallons per day from 5 Fort Edwards, -2.1 million gallons per day from Hudson Falls. 6 {X Have you monitored the various waste streams within 7 the plant to see which one contained and which ones did not 8 contain PCB's? 9 A Well, we don't really have waste streams in the 10 plant, in the sense that, with the one exception of this 11 final rinse in the washing operation at Fort Edward, there is 12 no process water used in the manufacture of capacitors or 13 transformers. 14 fr But there are other process waters used, are there 15 not? 16 A The bulk of the water is essentially for noncontact 17 cooling. 18 Q. Has the noncontact cooling water been monitored for 19 PCB levels? 20 A As I say, these discharges that we speak of, where 21 we analyze grab samples, the bulk of that water is of a cool 22 ing water nature, and we find PCB's in them. 23 Q. . But that's after it has been mixed with the capaci 24 tor wash or capacitor rinse water, is it not?
Inc.
25 A No, I'm talking here -- let's say the case of the
0S\N 315151
..............
....... STLCOPCB4055616
2728
1 permit composed for the Fort Edward-Hudson Falls, there are
2 altogether four separately defined outfalls.
3 One of these is the outfall to which the rinse
4 water is directed. Of the other three, only one has been
'> 5 shown on analysis to contain PCB's, and that's the one which
6 has this approximately 2.1 million gallons per day.-- no,
7 there are 2 at Hudson Falls and 2 at Fort Edwards -- 3 at
8 Hudson Falls which have the 2.1 million gallons per day.
9 But only one of those has been found to contain PCB's on
10 analysis.
11 & Now that one which does contain PCB's, have you '
12 gone back up the pipe, as it were, to find out where the
13 PCB's enter the stream?
.
14 A. We have attempted to -- we have assumed that
15 because there is no process water used in contact with PCB's
16 at Hudson Falls, that these represent a combination of resid
17 uals and of adventitious losses from what is essentially an
18 anhydrous process, and our approach has been to seek out all
19 the possible avenues by which PCB's might get into this non 20 contact water, and block those off.
21 We have also looked to see whether any possible 22 sources of some of the residuals -- we have found some areas
23 that we suspect, and are taking remedial steps with those.
24 But it is not an easy job just to go back up the
Inc.
25 pipeline which has been fed by many different sources of non-
Dsw 315152
STLCOPCB4055617
2729
1 contact water. 2 Q. Well# is it your opinion that the major part of 3 the 20 pounds from Fort Edwards comes from the rinse water,
4 the capacitor rinse water?
5 A. We believe, sir, , that is the major contributor to 6 that one outfall that contains the PCB's.
7 ft Have you been able, similarly,,to identify a major
8 source or major sources of the 10.pounds per day from Hudson
9 Falls?
~
10 A. That is much more of a problem of conjecture,
11 because, as I said, there is no point in the process, as there
12 is at Fort Edward, where we consciously bring water into
13 contact with PCB's.
14 And therefore, as I say, rather than try to go
15 around and identify a particular source, we've gone the other
16 way and said, let's try to close up all possible avenues by
17 which PCB's can escape from a process which is essentially
18 anhydrous and get into a stream of water which had never
19 contained them, because it is never used in processing PCB
20 equipment.
21 Cl Now, in the Pittsfield plant, is any of the 1.86
22 million gallons a day that you've identified as your daily
23 discharge employed in the manufacturing operation directly
24 associated with PCB's?
Inc. V .
25 A. No. And that, by the way, is divided between two
DSW 315153
................................................................... .......................
STLCOPCB4055618
2730
1 distinct outfalls. That's the sum of those two. There are 2 seven outfalls that appear on our permit application. Only
3 two of them have been identified as containing PCB's, and
4 the sum' total of those .two is 1.86.
>
5 Q. And I would ask the same question here as with
6 respect to Fort Edwards and Hudson Falls: has an attempt --
7 this is a ve- ry large amount of water. 1.86 million gallons i
8 per day. Has an attempt been made to analyze the various 9 streams that make, up that, to see which ones do and which
\ !
10 ones do not contain PCB's?
n A. There are so many -- let me back off and give you !
12 some perspective here on this one, too.
13 The Pittsfield plant is about 72 years old. When
14 it was being built up.rover the years since it was first
15 opened, every time a new building would be put up they would
16 run a drain line across the shortest dist ance between that
17 building and the river.
I j
18
The result was a multitude of more than 30 dis-
j
19 charges into the river.
20 When -- and I can't give you the exact date --
21 but when that plant, which..is progressivevand looking at its
22 environmental problems, set up aspecific environmental
;
23 protection operation as part of the facility's operation
24 there, the manager of that set about in a systematic program :
Inc.
25 to consolidate those streams, so that we have now reduced
DSW 315154
'I
......................................
STLCOPCB4055619
2731
1 that down to seven by putting in crosspiping, and so on.
2-
And it would therefore be virtually impossible at
3 this stage, without digging up the whole thing and going
4 underground, to try to pinpoint from which of the myriad of
5 pipes under that plant a particular amount of PCB is coming.
6 Remember, we're talking about only oh the average
7 a tenth of a pound total.
.
8 Ql You have testified that accumulations of PCB's
9 would, result in continued `.discharge, even if the plants were
10 to completely eliminate PCB's from their current operations. 11 What percentage of the discharge could be elimi
12 nated if PCB's were to be eliminated at Pittsfield?
13
A.
If I refer back to these 45 samplings from each
14 of the two discharges over the year 1973, I said the average
15 was about a tenth of a pound per day of 1254, and about .08
16 pounds of 1260.
17 We're assuming that 1260 is a representative of
18 the residuals not of current production art- the one-tenth
19 pound per day average is what represents the losses from 20 current production. That's not a completely strict division, 21 since there have been improvements in the containment process
22 since the date in 1972 when we switched over completely to
23 1254. So there may be a small amount of 1254 in the residu
24 al, but basically 1260 is the residual, 1254 is the current
Inc.
25 production.
DSW 315155
2732
1 ~ & Have you or has anyone under contract to G-E
2 conducted treatability studies for a waste treatment system
3 to remove PCB's?
|
4
A We have approached the problem on the ground that j
'.
i
5 the major priority should be the control of current produc- j
6 tion, and basically all of our environmental control efforts I
7 have been directed towards that.
'i
8 We have been encouraged in that approach by repori
9 memoranda, conversations, with EPA officials during the past
10 few years indicating that EPA's major concern was the control j
j
11 of current losses.
:
12 They recognized that over forty years of use,
' 13 there are going to be lots of PCB's -- quite ubiquitous,
i ;
14 to use the terminology of the interdepartmental task force -- I
15 and that the compelling need was to control the current
16 production. So we have put virtually all of our effort into
17 that, as the desired direction over which we could have some j
j
18 real control and immediate impact.
19 Ql You've referred several times to sampling problems
20 associated with PCB's.
'
21 Could you elaborate on why there are problems
|
j
22 associated with sampling PCB's?
23 A These can arise from several sources. Well, I'm
24
speaking here from information given by our plant people,
,
Inc.
25 because I have not been directly /involved in the sampling.
DSW 315156
, . _ . ..
i
...............................STLCOPCB4055621
2733
1 Let me mention some of these.
j
2 Sampling is generally done through a manhole that
3 presents you with access to the pipe through which the '
j
4 liquid is flowing. We may specify a certain number of gal~ ;
5
Ions a day going through that/ but remember, this is not a
.
:
6 uniform flow. It isn't always flowing at *a constant rate
7 every minute of the day.
8 And secondly, this is water which is noncontact | 9 cooling water which is going through old pipes and may also 10 contain some runoff. So it is not necessarily a clean water,
11 in the sense of being completely free of suspended material,
12 not material that is readily removable by filtration; I'm
13 talking about very fine particles -- which nonetheless can 14 adsorb PCB*s/and. the difference in the analysis could come
15 rom the amount of this material that may come into the
16 grab sample. These are, as I say, grab samples. It's not 17 a continuous sampling of a nice uniform proeess stream 18 which fills the pipe to a given depth all the time.
19 But these are the kind of factors that lead to
20 the wide variability in sampling, as I have been told.
21 Q. Well, now, let's take specifically: V.the flow
22 is not constant. !a.u.\
23 , But over a long series of measurements, wouldn't
24 that tend to average out?
v
Inc.
25 ft. We are talking here about taking a sample, one
DSW 315157
..... ......................... ....... STLCOPCB4055622
2734
1 grab sample a week. Now, I don't know that those samples
2 are taken at precisely the same hour on the came day of the
3 week, and even if they were, I don't know that one would
4 then still guarantee that that-flow would be the same.
-
'
5 But as I say, yes, you say these average out.
j
6 We are reporting an average of 1/10th of a pound per day,but
7
an': excursion can go as high -- the highest value based on
;
8 those 90 measurements gave us a calculated. 0.8'.
.
9
. Qi
Are PCB's adsorbed in water?
10 A Yes.
j
i
|
11 0. So, wouldn't it be possible that they would tend
12 to settle in a stream or in a waste effluent? That is, they
13 v?ould tend to ride down so that a sample taken from the top
14 might contain less PCB's, might it not, than a sample taken
15 at the bottom? 16 A There are undoubtedly differences in the depth
I i i
j
17
from which you measure this. Part of theproblem that
we
i
'
i
18 face in these residuals probably arises precisely from that
19 effect, that the pipes, through which uncontrolled effluents
20 have been going in years past, do contain on their walls
j
21 deposits of PCB's laid down in the fashion you speak of.
22 Q. Do you know what the . solubility'of Aroclor. 101G
23 is?
24 A Not offhand. The most recent value I've seen was Inc. 25 for 1254, and I believe that some of the other -- the Arcslo;
. DSW 315158
................ ............
STLCOPCB4055623
' .
.
i 2735 '
T is, as I recall, on the order of 100 to 200 parts per
n billion. That's the water solubility.
Am
3
Q. So the concentrations that you've measured in
!
4 the effluent, which, as I understand your testimony, were
5 350 and 4,00tf partspar billion for the Hudson Falls and ,
6 Fort Edvards facilities, respectively, are actually well
i| j
j
7 above the limit of solubility, aren't they?
'
8 : A. That is correct. We are- getting this phenomenon
9 thatyou mentioned.
.
i |
10
Some of these are heavier, they get swirled
i
11 around,, and sometimes you find a sample that has a sort of
12 insoluble coagulated PCB.
.
13
14
15
16'
17'
18
19
20
21 22
23
24 Inc. 25
DSW 315159
STLCOPCB4055624
2736
1 Q Now you referred to, as I recall, about 30 pipes 2 discharging into seven outfalls at the Pittsfield plant; is 3 that right?
4 A -' A consolidation of individual discharges into a
5 controllable nuirfber. I may have the actual number. I know
6 seven are reported now.
< * I don't know the number . -
7 historically, but it was considerably larger.
'
8 Q Now wouldn't it be possible to isolate the -- let 9 me ask it a different way:
10 Of two pipes which do contain 'PCBs* two discharges, 11 aren't those two pipes themselves consolidated discharges?; Don'
12 they iead back to other pipes which branch back?
13 A - Lead back in which direction, toward the plant or
14 toward the river?
15 Q Toward the plant?
16 A Yes, they represent the consolidated output of a
17 large network of pipes that are decades old running under
18 buildings that they don't even service. It's a whole maze of
19 drainage systems from in-plant and surface drainage and so forth
20 andv. to get this whole system under control the facilities pcopl
21 said, "Look, we can't just have an uncontrolled number of
22 a couple of dozen discharges. We've got to consolidate this."
23 Because what we have done, you see, is --
Let me tell you
24 some of the reasons why this was done to indicate-that we.: are Inc. 25 not --: this was not to make things -- just to hide things and
DSW 315160
STLCOPCB405562
2737
say we don't know about them, because we only have seven 1
instead of 37. 2
I mentioned that Pyranol is a relatively small 3
fraction of the total operations at Pittsfield. Even 4
transformers are., not the only things--we-make-.at Pittsfield. 5
And the most ubiquitous material is oil, lubricating oils, and 6
cutting oils and so forth, and the environmental people at 7
Pittsfield showed-a commendable initiative and technical 8
resourcefulness in developing a relatively simple but effective 9
oil-water separator. 10
This oil-water separator, just parenthetically, 11
the developers of this received a reward from the National 12
Society of Professional Engineers as one of the ten 13
outstanding engineering achievements in 1972. 14
So it's a good
piece of engineering work. 15
We have installed four of these at outfalls in 16
Pittsfield from which major oil contamination of the river can 17
occur. 18
..
One of the reasons for consolidating all of these 19
drains was so that we could funnel all the water, surface 20
21 runoff, cooling water, everything else, through these, so all
22 of the water that could possibly be contaminated by oil is run
through these oil water separators before it is discharged 23
to the Housatonic River, so this consolidation was done to 24
Inc. control that kind of ubiquitous contamination which is much.
25
DSW 315161
STLCOPCB405562
2738
much larger in terms of quantity than the PCBs.
1 Q Let me see if I understand you correctly.
2 "
When the pipes are run together into the separator,
3 you must be able to identify which pipes go where and is it
4(
my understanding -- is my 'understanding correct that you have
5 not gone back up to these pipes to measure the PCB levels in
6 each?
7 A You have, to visualize, Mr. Eckert, the way this is.
8 You have had a whole network of pipes all underground.
These
9 are drainage pipes; they're not -- all the pipes by which
10 Pyranol or PCBs are transported around the plant are now
11 above ground, so that any leaks that occur are immediately
12 detectable and repairable, but these are drainage pipes for
13 cooling waste . .water, for storm runoff, for everything that
14 we don't need anymore, and these are all underground.
15 Now, what was done some years back--: And\this predate
16 the concern for PCBs as an environmental contaminant.
What
17 was done was to say,
Look, we had all these outfalls going
18 to the river. So they were clearly identified.' What they
19 did was to dig up and put connectors there and send them all
20 to consolidated outfalls and then bury the whole thing again
21 because this is all underground.
:
22 Now we see nothing to be gained by digging all that
23 up and putting individual sample stations on all these,
24 !nc. because we would not even know where these originated from ' 25
DSW 315162
in the plant.
2739
Remember, this is just down where they would
1 terminate at the river we have consolidated them into a
2 common manifold. But even identifying those individual pipes
3 would not identify the sources. V7e know where the current
4 production is located and-our philosophy has been, "Let's
5 stop losses to the best of our ability from those." Anything
6 else that gets in could come from anyplace in the plant,
7 because for 70 years we've moved around production underground
8 facilities and everything else and nobody has detailed records
9 of where everything is in all 70 years of operation.
10 Do you know, you have referred to an incinerator,
11 and the only incinerator GE operates is at Pittsfield; is that
12 correct?
.
13 A The only incinerator that is capable of destroying
14
PCBs, yes.
15 Q Yes.
16
Now, have the emissions from the stack of that
17 incinerator been monitored to determine precisely what they
18
contain?
19 A The emissions from this incinerator have been
20 tested. They are acceptable both to the state and to the
21 EPA. Indeed, we are now just concluding negotiations for a
22 program that was initiated by Region One,: headquartered in...
23 Boston.
24 Inc. 25
They have come and inspected our incinerator
.
. DSW 315163
STLCOPCB4055628
2740
1 facility. They are satisfied that it is an environmentally
i
2 compatible way of destroying PCBs without adding air pollutants.
3 'And they've said:"Look, we havein Hingham, Massachusetts I don'
94 know how many pounds or t ns of DDT that has been pulled off
' .
5 the market as a result of EPA's ban on DDTX and we want to
fc'.' f.
6 get rid of that, and we are convinced that your incinerator
7 provides an environmentally sound way of doing that."
.
8 It was just last week that representatives from 9 Region One and from the state visited our Pittsfield plant
: j
10 for the final negotiations. We have agreed to accept on a
j
11 test basis a certain number of pounds and we will carry out
12 that incineration; if it is satisfactory, we will destroy more.
13 So they are convinced, too, that this is a sound way
14 of disposing of DDT without providing environmental
;
15 contamination.
.j
16 Q Well as I recall, my question was as to the levels '
17 that were measured'in the emissions.
18 A I don't have any data on that specifically. I've
I !
i !
19 been told by the plant people that the emissions do meet the
20 requirements and I am also inclined to believe that when I
|
21 see that EPA has come and said, "Look.--" we did not go out
j
22 to solicit this business; we're not in the business of
!
23 incinerating DDT. We have been asked specifically by EPA to
24 perform this as a service for them.= Inc. 25 In fact, I believe in my testimony I quote from the
DSW 315164
STLCOPCB4055629
ia-6
2741
initial visit on page 3/ in which Dennis Huebner, the Chief of 1
the Solid Waste Program for EPA Region One, sent an unsolicited 2
letter indicating his approval of the process: "The great 3
strides forward in solving the processing of disposal problems 4
of PCS. I'm ve*ry pleased with your willingness to assist 5
Massachusetts in solving some of their hazardous waste disposal 6
problems,particularly the DDT storfed in Hingham, Massachusetts.' 7
We did not ask for that letter. 8
Q On page 10 of your testimony, you refer to the 9
rapid metabolism of the lower chlorinated homologs and you 10
n give a quotation and a Reference 19.
12 In my copy of the testimony, there is no
Reference 19. I wonder if you could tell me what the 13
reference is that you intended to cite there. 14
A That's what happens when documents are put together 15
against a deadline. 16
..
I'm afraid I can't answer unequivocally now. I 17
would have to go back and look at my earlier draft and see 18
that, so I cannot answer that at this sitting. It was 19
obviously a direct quotation and it was from some published 20
paper, but without going back to the original draft. I could 21
not identify it here. 22
*
Q . Has GE done any work to determine the 23
24 ederal Reporters, Inc.
25
biodegradability of PCBs? A No.
' -
DSW 315165
STLCOPCB4055630
2742
1 Q Has GE done any independent work to determine
2 whether or not PCBs are metabolized?
3 A We have relied entirely on the data which others
4 have published and, upon reading it, we have found that it
5 seemed to be data which were properly obtained and reported
6 and we have relied on the scientific ability and integrity
7 of those who have reported it. We have not done any independent
8 work of our own.
9. Q If all of the PCBs which were discharged,from the
10 two plants on the Hudson River were mixed with Hudson River
11 water, have you calculated what the concentration in the
12 Hudson River would be after such mixing?
i
13 A I have not. I have done it for the Housatonic
14 River, because there we had actual measurements and these
15 calculations and measurements were -- I mentioned we had one at 16 three parts per billibn;that' s What ;the calculations would have
17 indicated. Since we didn't have any measurement of the Hudson,
18 I.didn't have the same immediate incentive to do the
19 calculation. I don't know whether Dr. Pozefsky may have done
\
20 that, but I have not. It can be done, based on the 1600 cfs
21 as the flow rate.
,
22 Q Thank you, very much.
23 MR. ECKERT: I don't have any further questions.
24 MR. RICHEL: I have just a few questions. Inc. 25
DSW 315166
..................... .............
......................................
STLCOpCB405563i
2743
' REDIRECT EXAMINATION 1
BY MR. RICHEL: 2
Q A while back, you referred to certain initial 3
limitations for the Hudson Falls facility. I take it those 4
limitations were not the proposed final'limitations .as well? 5
A These were not. These were`for an initial period 6
as defined in the permit. 7
.
Q And the final limitations proposed were? 8
A Zero discharge. 9
Q A while back you also referred to -- what was the 10
11 duration of the permit? Do you recall offhand?
12 A The initial limitations were for a period of
21 months following which the condition was changed to zero 13
discharge for chlorinated hydrocarbons. 14
Q And the duration of the permit entirely was five 15
years? 16
A I-would, have to check that point. 17
Yes. The initial period was 21 months, the total 18
five years, yes. 19
20 Q Now you also referred at one point a while ago to
21 the concept of zero containment. I just want to make sure
22 there that it reads properly.
Am I correct in assuming that zero containment 23
24 is the equivalent of a hundred percent containment?
inc. 25 A Thank you for.correcting that. I mean containment
DSW 315167
..
2744
from which the losses are directed as low as possible toward
1 zero.
2
Q
Just one other point. :*. "
*.v', '-. i.
3
Mr. Eckert touched upon the company's manufacture
4
of transformers>for railroad applications.
5
Where is that done?
A Pittsfield.
6
Q Is it also done at Erie?
7
A Erie manufactures the cars and they purchase 8
transformers from Pittsfield and install them on the cars 9
that they manufacture at Erie.
10
Q And has Erie received any inquiries from
11
.
representatives of operating railroads and representatives
12
of the Department of Transportation and the Department of 13
Commerce concerning the application of this proposed standard? 14
A The Department of Transportation and the Department 15
of Commerce and major railroads, particularly in the Northeast, 16
have expressed great concern over the continued availability 17
of PCB-filled transformers for mass transit operation. 18
Q Very simply, without a long dissertation, what's 19
the problem?
20
A With them getting it? Or vzhy they use it?
21
;
Q What's the problem if they can't get it any further?
22
A Flammability.. These are mounted underneath the 23
cars on which passengers ride. If there should be any mal-' 24 %
Inc. function of the transformer or any rupture of the transformer, 25
DSW 315168
STLCOPCB4055633
. 2745 allowing liquid to leave it, as through an accident, if that
1
liquid is oil there is immediately a fire hazard endanger
2
ing the safety of lives of the passengers.
3
Q To your knowledge, has this problem been
4
considered by EPA?
'
.
-
5
A I've seen no evidence that EPA has considered this.
6 MR. RICHEL: I don't have any other questions.
7
RECROSS EXAMINATION
8 BY MR. ECKERT:
j
I
9
Q Does GE intend to attain zero discharge at the two
10
plants on the Hudson River?
n A Zero discharge as it appears in the Federal Water
12 Pollution Control Act is a national goal. And --
13
Q Well, I'm referring to the proposed permit condition
14
which Mr. Richel questioned you about.
15
A Oh. We have filed a formal objection on grounds
16
that I'm sure Mr. Richel, who wrote the letter, could explain
17
in more legal terms than I. Whom of us do you wish to answer
.18
that, because we feel there was an improper imposition of a
19
condition in the permit which was not justified either in
20 terms of timing, or certainly even in terms of the proposed
21
regulations? The proposed regulations would not set zero
22
discharge into a river flowing at 1600 cubic feet per second.
23
MR. RICHEL: Let me just say that in this instance,
24 %
Inc. as with one other recent instance, we felt regional
25
DSW 315169
STLCOPCB4055634
2746
EPAs were attempting to prematurely impose toxic pollutant 1
standards for the sake of administrative convenience.
2
That
principle was acknowledged by Region Four recently, and we're 3
hoping that that same principle will be acknowledged by 4
I |
Region Two; and^therefore will not impose zero discharge 5
limitation as being representative of best practicable
6
technology. 7
i
BY MR. ECKERT:
8
Q Are there alternative diaelec'trics for. PCKs in ; 9 '`
transformers for railroad use0 10
A The use of PCBs in . transformers is dictated 11
.
j
I
:j
j
|
12 exclusively by the safety factor that it imparts to the
!
equipment. 13
From an electrical point of view, mineral oil would
do just as well. 14
It would be cheaper for us and for the
customer. 15
It would provide a transformer that was lighter in
weight. It would provide a transformer which would not require 16
some of the special insulation that is required inside of 17
PCB-filled transformers. 18
There has therefore been ever since we got into this 19
20 business all of the traditional economic incentives for us to
21 find a substitute material. And over the last 30 years, more
22 than a hundred possible substitutes for PCBs have been looked
at in the laboratory for use in transformers. 23
That effort has been accelerated within the'past 24
Inc 25 year, since the first indication that these regulations might
. DSW 315170
STLCOPCB4055635
2747
appear as stringent as they have been published. And to date 1
v/e see nothing that would combine the electrical and safety
2
characteristics of PCBs. 3
Q Thank you, Dr. Simons.
.
4
MR. ECKERT: I don't have any further questions. 5
JUDGE SWEENEY: You're excused, sir.
6
(Witness excused.)
7
JUDGE SWEENEY: We'll take a 15-minute recess.
8
(Recess.) 9
10
11
12
13
14
15 16
17
18
19
20
21
22
23
24 Inc. 25
DSW 315171
STLCOPCB4055636